Common use of Plant Inlet Specifications Clause in Contracts

Plant Inlet Specifications. Shipper shall be required to comply with the Gas Specifications, Notwithstanding these Gas Specifications, the Parties acknowledge and agree that if Gas exceeds (i) six percent (6%) CO2 or (ii) over twenty parts per million (20 ppm) H2S at the Plant inlets (“Plant Inlet Specifications”), then the capacity of such Plants may be reduced. In such event, Gatherer shall use commercially reasonable efforts to blend Shipper Gas with other Gas available on the Olympia Gathering System to comply with the Plant Inlet Specifications. Notwithstanding the provisions of Section 3.3 of the General Terms and Conditions, in the event that (i) Gatherer is unable to blend Shipper Gas to comply with the Plant Inlet Specifications up to the capacity of the Initial Build Conditions, (ii) Gatherer is not able to obtain consents from the Shipper and any other Preferential Capacity Shippers to make necessary and reasonable adjustments to bring the Gas within the Plant Inlet Specifications and (iii) Plant capacity is reduced, then Gatherer shall curtail Gas in the following order: (x) Gas delivered by third party shippers and (y) Gas from a particular Receipt Point or Points not meeting the Plant Inlet Specifications, provided that in the event that more than one Receipt Point has Gas that exceeds the Plant Inlet Specifications, the Receipt Point containing the greatest amount of CO2 and H2S will be curtailed first The Parties acknowledge and agree that no breach of this Agreement shall occur, and no penalty or termination right is created, when the capacity of a particular Plant is reduced when Shipper delivers Gas to the Receipt Points that does not meet the Plant Inlet Specifications to the extent, and only to the extent, that the delivery of such Gas causes the reduction in capacity of the applicable Plant. If Additional Services are provided pursuant to Section 7. with respect to the Gas Specifications, Gatherer and Shipper shall amend the Plant Inlet Specifications as necessary to take into account the Additional Services.

Appears in 2 contracts

Samples: Gas Gathering and Treating Agreement (Vine Resources Inc.), Gas Gathering and Treating Agreement (Vine Resources Inc.)

AutoNDA by SimpleDocs

Plant Inlet Specifications. Shipper shall be required to comply with the Gas Specifications, . Notwithstanding these Gas Specifications, the Parties acknowledge and agree that if Gas exceeds (i) six five percent (65%) CO2 or (ii) over twenty parts per million (20 ppm) H2S at the Plant inlets (“Plant Inlet Specifications”), then the capacity of such Plants may be reduced. In such event, Gatherer shall use commercially reasonable efforts to blend Shipper Gas with other Gas available on the Olympia Magnolia Gathering System to comply with the Plant Inlet Specifications. Notwithstanding the provisions of Section 3.3 of the General Terms and Conditions, in the event that (i) Gatherer is unable to blend Shipper Gas to comply with the Plant Inlet Specifications up to the capacity of the Initial Build Conditions, (ii) Gatherer is not able to obtain consents from the Shipper and any other Preferential Capacity Shippers to make necessary and reasonable adjustments to bring the Gas within the Plant Inlet Specifications and (iii) Plant capacity is reduced, then Gatherer shall curtail Gas in the following order: (x) Gas delivered by third party shippers and (y) Gas from a particular Receipt Point or Points not meeting the Plant Inlet Specifications, provided that in the event that more than one Receipt Point has Gas that exceeds the Plant Inlet Specifications, the Receipt Point containing the greatest amount of CO2 and H2S will be curtailed first first. The Parties acknowledge and agree that no breach of this Agreement shall occur, and no penalty or termination right is created, when the capacity of a particular Plant is reduced when Shipper delivers Gas to the Receipt Points that does not meet the Plant Inlet Specifications to the extent, and only to the extent, that the delivery of such Gas causes the reduction in capacity of the applicable Plant. If Additional Services are provided pursuant to Section 7. , with respect to the Gas Specifications, Gatherer and Shipper shall amend the Plant Inlet Specifications as necessary to take into account the Additional Services.

Appears in 2 contracts

Samples: Gas Gathering and Treating Agreement (Vine Resources Inc.), Gas Gathering and Treating Agreement (Vine Resources Inc.)

AutoNDA by SimpleDocs
Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!