Switchgear Building Sample Clauses

Switchgear Building. All interconnections from the PCR and Switchgear buildings PLC Panels, etc. to the various field equipment and devices shall be routed via cable tray and conduit, as shown on the construction drawings. Cables are required to be “tray rated cables”. • Station Control Panel (SCP PLC) • Contractor shall install all interconnect wiring and communications between the Station Control Panel (SCP) and the following equipment, as noted on the construction drawings: • Station Control Remote I/O (SCP RIO 1), located in the yard (Communications). • Two (2) Generator Control Panels • Compressor Building Intrusion Switches • PCR Building Intrusion Switches • Office / Warehouse Building Intrusion Switches • SCP MCC RIO (Communications) • ESD MCC RIO (Communications) • Station ESD / Fire & Gas Panel (ESD PLC) • Contractor shall install all interconnect wiring and communications between the ESD Control Panel (ESD) and the following equipment, as noted on the construction drawings: • ESD / Fire & Gas Remote I/O (ESD RIO 1), located in Compressor Building (Communications). • PCR Building protection devices (smoke detectors, heat detectors, ESD push buttons, and EBD push buttons. • Office / Warehouse Building protection devices (smoke detectors, heat detectors, ESD push buttons, EBD push buttons, and horns. • Instrument / Utility Air Pressure Transmitter

Related to Switchgear Building

  • Capacity Building 1. Contractor will work in partnership with AOD to study the viability of billing under Drug Medi-Cal and 3rd party payer. 2. Contractor will document and track consumers who are CalWORKS eligible.

  • Building With respect to each parcel of Real Estate, all of the buildings, structures and improvements now or hereafter located thereon. Business Day. Any day on which banking institutions located in the same city and State as the Agent’s Head Office are located are open for the transaction of banking business and, in the case of LIBOR Rate Loans, which also is a LIBOR Business Day.

  • Building Systems “Building Systems” shall mean all structural elements and components, mechanical equipment, plumbing systems, electrical systems and life safety systems and fixtures incorporated in the Improvements, including, without limitation, HVAC, elevator, electrical, plumbing, utility, fire and life safety and swimming pool.

  • Electrical Provide drawings for the following systems: .1 Lighting including circuiting and luminaire identification and switching. Also provide illuminance computer printout for all indoor typical indoor spaces and parking lots. .2 Convenience outlets and circuiting, special outlets and circuiting, television outlets, and power systems and equipment. Provide riser diagrams for all electrical systems including master clock, intercom, fire alarm, ITV, computer networking/telephone. Also, provide for emergency and normal power distribution. Provide luminaire schedule. .3 Panel schedule may be in preliminary form but circuitry must be included. .4 Applicable installation details. .5 General legend and list of abbreviations. .6 Voltage drop computation for all main feeders. .7 Short circuit analysis .8 Provide 1/2" scale floor plan and wall elevations for all electrical rooms.

  • Lighting A system of fixtures providing or controlling the light sources used on or near the airport or within the airport buildings. The field lighting includes all luminous signals, markers, floodlights, and illuminating devices used on or near the airport or to aid in the operation of aircraft landing at, taking off from, or taxiing on the airport surface.