Radiography test. (As per clause no. 4.16 of spec): Sample size: one or 5% of the lot whichever is more. The radiography examination shall be as per ▇▇▇▇-▇ ▇▇▇ ▇▇▇▇▇-▇▇. Location of radiography test should be as per annexure –F, G & H of specification MP-0.41.00.05
Radiography test. 100% radiography shall be carried out on all casting. Radiography procedure and area of casting to be radiographed shall be as per ANSI B16.34 and acceptance criteria shall be as per ANSI B16.34 Annexure B. Two shots shall be taken for each area to be radiographed, as a minimum Please confrim Radipgraphy is applicable for Items Valves, Filter, PSV , Pressure Regulator & SSV. We understand thatif USM & Turbine Body is made of castign radiography is applicable and made of forging radiography is not applicable. Please confrim our understanding is correct. 100% Radiography is applicable for all the items made of casting. For forging/ formed material UT shall be conducted. 11 134 Data Sheet - Ball Valvee600# Data sheet doesn't show requirement of RT test Kindly confirm 100 % RT is required for pressure class > 600# Ball valves Confirmed. 12 143 Data Sheet - Check Valve600# Data sheet doesn't show requirement of RT test Kindly confirm 100 % RT is required for pressure class 600# check valves Confirmed.