Primary Frequency Response Developer shall ensure the primary frequency response capability of its Large Generating Facility by installing, maintaining, and operating a functioning governor or equivalent controls. The term “functioning governor or equivalent controls” as used herein shall mean the required hardware and/or software that provides frequency responsive real power control with the ability to sense changes in system frequency and autonomously adjust the Large Generating Facility’s real power output in accordance with the droop and deadband parameters and in the direction needed to correct frequency deviations. Developer is required to install a governor or equivalent controls with the capability of operating: (1) with a maximum 5 percent droop ± 0.036 Hz deadband; or (2) in accordance with the relevant droop, deadband, and timely and sustained response settings from an approved Applicable Reliability Standard providing for equivalent or more stringent parameters. The droop characteristic shall be: (1) based on the nameplate capacity of the Large Generating Facility, and shall be linear in the range of frequencies between 59 and 61 Hz that are outside of the deadband parameter; or (2) based on an approved Applicable Reliability Standard providing for an equivalent or more stringent parameter. The deadband parameter shall be: the range of frequencies above and below nominal (60 Hz) in which the governor or equivalent controls is not expected to adjust the Large Generating Facility’s real power output in response to frequency deviations. The deadband shall be implemented: (1) without a step to the droop curve, that is, once the frequency deviation exceeds the deadband parameter, the expected change in the Large Generating Facility’s real power output in response to frequency deviations shall start from zero and then increase (for under-frequency deviations) or decrease (for over-frequency deviations) linearly in proportion to the magnitude of the frequency deviation; or (2) in accordance with an approved Applicable Reliability Standard providing for an equivalent or more stringent parameter. Developer shall notify NYISO that the primary frequency response capability of the Large Generating Facility has been tested and confirmed during commissioning. Once Developer has synchronized the Large Generating Facility with the New York State Transmission System, Developer shall operate the Large Generating Facility consistent with the provisions specified in Articles 9.5.5.1 and 9.5.5.2 of this Agreement. The primary frequency response requirements contained herein shall apply to both synchronous and non-synchronous Large Generating Facilities.
Incident Response Operator shall have a written incident response plan that reflects best practices and is consistent with industry standards and federal and state law for responding to a data breach, breach of security, privacy incident or unauthorized acquisition or use of any portion of Data, including PII, and agrees to provide LEA, upon request, an executive summary of the written incident response plan.
Workplace Violence Prevention and Crisis Response (applicable to any Party and any subcontractors and sub-grantees whose employees or other service providers deliver social or mental health services directly to individual recipients of such services): Party shall establish a written workplace violence prevention and crisis response policy meeting the requirements of Act 109 (2016), 33 VSA §8201(b), for the benefit of employees delivering direct social or mental health services. Party shall, in preparing its policy, consult with the guidelines promulgated by the U.S. Occupational Safety and Health Administration for Preventing Workplace Violence for Healthcare and Social Services Workers, as those guidelines may from time to time be amended. Party, through its violence protection and crisis response committee, shall evaluate the efficacy of its policy, and update the policy as appropriate, at least annually. The policy and any written evaluations thereof shall be provided to employees delivering direct social or mental health services. Party will ensure that any subcontractor and sub-grantee who hires employees (or contracts with service providers) who deliver social or mental health services directly to individual recipients of such services, complies with all requirements of this Section.
Child Support Obligation Under Section 231.006(d) of the Texas Family Code regarding child support, Contractor certifies that the individual or business entity named in this Contract and any related Solicitation Response is not ineligible to receive the specified payment and acknowledges that the Contract may be terminated and payment may be withheld if this certification is inaccurate. If the certification is shown to be false, Contractor may be liable for additional costs and damages set out in 231.006(f).
Payment Responsibility The payment obligations of each Participating Manufacturer pursuant to this Agreement shall be the several responsibility only of that Participating Manufacturer. The payment obligations of a Participating Manufacturer shall not be the obligation or responsibility of any Affiliate of such Participating Manufacturer. The payment obligations of a Participating Manufacturer shall not be the obligation or responsibility of any other Participating Manufacturer. Provided, however, that no provision of this Agreement shall waive or excuse liability under any state or federal fraudulent conveyance or fraudulent transfer law. Any Participating Manufacturer whose Market Share (or Relative Market Share) in any given year equals zero shall have no payment obligations under this Agreement in the succeeding year.
Client Responsibility For clarity, the parties agree that in reviewing the documents referred to in clause (b) above, Patheon’s role will be limited to verifying the accuracy of the description of the work undertaken or to be undertaken by Patheon. Subject to the foregoing, Patheon will not assume any responsibility for the accuracy of any application for receipt of an approval by a Regulatory Authority. The Client is solely responsible for the preparation and filing of the application for approval by the Regulatory Authority and any relevant costs will be borne by the Client.
Emergency Response Partners must develop, maintain, and carry out a response plan for public water system emergencies, including disease outbreaks, spills, operational failures, and water system contamination. Partners must notify DWS in a timely manner of emergencies that may affect drinking water supplies.
Administrative Support Service Fees Within forty-five (45) days of the end of each calendar quarter, the Fund will make payments in the aggregate amount of 0.0625% (0.25% on an annual basis) of the average during that calendar quarter of the aggregate net asset value of the Shares computed as of the close of each business day (the "Service Fee"). Such Service Fee payments received from the Fund will compensate the Distributor for providing administrative support services with respect to Accounts. The administrative support services in connection with Accounts may include, but shall not be limited to, the administrative support services that a Recipient may render as described in Section 3(b)(i) below.
Security Incident Response Upon becoming aware of a Security Incident, MailChimp shall notify Customer without undue delay and shall provide timely information relating to the Security Incident as it becomes known or as is reasonably requested by Customer.
Administrative Support Services Fees Within forty-five (45) days of the end of each calendar quarter or at such other period as deemed appropriate by the Distributor, the Fund will make payments in the aggregate amount of up to 0.25% on an annual basis of the average during the period of the aggregate net asset value of the Shares computed as of the close of each business day (the “Service Fee”). Such Service Fee payments received from the Fund will compensate the Distributor for providing administrative support services with respect to Accounts. The administrative support services in connection with Accounts may include, but shall not be limited to, the administrative support services that a Recipient may render as described in Section 3(b)(i) below.