Unbundled Sub-Loop Concentration (USLC). 2.8.6.1 Where facilities permit, Global Connection may concentrate its sub-loops onto multiple DS1s back to the BellSouth Central Office. 2.8.6.2 USLC, using the Lucent Series 5 equipment, will be offered in two system options. System A will allow up to 96 of Global Connection’s sub-loops to be concentrated onto two or more DS1s. System B will allow an additional 96 of Global Connection’s sub-loops to be concentrated onto two or more additional DS1s. One System A may be supplemented with one System B and they both must be physically located in a single Series 5 dual channel bank. A minimum of two DS1s is required for each system (i.e., System A requires two DS1s and System B would require an additional two DS1s or four in total). The DS1 level facility that connects the Remote Terminal site with the serving wire center is known as a Feeder Interface. All DS1 Feeder Interfaces will terminate to Global Connection’s demarcation point associated with Global Connection’s collocation space within the SWC that serves the remote terminal (RT). USLC service is offered with or without concentration and with or without a protection DS1. 2.8.6.3 Global Connection is required to deliver its sub-loops to its own cross-box, RT, or other similar device and deliver a single cable to the BellSouth RT. This cable shall be connected, by a BellSouth technician, to a cross-connect panel within the BellSouth RT/cross-box and shall allow Global Connection’s sub-loops to be placed on the USLC and transported to Global Connection’s collocation space at a DS1 level.
Appears in 3 contracts
Samples: Clec Agreement, Clec Agreement, Clec Agreement
Unbundled Sub-Loop Concentration (USLC). 2.8.6.1 Where facilities permit, Global Connection US LEC may concentrate its sub-loops onto multiple DS1s back to the BellSouth Central Office.
2.8.6.2 USLC, using the Lucent Series 5 equipment, will be offered in two system options. System A will allow up to 96 of Global ConnectionUS LEC’s sub-loops to be concentrated onto two or more DS1s. System B will allow an additional 96 of Global ConnectionUS LEC’s sub-loops to be concentrated onto two or more additional DS1s. One System A may be supplemented with one System B and they both must be physically located in a single Series 5 dual channel bank. A minimum of two DS1s is required for each system (i.e., System A requires two DS1s and System B would require an additional two DS1s or four in total). The DS1 level facility that connects the Remote Terminal site with the serving wire center is known as a Feeder Interface. All DS1 Feeder Interfaces will terminate to Global ConnectionUS LEC’s demarcation point associated with Global ConnectionUS LEC’s collocation space within the SWC that serves the remote terminal (RT). USLC service is offered with or without concentration and with or without a protection DS1.
2.8.6.3 Global Connection US LEC is required to deliver its sub-loops to its own cross-box, RT, or other similar device and deliver a single cable to the BellSouth RT. This cable shall be connected, connected by a BellSouth technician, technician to a cross-connect panel within the BellSouth RT/cross-box and shall allow Global ConnectionUS LEC’s sub-loops to be placed on the USLC and transported to Global ConnectionUS LEC’s collocation space at a DS1 level.
Appears in 1 contract
Samples: Interconnection Agreement