Common use of Photometric requirements Clause in Contracts

Photometric requirements. When so adjusted, the front fog lamp shall meet the photometric requirements in the table below (refer also to paragraph 2.2. of Annex 4 to this Regulation): Designated lines or zones Vertical position* above h + below h - Horizontal position* left of v: - right of v: + Luminous intensity (in cd) To comply Point 1, 2** +60° ±45° 85 max All points Point 3, 4** +40° ±30° Point 5, 6** +30° ±60° Point 7, 10** +20° ±40° Point 8, 9** +20° ±15° Line 1** +8° -26° to +26° 130 max All line Line 2** +4° -26° to +26° 150 max All line Line 3 +2° -26° to +26° 245 max All line Line 4 +1° -26° to +26° 360 max All line Line 5 0° -10° to +10° 485 max All line Line 6 *** -2.5° -10° to +10° 2,000 min All line Line 7 *** -6.0° -10° to +10° < 50 per cent of max. on line 6 All line Line 8L and R*** -1.5° to -3.5° -22° and +22° 1,100 min One or more points Line 9L and R*** -1.5° to -4.5° -35° and +35° 450 min One or more points Zone D*** -1.5° to -3.5° -10° to +10° 12,000 max Whole zone * The co-ordinates are specified in degrees for an angular web with a vertical polar axis. ** See paragraph 6.4.3.4. *** See paragraph 6.4.3.2.

Appears in 4 contracts

Samples: unece.org, unece.org, unece.org

AutoNDA by SimpleDocs

Photometric requirements. When so adjusted, the front fog lamp shall meet the photometric requirements in the table below Table 36 (refer also to paragraph 2.2. Figure A4-XI of Annex 4 to this Regulation4): Table 36 Type approval photometric requirements for front fog lamp Designated lines or zones Vertical position* above h + below h - Horizontal position* left of v: - right of v: + Luminous intensity (in cd) To comply Point 1, 2** +60° ±45° 85 max All points Point 3, 4** +40° ±30° Point 5, 6** +30° ±60° Point 7, 10** +20° ±40° Point 8, 9** +20° ±15° Line 1** +8° -26° to +26° 130 max All line Line 2** +4° -26° to +26° 150 max All line Designated lines or zones Vertical position* above h + below h - Horizontal position* left of v: - right of v: + Luminous intensity (in cd) To comply Line 3 +2° -26° to +26° 245 max All line Line 4 +1° -26° to +26° 360 max All line Line 5 0° -10° to +10° 485 max All line Line 6 *** -2.5° -10° to +10° 2,000 2700 min All line Line 7 *** -6.0° -10° to +10° < 50 per cent of max. on line 6 All line Line 8L and R*** -1.5° to -3.5° -22° and +22° 1,100 min One or more points Line 9L and R*** -1.5° to -4.5° -35° and +35° 450 min One or more points Zone D*** -1.5° to -3.5° -10° to +10° 12,000 max Whole zone Notes to Table 36 * The co-ordinates are specified in degrees for an angular web with a vertical polar axis. ** See paragraph 6.4.3.45.5.2.4. *** See paragraph 6.4.3.25.5.2.2.

Appears in 2 contracts

Samples: unece.org, www.unece.org

Photometric requirements. When so adjusted, the front fog lamp shall meet the photometric requirements in the table below Table 36 (refer also to paragraph 2.2. Figure A4-XI of Annex 4 to this Regulation4): Table 36 Type approval photometric requirements for front fog lamp Designated lines or zones Vertical position* above h + below h - Horizontal position* left of v: - right of v: + Luminous intensity (in cd) To comply Point 1, 2** +60° ±45° 85 max All points Point 3, 4** +40° ±30° Point 5, 6** +30° ±60° Point 7, 10** +20° ±40° Point 8, 9** +20° ±15° Line 1** +8° -26° to +26° 130 max All line Line 2** +4° -26° to +26° 150 max All line Line 3 +2° -26° to +26° 245 max All line Line 4 +1° -26° to +26° 360 max All line Line 5 0° -10° to +10° 485 max All line Line 6 *** -2.5° -10° to +10° 2,000 2700 min All line Line 7 *** -6.0° -10° to +10° < 50 per cent of max. on line 6 All line Line 8L and R*** -1.5° to -3.5° -22° and +22° 1,100 min One or more points Line 9L and R*** -1.5° to -4.5° -35° and +35° 450 min One or more points Zone D*** -1.5° to -3.5° -10° to +10° 12,000 max Whole zone Notes to Table 36 * The co-ordinates are specified in degrees for an angular web with a vertical polar axis. ** See paragraph 6.4.3.45.5.2.4. *** See paragraph 6.4.3.25.5.2.2.

Appears in 2 contracts

Samples: unece.org, unece.org

Photometric requirements. When so adjusted, the front fog lamp shall meet the photometric requirements in the table below (refer also to Annex 4, paragraph 2.2. of Annex 4 to this Regulation): Designated lines or zones Vertical position* above h + below h - Horizontal position* left of v: - right of v: + Luminous intensity (in cd) To comply Point 1, 2** +60° ±45° 85 max All points Point 3, 4** +40° ±30° Point 5, 6** +30° ±60° Point 7, 10** +20° ±40° Point 8, 9** +20° ±15° Line 1** +8° -26° to +26° 130 max All line Line 2** +4° -26° to +26° 150 max All line Line 3 +2° -26° to +26° 245 max All line Line 4 +1° -26° to +26° 360 max All line Line 5 0° -10° to +10° 485 max All line Line 6 6*** -2.5° -10from 5° inwards to +1010° 2,000 outwards 2,700 min All line Line 7 7*** -6.0° -10from 5° inwards to +1010° outwards < 50 per cent of max. on line 6 All line Line 8L and R*** -1.5° to -3.5° -22° and +22° 1,100 min One or more points Line 9L and R*** -1.5° to -4.5° -35° and +35° 450 min One or more points Zone D*** -1.5° to -3.5° -10° to +10° 12,000 max Whole zone * The co-ordinates are specified in degrees for an angular web with a vertical polar axis. ** See paragraph 6.4.3.4. *** See paragraph 6.4.3.2.

Appears in 1 contract

Samples: unece.org

AutoNDA by SimpleDocs

Photometric requirements. When so adjusted, the front fog lamp shall meet the photometric requirements in the table below (refer also to paragraph 2.2. of Annex 4 to this Regulation): Designated lines or zones Vertical position* above h + below h - Horizontal position* left of v: - right of v: + Luminous intensity (in cd) To comply Point 1, 2** +60° ±45° 85 60 max All points Point 3, 4** +40° ±30° Point 5, 6** +30° ±60° Point 7, 10** +20° ±40° Point 8, 9** +20° ±15° Line 1** +8° -26° to +26° 130 90 max All line Line 2** +4° -26° to +26° 150 105 max All line Line 3 +2° -26° to +26° 245 170 max All line Line 4 +1° -26° to +26° 360 250 max All line Line 5 0° -10° to +10° 485 340 max All line Line 6 6*** -2.5° -10° to +10° 2,000 2,700 min All line Line 7 7*** -6.0° -10° to +10° < 50 per cent % of max. on line 6 All line Line 8L and R*** -1.5° to -3.5° -22° and +22° 1,100 800 min One or more points Designated lines or zones Vertical position* above h + below h - Horizontal position* left of v: - right of v: + Luminous intensity (in cd) To comply Line 9L and R*** -1.5° to -4.5° -35° and +35° 450 320 min One or more points Zone D*** -1.5° to -3.5° -10° to +10° 12,000 8,400 max Whole zone * The co-ordinates are specified in degrees for an angular web with a vertical polar axis. ** See paragraph 6.4.3.4. below. *** See paragraph 6.4.3.2. below.

Appears in 1 contract

Samples: www.unece.org

Time is Money Join Law Insider Premium to draft better contracts faster.