Sealing. (A) Meters must be sealed, and the seals maintained at all times, in accordance with Good Industry Practice.
Sealing. 12.5.1 The Facility Unit Metering Installation and the System Metering Installation shall each be sealed in accordance to their respective sealing policies in the presence of duly authorised representatives of both Parties immediately after the commissioning of the relevant meter.
Sealing o The shelter shall be sealed to resist dust and water infiltration. o All joints shall be sealed with a compressible resilient sealant. o There shall be no exposed roof-to-wall or wall-to-floor joints. o Exterior surfaces of walls and roof shall be sealed with two (2) coats of Thoroglaze H Sealer, or acceptable equivalent unless otherwise noted.
Sealing. Seal all longitudinal and transverse joints constructed as part of this work, as specified in Section 501.3(n). Seal all saw-cuts extending beyond the patch limits.
Sealing. Metering Equipment shall be as secure as is practicable in all the circumstances and for this purpose:-
Sealing. Sealing is defined as the application of an approved floor sealer prior to the application of the final floor finish according to industry standards and manufacturer recommendations. Application may be by either manual or mechanized methods. Standard: When properly sealed in compliance with the manufacturer’s recommendation the floor will present a uniform appearance with all evidence of splashing on baseboards and furniture/fixtures completely removed.
Sealing. All Submeters must be sealed at the moment of the Submeter commissioning test, and remain sealed for the duration of the participation of the Submetering Delivery Point to the Service. In case of need for an urgent intervention on the Submetering installation, the BSP will notify XXXX immediately. The Delivery Point will be suspended from Annex 1 until the problem is solved (by undergoing a new Submeter commissioning test if necessary). If sealing of the Submeter(s) is not technically possible, dispositions under Art. 6.5 and Art. 6.6 apply.
Sealing. Chloroprene sealant shall be applied for “all visual seam of floor and interior unweld seam”. * Butyl sealant shall be used for floor joint area, between door gasket and frame.
Sealing. The following parts must be sealed:
Sealing. (a) The Metering Installation and Check Metering Installation shall be sealed in the presence of duly authorised representatives of both Parties immediately after the commissioning of the Metering Installation and Check Metering Installation.
(b) Seals shall only be broken for the purposes of inspection, testing, maintenance or adjustment in the presence of duly authorised representatives of both Parties.