Common use of Protection Options Clause in Contracts

Protection Options. Protection Option Description Minimum Location Requirements Space Power Environ mental Control Back Up Power (1) (2) (4) Not applicable Protection (Level AA) 2 Level AA Protection means the Product is provided over two (2) separate fiber paths, one of which is the working (primary) path and the other the protect (secondary) path. Company is responsible for managing the Failover Switching between the working and protect paths. Level AA Protection consists of the following minimum requirements at each Location: (i) a single point of entry into the Location; (ii) one (1) Company Equipment chassis; (iii) one (1) port; and (iv) a 2-fiber handoff to Licensee from the Company Equipment. (1) (2) (4) (6) Protection (Level AAA) 3 Level AAA Protection means the Product is provided over two (2) wavelengths utilizing separate fiber paths, one of which is the working (primary) path and the other the protect (secondary) path. Failover Switching at each Location will be provided by Licensee or by Company as specified in the Order Form. Level AAA Protection consist of the following minimum requirements at each Location: (i) two (2) separate points of entry into the Location; (ii) two (2) Company Equipment chassis; (iii) one (1) line card per chassis; (iv) a 4-fiber handoff to the Licensee from the Company Equipment, with two fibers handed off from one of the Company Equipment chassis and two fibers handed off from the other Company Equipment chassis. (1) (3) (5) (7) (1) Secure space for Company Equipment at each Location with 24x7x365 access. (2) Dedicated electrical circuit for Company Equipment from the public utility. (i.e., the circuit has no other load from the Company Equipment to a circuit breaker) at each Location. (3) Redundant, dedicated electrical circuit at each Location from the public utility (i.e. each power circuit is fed from a different circuit breaker panel and has its own circuit breaker) (4) Substantially dust free with temperature control that maintains temperature between 50 and 80-deg F and humidity control that maintains relative humidity below 80%. (5) Substantially dust free with temperature control that maintains temperature between 60 and 80-deg F and humidity control that maintains relative humidity between 40% and 60% (6) Company (or Licensee if the Parties agree) to install and maintain a minimum of four (4) hours of standby power (7) Company (or Licensee if the Parties agree) to install and maintain a minimum of eight (8) hours of standby power and Licensee shall provide emergency power generation

Appears in 2 contracts

Samples: Telecommunications License Agreement, Telecommunications License Agreement

AutoNDA by SimpleDocs

Protection Options. Protection Option Description Minimum Location Requirements Space Power Environ mental Environmental Control Back Up Power (1) (2) (4) Not applicable Optical Protection (Level AAAA Access) 2 Level AA Protection Access means the Product access portion of the Ethernet (i.e. the segments from the last Company Network switching hub to the point of entry of the Location) is provided over two (2) separate fiber paths, one of which is the working (primary) path and the other the protect (secondary) path. Company is responsible for managing the Failover Switching between the working and protect pathsat each Location. Level AA Protection consists of the following minimum requirements at each Location: (i) a single point of entry into the Location; (ii) one (1) Company Equipment chassis; (iii) one (1) port; and (iv) a 2-fiber handoff to the Licensee from the Company Equipment. (1) (2) (4) (6) Dual Path Protection (Level AAA) 3 Level AAA Protection Access means the Product access portion of the Ethernet (i.e. the segments from the last Company Network switching hub to the point of entry of the Location) is provided over two (2) wavelengths utilizing separate fiber paths, one of which is the working (primary) path and the other the protect (secondary) path. Failover Switching at each Location will be provided by Licensee or by Company as specified in the Order Form. Level AAA Protection consist of the following minimum requirements at each Location: (i) two (2) separate points of entry into the Location; (ii) two (2) Company Equipment chassis; (iii) one (1) line card per chassis; (iv) a 4-fiber handoff to the Licensee from the Company Equipment, with two fibers handed off from one of the Company Equipment chassis and two fibers handed off from the other Company Equipment chassis; and (v) Licensee Equipment must have dual-card redundancy (i.e., separate cards, one for one of the 2-fiber handoffs and the other for the second 2-fiber handoff). (1) (3) (5) (7) (1) Secure space for Company Equipment at each Location with 24x7x365 access. (2) Dedicated electrical circuit for Company Equipment from the public utility. (i.e., i.e. the circuit has no other load from the Company Equipment to a circuit breaker) at each Location. (3) Redundant, dedicated electrical circuit at each Location from the public utility (i.e. each power circuit is fed from a different circuit breaker panel and has its own circuit breaker) (4) Substantially dust free with temperature control that maintains temperature between 50 and 80-deg F and humidity control that maintains relative humidity below 80%utility. (5) Substantially dust free with temperature control that maintains temperature between 60 and 80-deg F and humidity control that maintains relative humidity between 40% and 60% (6) Company (or Licensee if the Parties agree) to install and maintain a minimum of four (4) hours of standby power (7) Company (or Licensee if the Parties agree) to install and maintain a minimum of eight (8) hours of standby power and Licensee shall provide emergency power generation

Appears in 2 contracts

Samples: Telecommunications License Agreement, Telecommunications License Agreement

AutoNDA by SimpleDocs
Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!