Telephone installation Sample Clauses

Telephone installation. If the Property has not previously been connected to a telephone line the Landlord, if requested by the Tenant, will pay for its installation. The Tenant will pay for its connection, or reconnection, in their name.
AutoNDA by SimpleDocs
Telephone installation and all costs therefor shall be the sole responsibility of Tenant, and Tenant shall make all necessary arrangements. Such telephone installations are subject to approval by Landlord and must be performed in strict compliance with all government codes.
Telephone installation. Tenant will furnish one complete set of plans with specifications to the Landlord for Landlord’s approval.
Telephone installation. The electrical contractor shall allow for the complete installation of all conduits, outlet boxes, G.P.O. Distribution Boards, etc., required for the installation of the telephone system as shown on the drawings. The size of all telephone conduits are indicated on the drawings and must be installed in the slab, walls or ceiling void. Galvanised steel draw-wires shall be installed in all conduits. End boxes must consist of a 50 mm x 100 mm x 100 mm outlet box fitted with suitable blank cover plates, flush mounted 350mm above the floor or behind the lower channel of the power skirting. Cover plates will be installed on all the outlet boxes. The outlet points on the power skirting must be fitted with grommets. The G.P.O. Distribution Boards must consist of a 150 mm x 600 mm x 600 mm metal box and hinged door with a 20 mm thick wooden backboard. The board must be flush mounted 1,37 m above the floor. The contractor will be responsible for the supply and installation of the 100mm ø sleeve pipe for the G.P.O. cable, which will be pointed out on site, but the principal contractor will erect the two manholes.
Telephone installation. Amount for initial telephone installation of: $125.00
Telephone installation and all costs therefor shall be the sole responsibility of Tenant, and Tenant shall make all necessary arrangements. Such telephone installations are subject to reasonable approval by Landlord and must be performed in strict compliance with all government codes, including a low voltage permit from the City of Stamford. At the expiration or earlier termination of the Lease, Tenant shall be responsible for the removal of all telecommunications and data wiring and any affiliated equipment in the Demised Premises and the Demised Premises (or New Demised Premises).
Telephone installation. In places where the electrical installation is under plaster, the telephone installation will also be made flush under galvanized or halogen-free pipe with plastic insulated or plastic sheathed special telephone cables with a diameter of at least 0.5 mm. Cables used in the installation will be manufactured in accordance with Turkish Standards. · Cables will be passed through galvanized or halogen-free pipes under plaster and will be fixed on special crochet and iron consoles or sheet channel weak current sections on the surface. In the main line installation made with insulated conductors, the pairs will be made into a regular string and will be passed through the pipe after bending. Such lines will not be passed through damp places in any way. · In places where high and weak current cables pass collectively, the necessary distance will be found between the cables belonging to the two types of installation. Cables with different voltage will never come into contact. · Internal surface-mounted telephone installation will be made with insulated and sheathed telephone cables. The tables shall be laid horizontally, through the cable paths specified in the project, vertically, through halogen-free or galvanized pipes. The cables used will be produced in accordance with Turkish Standards. · For the matters not mentioned in this specification, the provisions of XXX, XX, VDE or similar regulations and (TÜRK TELEKOM) specifications will be considered as the basis. · The additions of the low current installation will be collected in a box in proportion to the possibilities and the adjacent boxes will be in the same size. · Telephone connection boxes will be installed on surface of halogen free based material. · Krone-type connection modules will be used in connection boxes between the main lines coming from the exchange and the subscriber cables. (Cut type.) · Schemes containing connection schemes will be placed in the junction boxes. · Insulation resistance of the installation (for each subscriber) shall not be less than 6 megaohms.
AutoNDA by SimpleDocs
Telephone installation. The contractor shall supply all suitable cable sleeves (with draw wires), manholes and distribution boards with soft wooden back for the telephone installation in the positions as shown on the drawings and as specified in this specification. The successful tenderer shall have the telephone layout approved by TELKOM before installation commence.
Telephone installation. Telephone sleeves to be Bosal galvanized steel with draw wires. The main telephone DB shall be weatherproof and be 900x900mm with door and a soft wooden back plate, to be installed at the main telephone connection point. The successful tenderer shall have the telephone layout approved by TELKOM before installation commence. External communication connection boxes for buildings shall be acceptable by TELKOM, are weatherproof and be suitably sized.
Telephone installation. Notwithstanding Clause 10.02 of this Preliminaries Section, the Contractor shall allow for any or all services connections, whether temporary or permanent, to private or public mains, to be carried out in phases or outside normal working hours as may be required by the Employer. The Contractor shall attend as described in Clause 10.02 of this Preliminaries Section on The Telephone Companies installing telephone wiring and equipment and for assisting in the lifting and installation of cables within the curtilage of the Site. The Contractor shall attend as described in Clause 10.02 of this Preliminaries Section on installing power cables, equipment and installations and for assisting in the lifting and installation of cables within the curtilage of the Site.