ROOF STRUCTURE Sample Clauses

ROOF STRUCTURE. The main Contractor is require to secure the services/ a resource that will be responsible for removing the coal stove, the chimney and close off the roof before insulation and other related activities can proceed. PMO will handle the collection and disposal of stoves.
AutoNDA by SimpleDocs
ROOF STRUCTURE. The Building Shell roof structure shall be constructed using metal columns, girders and joists, with wood framing members, and wood roof decking. Building structure clear height (lowest structural element) shall be 15 feet. The Building Shell roof structure shall be insulated with Code-required rigid insulation and shall remain exposed. Painting of roof structure and supporting elements, if required, is part of tenant improvement work. Metal stud furring and gypsum board for roof columns, if required, are part of tenant improvement work. EXTERIOR ENTRIES AND MAN DOORS: Building Shell doors are included as shown on drawings or exhibits. Doors in aluminum systems include single or double storefront doors with push-pull hardware, crash bar panic hardware and surface- mounted closers.
ROOF STRUCTURE. To be a combination of steel beam and open web steel joist and girder with steel deck. Roof structure shall slope to perimeter roof drains/scuppers at a minimum pitch of 1/4' per 1'-0". Provide built-up crickets around the building perimeter and at rooftop equipment to divert run-off toward roof drains.
ROOF STRUCTURE. Steel carrying girders with continuous connectors and shear straps as needed, 24' clear height.
ROOF STRUCTURE. The Owner or the Owner’s installing contractor shall provide and install additional framing, bracing or other means as required to support the panels, in accordance with local building department requirements.
ROOF STRUCTURE. The roof structure including all structural fixings and joints shall be designed to have a maintenance free design life and be adequately protected against corrosion or deterioration. The roof must support its self weight and all dead and imposed maximum loads safely and transfer them to the foundations as well as resisting movement caused by thermal and live load factors, as indicated in the relevant British Standards. Roof is to be fully insulated to current building regulations.
ROOF STRUCTURE. All objects mounted on the roof of any building such as air-conditioning units, exhaust fans, chillers, etc. must be screened from view from any street or adjoining building.
AutoNDA by SimpleDocs
ROOF STRUCTURE. The Tenant shall frame the roof structure of the front building adjacent to the open patio. No equipment installed above the suspended ceiling in this area may protrude above the roof line. The Landlord will reimburse the Tenant the reasonable costs of installing a drywall roof on top of this structure.
ROOF STRUCTURE. Metal deck with concrete, which is the same as the typical floors, but sloped for primary drainage. Thicker slabs as necessary for the mechanical areas of the penthouse.
ROOF STRUCTURE. A. Roof structure shall be comprised of Vulcraft type steel girder trusses, steel purlins with 1 3/4" nailers, 2x6 stiffeners, and the roof deck will be 15/32" O.S.