Revised City Network Design Sample Clauses

Revised City Network Design. (a) For each City, during Contractor's performance of RF Engineering, Site Acquisition Services and Zoning for such City, Contractor shall collect additional data and perform additional analysis (including propagation testing from candidate Sites) to revise the Preliminary City Network Design in accordance with the Design Criteria. Based upon information obtained during the performance of RF Engineering, Site Acquisition Services and Zoning, the results of additional analysis and comments received from Owner, Contractor shall revise the Preliminary City Network Design as required to meet the Design Criteria. The revised Preliminary City Network Design shall be called the Revised City Network Design. (b) The Revised City Network Design will also identify those Sites to be constructed using a tower pursuant to the Master Tower Construction and Lease Agreement. (c) In developing the Revised City Network Design for each City, Contractor shall set up test transmitters at each Primary Candidate Site identified in the Preliminary City Network Design and measure the actual RF coverage from the Site along traffic routes agreed to by the Parties. For each Site, the deliverable shall be a Site/Cluster Test Report, including a signal strength plot showing the coverage provided by that Site. The coverage so measured shall be the basis for the design of further Sites within the relevant cluster. (d) For each City, Contractor shall provide Owner with a copy of a Revised City Network Design for Owner's review and acceptance. Owner will review the Revised City Network Design as submitted by Contractor. Owner will approve the Revised City Network Design as submitted by Contractor or direct Contractor to add Sites so as to satisfy the Design Criteria, revise the Defined Coverage Area (subject to the change order process set forth in Article 11 of the Terms and Conditions), revise any Exclusion Zones and/or delete Sites and declare further Exclusion Zones. Contractor shall revise the Revised City Network Design as directed by Owner and resubmit the same to Owner for review and written approval or direction by Owner in accordance with this Section. (e) In the event a Site requires isolation testing pursuant to Isolation Specifications attached hereto as Attachment 14, Contractor shall notify Owner through the Weekly Status Report and Contractor shall perform such isolation testing. (f) The foregoing may be accomplished on a Cluster-by-Cluster basis. In the event a Cluster desi...
AutoNDA by SimpleDocs

Related to Revised City Network Design

  • Network Interconnection Architecture Each Party will plan, design, construct and maintain the facilities within their respective systems as are necessary and proper for the provision of traffic covered by this Agreement. These facilities include but are not limited to, a sufficient number of trunks to the point of interconnection with the tandem company, and sufficient interoffice and interexchange facilities and trunks between its own central offices to adequately handle traffic between all central offices within the service areas at a P.01 grade of service or better. The provisioning and engineering of such services and facilities will comply with generally accepted industry methods and practices, and will observe the rules and regulations of the lawfully established tariffs applicable to the services provided.

  • System and Data Access Services a. System. Subject to the terms and conditions of this Addendum and solely for the purpose of providing access to Fund Data as set forth herein, State Street hereby agrees to provide the Fund, or certain third parties approved by State Street that serve as the Fund`s investment advisors, investment managers or fund accountants (the "Fund Accountants") or as the Fund`s independent auditors (the "Auditor"), with access to State Street`s Multicurrency HORIZONR Accounting System and the other information systems described in Attachment A (collectively, the "System") on a remote basis solely on the computer hardware, system software and telecommunication links described in Attachment B (the "Designated Configuration") or on any designated substitute or back-up equipment configuration consented to in writing by State Street, such consent not to be unreasonably withheld.

  • Interconnection Customer Authority Consistent with Good Utility Practice, this LGIA, and the CAISO Tariff, the Interconnection Customer may take actions or inactions with regard to the Large Generating Facility or the Interconnection Customer’s Interconnection Facilities during an Emergency Condition in order to (i) preserve public health and safety, (ii) preserve the reliability of the Large Generating Facility or the Interconnection Customer’s Interconnection Facilities,

  • Scope of Interconnection Service 1.3.1 The NYISO will provide Energy Resource Interconnection Service and Capacity Resource Interconnection Service to Interconnection Customer at the Point of Interconnection. 1.3.2 This Agreement does not constitute an agreement to purchase or deliver the Interconnection Customer’s power. The purchase or delivery of power and other services that the Interconnection Customer may require will be covered under separate agreements, if any, or applicable provisions of NYISO’s or Connecting Transmission Owner’s tariffs. The Interconnection Customer will be responsible for separately making all necessary arrangements (including scheduling) for delivery of electricity in accordance with the applicable provisions of the ISO OATT and Connecting Transmission Owner’s tariff. The execution of this Agreement does not constitute a request for, nor agreement to, provide Energy, any Ancillary Services or Installed Capacity under the NYISO Services Tariff or any Connecting Transmission Owner’s tariff. If Interconnection Customer wishes to supply or purchase Energy, Installed Capacity or Ancillary Services, then Interconnection Customer will make application to do so in accordance with the NYISO Services Tariff or Connecting Transmission Owner’s tariff.

  • Network Access TENANT may find it necessary to purchase a network interface card, wireless PC card or other hardware in order to connect to the internet service. LANDLORD is not responsible for the purchase of these items and LANDLORD cannot guarantee compatibility with any device TENANT may have. The computer and network card must have software installed that supports the Internet Protocol commonly referred to as TCP/IP. Any conflicts between the software compatibility of the network and the TENANT’S computer operating system or any other feature will be the responsibility of the TENANT to resolve. LANDLORD will not be responsible for software issues related to the user’s personal computer.

  • Verizon Operations Support Systems Verizon systems for pre- ordering, ordering, provisioning, maintenance and repair, and billing.

  • Network Services Local Access Services In lieu of any other rates and discounts, Customer will pay fixed monthly recurring local loop charges ranging from $1,200 to $2,000 for TDM-based DS-3 Network Services Local Access Services at 2 CLLI codes mutually agreed upon by Customer and Company.

  • Online Services Microsoft warrants that each Online Service will perform in accordance with the applicable SLA during Customer’s use. Customer’s remedies for breach of this warranty are described in the SLA.

  • NETWORK INTERCONNECTION METHODS 3.1 The Interconnection provided herein may not be used solely for the purpose of originating a Party’s own interexchange traffic.

  • NON-NETWORK PROVIDER is a provider that has not entered into a contract with us or any other Blue Cross and Blue Shield plan. For pediatric dental care services, non-network provider is a dentist that has not entered into a contract with us or does not participate in the Dental Coast to Coast Network. For pediatric vision hardware services, a non-network provider is a provider that has not entered into a contract with EyeMed, our vision care service manager.

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!