Physical Connections. The customer interfaces to the ATM Transport through DS3 (un-channelized), OC-3c or OC-12c interfaces
AutoNDA by SimpleDocs

Related to Physical Connections

  • Electrical connections Equipment requiring electrical connections for operation shall either be hard wired to the Authorized User's provided connections or the Contractor shall be responsible for a male electrical union. All connections shall be made by the Contractor and accomplished in accordance with National Electrical Code requirements. Electrically operated equipment shall be available in the following volts and phases: 208 volt 1 or 3 phase, 60 HZ 220 volt 1 or 3 phase, 60 HZ 440 volt 1 or 3 phase, 60 HZ

  • Connections HTC”s responsibility for service ends at the demarcation point. “Demarcation” means the point of meeting where the “hand-off” occurs between HTC’s system and Customer’s system. Facilities used by HTC in providing Services may be connected with terminal equipment or communications systems provided by Customer. In such a case, facilities and terminal equipment or communications systems provided by Customer or its customers shall be subject to mutually agreeable technical interface specifications.

  • Internet Connection Certain Solutions may require an active and stable connection to the Internet in order to function. It is therefore your responsibility to ensure that you have at all times an active and stable Internet connection.

  • Physical Condition Except as disclosed in the Physical Conditions Reports delivered to Lender in connecting with this Loan, to Borrower's knowledge, the Property, including, without limitation, all buildings, improvements, parking facilities, sidewalks, storm drainage systems, roofs, plumbing systems, HVAC systems, fire protection systems, electrical systems, equipment, elevators, exterior sidings and doors, landscaping, irrigation systems and all structural components, are in good condition, order and repair in all material respects; there exists no structural or other material defects or damages in the Property, whether latent or otherwise, and Borrower has not received notice from any insurance company or bonding company of any defects or inadequacies in the Property, or any part thereof, which would adversely affect the insurability of the same or cause the imposition of extraordinary premiums or charges thereon or of any termination or threatened termination of any policy of insurance or bond.

  • Cross Connection For a collocation arrangement, the facilities between the collocating Party’s equipment and the equipment or facilities of the housing Party (such as the housing Party’s digital signal cross connect, Main Distribution Frame, or other suitable frame or panel).

  • Access Toll Connecting Trunk Group Architecture 9.2.1 If CSTC chooses to subtend a Verizon access Tandem, CSTC’s NPA/NXX must be assigned by CSTC to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG. 9.2.2 CSTC shall establish Access Toll Connecting Trunks pursuant to applicable access Tariffs by which it will provide Switched Exchange Access Services to Interexchange Carriers to enable such Interexchange Carriers to originate and terminate traffic to and from CSTC’s Customers. 9.2.3 The Access Toll Connecting Trunks shall be two-way trunks. Such trunks shall connect the End Office CSTC utilizes to provide Telephone Exchange Service and Switched Exchange Access to its Customers in a given LATA to the access Tandem(s) Verizon utilizes to provide Exchange Access in such LATA. 9.2.4 Access Toll Connecting Trunks shall be used solely for the transmission and routing of Exchange Access to allow CSTC’s Customers to connect to or be connected to the interexchange trunks of any Interexchange Carrier which is connected to a Verizon access Tandem.

  • Physical Collocation (a) If space for Physical Collocation is immediately available at the time of Requesting Carrier’s Collo Order, Ameritech shall include in its Collo Response to Requesting Carrier notice of such immediate availability. (b) If Requesting Carrier’s requested Physical Collocation space is available, Ameritech and Requesting Carrier shall have an initial walk-through of such space within the interval specified in the Implementation Plan. Absent Ameritech’s written consent, Requesting Carrier must have at least one (1) authorized employee (i.e., in addition to any authorized vendor) at such walk- through. If during the initial walk-through, Requesting Carrier wishes to modify or change its Collo Request, Requesting Carrier must sign or initial any such modifications or changes and provide Ameritech a change order reflecting same within five (5) Business Days of such initial walk-through. If a change or modification is noted at the initial walk-through, Ameritech shall have no obligation to commence work on Requesting Carrier’s Collocation space until it receives a change order to amend the Collo Request or written confirmation that Requesting Carrier does not wish to pursue such change or modification. Failure to provide Ameritech the change order or written confirmation within the foregoing five (5) Business Day period shall be deemed a Requesting Carrier Delaying Event for the period between the expiration of such five (5) day period and the date of actual receipt by Ameritech. (c) Ameritech shall deliver to Requesting Carrier the requested space on or before the later of (i) one hundred twenty (120) days from Ameritech’s receipt of Requesting Carrier’s Collo Order, (ii) ninety (90) days from the date of the initial walk-through and (iii) such other reasonable date that the Parties may agree upon if it is not feasible for Ameritech to deliver to Requesting Carrier such space within the foregoing intervals (such date of delivery referred to as the “Delivery Date”). (d) Physical Collocation space ordered by Requesting Carrier will be made available to Requesting Carrier by Ameritech as more fully described in Section 1 of Schedule 12.12. (e) Ameritech may begin billing recurring charges for the Collocated space on the date such space is made available for occupancy (the “Occupancy Date”). Requesting Carrier shall vacate the Collocated space if either (i) Requesting Carrier (or one of its Resident Collocators, if applicable) fails to install within ninety (90) days of the Occupancy Date the equipment necessary for Interconnection with Ameritech and/or access to Ameritech’s unbundled Network Elements to be housed in such space or (ii) Requesting Carrier (or one of its Resident Collocators, if applicable) fails to Interconnect to the Ameritech network within one hundred fifty (150) days of the Occupancy Date. If Requesting Carrier is required to vacate the space pursuant to this Section 12.12.2(e), Requesting Carrier (and its Resident Collocators) shall vacate such space within ninety (90) Business Days of the earliest to occur of the foregoing events. If, after vacating a space, Requesting Carrier still requires Collocation in that Premises, Requesting Carrier shall be required to submit a new request for Collocation pursuant to the provisions of Section 12.12.1. (f) Physical Collocation will be subject to the additional rules and regulations set forth in Section 2.0 of Schedule 12.12. (g) At Requesting Carrier’s request Ameritech shall provide for APCS within three

  • Delivery of Materials In the event of any expiration or termination of this Agreement, Contractor shall promptly provide the JBE with all originals and copies of the Deliverables, including any partially-completed Deliverables-related work product or materials, and any JBE-provided materials in its possession, custody, or control. In the event of any termination of this Agreement, the JBE shall not be liable to Contractor for compensation or damages incurred as a result of such termination; provided that if the JBE’s termination is not for cause, the JBE shall pay any fees due under this Agreement for Services performed or Deliverables completed and accepted as of the date of the JBE’s termination Notice.

  • Reconnection The Parties shall cooperate with each other to restore the Small Generating Facility, Interconnection Facilities, and the New York State Transmission System and Distribution System to their normal operating state as soon as reasonably practicable following a temporary disconnection.

  • Topographic Survey The Professional shall obtain a topographic and utility survey as described below. 4.1.1. The Professional shall tie in all existing surface topographic features and structures within the survey limits shown in Figure 1. This survey shall include: tops of curbs, edges of pavement, pavement materials, driveways, sidewalks, retaining walls, drainage structures (top, edges and flow line), channels and drainage ways (tops, toes and flow line), manholes (rim, flow lines and diameters of pipes, type of material and photographs of the inside of manholes and drainage structures), including the same survey data for upstream and downstream manholes and structures that are outside of the survey limits for all gravity wastewater and drainage lines within the survey limits. Visible valves, meters, clean-outs, slabs, utility signs, utility poles and structures, fences, landscaping features, shrubbery, trees (including the approximate drip-line), tree canopies, buildings (edges within the survey limits) mailboxes, etc. Trees shall be tagged and tabulated by size and species specific in compliance with the City of New Braunfels Tree Preservation ordinance as defined in the City of New Braunfels Zoning Ordinance Chapter 5.3- 5i. The survey limits shall extend approximately 100 feet on intersecting streets. The Professional shall provide sufficient ground shots to create one (1) foot contours for the Project. 4.1.2. The Professional shall conduct a utility survey and locate existing utilities within the Project boundary in Figure 1. The Professional shall contact all utility service providers by calling Texas 811 and the NBU Project Manager to coordinate flagging of existing franchise utilities. The Professional shall request drawings of existing agency and municipal owned utilities and shall include locations of these utilities in the survey. The Professional shall tie in the locations of the discovered utilities on the survey. The Professional shall bear all costs for the Services associated with utility locates. 4.1.3. The Professional shall locate up to ten (10) geotechnical borings and tie them in to the Project survey. 4.1.4. The Professional shall set and install control points and/or benchmarks as required for the survey work (minimum 1-foot intervals). The Professional shall provide horizontal and vertical coordinates of the benchmarks in the required coordinate system and datum and show the benchmarks on the survey drawing. 4.1.5. The Professional shall research and review adjoining plats and deeds along the survey corridor. The Professional shall locate property corners and identify existing right of way (“ROW”), along the survey corridor, based on found monuments and record documents.