Common use of VEHICLE FEATURES Clause in Contracts

VEHICLE FEATURES. Seating - Standard floor plan is required with the RFP Price Proposal. Detailed floor plans are required during RFQ process. Exceptions to capacity required to meet other specifications must be noted. Base bus must accommodate12 ambulatory passengers in fixed seats and 2 front mounted wheelchair stations. Passenger Seats - Forward-facing mid-high back double seats secured to the vehicle floor and sidewall in accordance with FMVSS# 207. Seats must have a minimum of 17 inch cushion width and depth per person. All buses must have track type seat anchorages, to allow users to easily rearrange seating configurations. Aisle side armrests, molded plastic, are required to be installed Aisle side grab handles, molded plastic, are required to be installed Seat Belts - Must meet FMVSS #209 and #210. The driver's seat must be equipped with a retracting seat belt. All standard passenger seats must be equipped with under seat mounted retracting adult seat belts (USR or equivalent), except seats against rear of bus, which must have non-retracting seat belts. Seat materials - All seat materials must meet FMVSS #302. Level-3 vinyl upholstery is standard with color to be selected by purchaser from several available colors or patterns. Driver's seat must be a fully adjustable high-back bucket seat (USSC G2ELPQR or equivalent), with right side arm rest, adjustable tilt back and lumbar support with OEM standard pedestal and trim. The seat must be ergonomically designed to help reduce day to day driver fatigue and stress. The seat must covered with black transit cloth fabric. Priority seating signs and all other ADA required signage must be in place and installed per lift manufacturer and ADA standards. Ramp - ADA approved, must meet or exceed FMVSS #403 & #404 requirements and all State, Federal, ICC, and ADA requirements. The entry ramp must be designed to let wheelchair and ambulatory passengers enter the bus once the ramp is fully deployed. Steps are not allowed and all passengers must enter by way of passenger door. Entry ramp must be 62 inches minimum and provide a 1:6 angle when deployed to the ground. The ramp must be rated at 1000 lbs. Wheelchair Securement Devices must be automatic, self-tensioning with tensioning knob and self- locking and must comply with all ADA, ANSI/RESNA WC18 and ISO 10542 performance and installation requirements. Wheelchair securement must be flush mount aluminum “L” track of the highest quality. Wheelchair securement devices provided and the installation thereof, performance pursuant to this specification, must meet or surpass the minimum standards per ADA, ANSI/RESNA WC18 and ISO 10542 requirements, including all shoulder harness mounting hardware. Shoulder harness must have an adjustable height adjuster to compensate for variations in the size of the mobility device or passenger. At no time must the position of the wheelchair securement device or area, 30 inches wide per ADA, ANSI/RESNA WC18 and ISO 10542 specifications when used with a surrogate wheelchair per ADA, SAE and ISO, reduce clear aisle space to less than the dimension specified in this RFP. Wheelchair securement devices must be universal in application for ease of use or approved equal. Minimum wheelchair position must be 30” x 52” for all vehicles sold under this contract. Contractor must make available fixed floor pocket, Slide N Click, InQline Integrated Winch/Retractor System or approved equal based on desired configuration of the Authorized Purchaser at time of purchase. Floor track must be an Omni Floor Anchor System or equivalent and must be installed per the customer’s requirements and in accordance with manufacturer's recommendations. Length of floor track must be appropriate to the number of wheelchair stations ordered and the desired configuration. Floor track must be mounted with cadmium plated bolts for corrosion resistance. Wall Track must be surface mount “L” track 6351 grade aluminum or approved equal. Contractor must provide hands-on training of the tie- down system and provide manufacturer’s maintenance / training information at delivery. Heating Systems - Dual; install one (1) in front which will be the standard heater supplied in the chassis and one (1) rear heater. Rear heater must be rated at 65,000 BTU's minimum controlled at driver's console and must include a heater booster pump. Each heater must be fused and switched separately. Air Conditioning System - must have chassis OEM factory dash air conditioning plus a rear air conditioner unit to obtain 55,000 BTU minimum, with a minimum of three (3) blower speed settings, controlled at driver's console. Air Conditioning System must use Quick Click Hose system or equivalent. A spare tire and wheel matching the OEM tires must be included and shipped loose in the bus at delivery

Appears in 1 contract

Samples: State Price Agreement

AutoNDA by SimpleDocs

VEHICLE FEATURES. Seating - Standard floor plan is required with the RFP Price Proposal. Detailed floor plans are required during RFQ processwith vehicle orders. Exceptions to capacity required to meet other specifications must be noted. Base bus vehicle must accommodate12 accommodate 8 ambulatory passengers in fixed seats and 2 front rear mounted wheelchair stations. stations with full width track Passenger Seats - Forward-facing mid-high back double seats seats, or approved alternate, secured to the vehicle floor and sidewall in accordance with FMVSS# 207. Seats must have a minimum of 17 inch cushion width and depth per person. All buses must vehicles to have track type seat anchorages, to allow users to easily rearrange seating configurations. Aisle side armrests, molded plastic, are required to be installed Aisle side grab handles, molded plastic, are required to be installed Seat Belts - Must meet FMVSS #209 and #210. The driver's seat must be equipped with a retracting seat belt. All standard passenger seats must be equipped with either under seat mounted retracting adult seat belts (USR or equivalent), except ) for vehicles over 10,000 GVWR or 3-point seats belts for vehicles under 10,000 GVWR. Except seats against rear of busvehicle, which must have non-retracting seat beltsbelts in vehicles over 10,000 GVWR. Seat materials - All seat materials must meet FMVSS #302. Level-3 vinyl upholstery is standard with color to be selected by purchaser from several available colors or patterns. Driver's seat must be a fully adjustable high-back OEM bucket seat (USSC G2ELPQR or equivalent), with right side arm rest, adjustable tilt back and lumbar support with OEM standard pedestal and trim. The seat must be ergonomically designed to help reduce day to day driver fatigue and stress. The seat must be covered with black transit cloth or vinyl fabric. Priority seating signs and all other ADA required signage must be in place and installed per lift manufacturer and ADA standards. Ramp Lift - ADA approved, must meet or exceed FMVSS #403 & #404 requirements and all State, Federal, ICC, and ADA requirements. The entry ramp Fluid used must be designed to let wheelchair and ambulatory passengers enter the bus once the ramp is fully deployedHydraulic Fluid (Texaco #15, Exxon Univis HVI or Mobil Aero HFA or equivalent). Steps Minimum clear dimensions for platform are not allowed and all passengers must enter by way of passenger door. Entry ramp must be 62 inches minimum and provide a 1:6 angle when deployed to the ground34" wide X 51" length. The ramp standard location for the lift is on the curbside, behind the wheel xxxxx. The standard lift must be rated at 1000 for 800 lbs. minimum. Wheelchair Securement Devices must be automatic, self-tensioning with tensioning knob and self- self-locking and must comply with all ADA, ANSI/RESNA WC18 and ISO 10542 performance and installation requirements. Wheelchair securement must be flush mount aluminum “L” track of the highest quality. Wheelchair securement devices provided and the installation thereof, performance pursuant to this specification, must meet or surpass the minimum standards per ADA, ANSI/RESNA WC18 and ISO 10542 requirements, including all shoulder harness mounting hardware. Shoulder harness must have an adjustable height adjuster to compensate for variations in the size of the mobility device or passenger. At no time must the position of the wheelchair securement device or area, 30 inches wide per ADA, ANSI/RESNA WC18 and ISO 10542 specifications when used with a surrogate wheelchair per ADA, SAE and ISO, reduce clear aisle space to less than the dimension specified in this RFPallowed by ADA requirements. Wheelchair securement devices must be universal in application for ease of use or approved equal. Minimum wheelchair position must be 30” x 52” for all vehicles sold under this contract. Contractor must may make available fixed floor pocket, Slide N Click, InQline Integrated Winch/Retractor System or approved equal based on desired configuration of the Authorized Purchaser at time of purchase. Floor track must be an Omni Floor Anchor System or equivalent and must be installed per the customer’s requirements and in accordance with manufacturer's recommendations. Length of floor track must be appropriate to the number of wheelchair stations ordered and the desired configuration. Floor track must be mounted with cadmium plated bolts for corrosion resistance. Wall Track must be surface mount “L” track 6351 grade aluminum or approved equal. Contractor must Vendor shall provide hands-on training of the tie- tie-down system and provide manufacturer’s maintenance / training information at delivery. Heating Systems - Dual; install one (1) in front which will must be the standard heater supplied in the chassis and one (1) rear heater. Rear heater must be rated at 65,000 BTU's minimum controlled at driver's console and must include a heater booster pump. Each heater must be fused and switched separately. Air Conditioning System - must have chassis OEM factory dash air conditioning plus a rear air conditioner unit to obtain 55,000 BTU minimum, with a minimum of three (3) blower speed settings, controlled at driver's console. Air Conditioning System must use Quick Click Hose system or equivalent. A spare tire and wheel matching the OEM tires must be included and shipped loose in the bus at delivery.

Appears in 1 contract

Samples: State Price Agreement

VEHICLE FEATURES. Seating - Standard floor plan is required with the RFP Price Proposal. Detailed floor plans are required during RFQ processwith vehicle orders. Exceptions to capacity required to meet other specifications must be noted. Base bus vehicle must accommodate12 accommodate 24 ambulatory passengers in fixed seats and 2 front mounted wheelchair stationsstations with full length track. Passenger Seats - Forward-facing mid-high back double seats secured to the vehicle floor and sidewall in accordance with FMVSS# 207. Seats must have a minimum of 17 inch cushion width and depth per person. All buses must have track type seat anchorages, to allow users to easily rearrange seating configurations. Aisle side armrests, molded plastic, are required to be installed Aisle side grab handles, molded plastic, are required to be installed Seat Belts - Must meet FMVSS #209 and #210. The driver's seat must be equipped with a retracting seat belt. All standard passenger seats must be equipped with under seat mounted retracting adult seat belts (USR or equivalent), except seats against rear of busvehicle, which must have non-retracting seat belts. Seat materials - All seat materials must meet FMVSS #302. Level-3 vinyl upholstery is standard with color to be selected by purchaser from several available colors or patterns. Driver's seat must be a fully adjustable high-back bucket seat (USSC G2ELPQR or equivalent)seat, with right side arm rest, adjustable tilt back and lumbar support with OEM standard pedestal and trim. The seat must be ergonomically designed to help reduce day to day driver fatigue and stress. The seat must be covered with black transit cloth fabric. Air ride seat is required if available. Priority seating signs and all other ADA required signage must be in place and installed per lift manufacturer and ADA standards. Ramp Lift - ADA approved, must meet or exceed FMVSS #403 & #404 requirements and all State, Federal, ICC, and ADA requirements. The entry ramp Fluid used must be designed to let wheelchair and ambulatory passengers enter Hydraulic Fluid (Texaco #15, Exxon Univis HVI or Mobil Aero HFA or equivalent). Minimum clear dimensions for platform are 34" wide X 51" length. The standard location for the bus once lift is on the ramp is fully deployed. Steps are not allowed and all passengers must enter by way of passenger curbside, behind the entry door. Entry ramp must be 62 inches minimum and provide a 1:6 angle when deployed to the ground. The ramp standard lift must be rated at 1000 lbsfor 1000#. Wheelchair Securement Devices must be automatic, self-tensioning with tensioning knob and self- locking and must comply with all ADA, ANSI/RESNA WC18 and ISO 10542 performance and installation requirements. Wheelchair securement must be flush mount aluminum “L” track of the highest quality. Wheelchair securement devices provided installed and the installation thereof, performance pursuant to this specification, must meet or surpass the minimum standards per ADA, ANSI/RESNA WC18 and ISO 10542 requirements, including all shoulder harness mounting hardware. Shoulder harness must have an adjustable height adjuster to compensate for variations in the size of the mobility device or passenger. At no time must the position of the wheelchair securement device or area, 30 inches wide per ADA, ANSI/RESNA WC18 and ISO 10542 specifications when used with a surrogate wheelchair per ADA, SAE and ISO, reduce clear aisle space to less than the dimension specified in this RFPallowed by ADA requirements. Wheelchair securement devices must be universal in application for ease of use or approved equal. Minimum wheelchair position must be 30” x 52” for all vehicles sold under this contract. Contractor must may make available fixed floor pocket, Slide N Click, InQline Integrated Winch/Retractor System or approved equal based on desired configuration of the Authorized Purchaser at time of purchase. Floor track must be an Omni Floor Anchor System flange mount “L” track 6351 aluminum grade or equivalent approved equal and must be installed per lengthwise in relationship to the customer’s requirements and in accordance with manufacturer's recommendationsvehicle. Length of floor track must be appropriate to the number of wheelchair stations ordered and the desired configuration. Floor track must be mounted with the cadmium plated bolts for corrosion resistance. Wall Track must be surface mount “L” track 6351 grade aluminum or approved equal. Contractor must Vendor shall provide hands-on training of the tie- tie-down system and provide manufacturer’s maintenance / training information at delivery. Heating Systems - Dual; install one (1) in front which will be and rear heating system able to maintain a range of 65 to 70 degrees, measured about 12 inches off the standard heater supplied in the chassis and one (1) rear heater. Rear heater must be rated at 65,000 BTU's minimum controlled at driver's console and must include a heater booster pumpfloor with an ambient temperature of 0 degree. Each heater must be fused and switched separately. Air Conditioning System - must have chassis OEM factory dash Front and rear air conditioning plus system able to maintain a rear air conditioner unit range of 65 to obtain 55,000 BTU minimum70 degrees, measured about 12 inches off the floor with a minimum an ambient temperature of three (3) blower speed settings, controlled at driver's console90 degrees. Air Conditioning System must use Quick Click Hose system or equivalent. A spare tire and wheel matching the OEM tires must be included and shipped loose in the bus at deliveryInclude winter protection cover for skirt mounted condenser.

Appears in 1 contract

Samples: State Price Agreement

VEHICLE FEATURES. Seating - Standard floor plan is required with the RFP Price Proposal. Detailed floor plans are required during RFQ processwith vehicle orders. Exceptions to capacity required to meet other specifications must be noted. Base bus vehicle must accommodate12 accommodate 20 ambulatory passengers in fixed seats and 2 front mounted wheelchair stations. Passenger Seats - Forward-facing mid-high back double seats secured to the vehicle floor and sidewall in accordance with FMVSS# 207. Seats must have a minimum of 17 inch cushion width and depth per person. All buses must vehicles to have track type seat anchorages, to allow users to easily rearrange seating configurations. Aisle side armrests, molded plastic, are required to be installed Aisle side grab handles, molded plastic, are required to be installed Seat Belts - Must meet FMVSS #209 and #210. The driver's seat must be equipped with a retracting seat belt. All standard passenger seats must be equipped with under seat mounted retracting adult seat belts (USR or equivalent), except seats against rear of busvehicle, which must have non-retracting seat belts. Seat materials - All seat materials must meet FMVSS #302. Level-3 vinyl upholstery is standard with color to be selected by purchaser from several available colors or patterns. Driver's seat must be a fully adjustable high-back bucket seat (USSC G2ELPQR or equivalent), with right side arm rest, adjustable tilt back and lumbar support with OEM standard pedestal and trim. The seat must be ergonomically designed to help reduce day to day driver fatigue and stress. The seat must covered cover with black transit cloth fabric. An Air suspension seat is preferred and must be included as standard if available. Priority seating signs and all other ADA required signage must be in place and installed per lift manufacturer and ADA standards. Ramp - ADA approved, must meet or exceed FMVSS #403 & #404 requirements and all State, Federal, ICC, and ADA requirements. The entry ramp must be designed to let wheelchair and ambulatory passengers enter the bus vehicle once the ramp is fully deployed. Steps are not allowed and all passengers must enter by way of passenger door. Entry ramp must be 62 inches minimum and provide a 1:6 angle when deployed to the ground. The ramp must be rated at 1000 lbs. Wheelchair Securement Devices must be automatic, self-tensioning with tensioning knob and self- locking and must comply with all ADA, ANSI/RESNA WC18 and ISO 10542 performance and installation requirements. Wheelchair securement must be flush mount aluminum “L” track of the highest quality. Wheelchair securement devices provided and the installation thereof, performance pursuant to this specification, must meet or surpass the minimum standards per ADA, ANSI/RESNA WC18 and ISO 10542 requirements, including all shoulder harness mounting hardware. Shoulder harness must have an adjustable height adjuster to compensate for variations in the size of the mobility device or passenger. At no time must the position of the wheelchair securement device or area, 30 inches wide per ADA, ANSI/RESNA WC18 and ISO 10542 specifications when used with a surrogate wheelchair per ADA, SAE and ISO, reduce clear aisle space to less than the dimension specified in this RFPauthorized by ADA requirements. Wheelchair securement devices must be universal in application for ease of use or approved equal. Minimum wheelchair position must be 30” x 52” for all vehicles sold under this contract. Contractor must may make available fixed floor pocket, Slide N Click, InQline Integrated Winch/Retractor System or approved equal based on desired configuration of the Authorized Purchaser at time of purchase. Floor track must be an Omni Floor Anchor System flange mount “L” track 6351 aluminum grade or equivalent approved equal and must shall be installed per lengthwise in relationship to the customer’s requirements and in accordance with manufacturer's recommendationsvehicle. Length of floor track must be appropriate to the number of wheelchair stations ordered and the desired configuration. Floor track must be mounted with the cadmium plated bolts for corrosion resistance. Wall Track must be surface mount “L” track 6351 grade aluminum or approved equal. Contractor must shall provide hands-on training of the tie- tie-down system and provide include manufacturer’s maintenance / training information at delivery. Heating Systems - Dual; install one (1) in front which will be and rear heating system able to maintain a range of 65 to 70 degrees, measured about 12 inches off the standard heater supplied in the chassis and one (1) rear heater. Rear heater must be rated at 65,000 BTU's minimum controlled at driver's console and must include a heater booster pumpfloor with an ambient temperature of 0 degree. Each heater must be fused and switched separately. Air Conditioning System - must have chassis OEM factory dash Front and rear air conditioning plus system able to maintain a rear air conditioner unit range of 65 to obtain 55,000 BTU minimum70 degrees, measured about 12 inches off the floor with a minimum an ambient temperature of three (3) blower speed settings, controlled at driver's console90 degrees. Air Conditioning System must use Quick Click Hose system or equivalent. Include winter protection cover for skirt mounted condenser. A spare tire and wheel matching the OEM tires must be included and shipped loose in the bus vehicle at delivery

Appears in 1 contract

Samples: Vehicle Specifications

VEHICLE FEATURES. Seating - Standard floor plan is required with the RFP Price Proposalproposal. Detailed floor plans are required during RFQ processwith vehicle orders. Exceptions to capacity required to meet other specifications must be noted. Base bus vehicle must accommodate12 accommodate 24 ambulatory passengers in fixed seats and 2 front mounted wheelchair stations. Passenger Seats - Forward-facing mid-high back double seats secured to the vehicle floor and sidewall in accordance with FMVSS# 207. Seats must have a minimum of 17 inch cushion width and depth per person. All buses must vehicles to have track type seat anchorages, to allow users to easily rearrange seating configurations. Aisle side armrests, molded plastic, are required to be installed Aisle side grab handles, molded plastic, are required to be installed Seat Belts - Must meet FMVSS #209 and #210. The driver's seat must be equipped with a retracting seat belt. All standard passenger seats must be equipped with under seat mounted retracting adult seat belts (USR or equivalent), except seats against rear of busvehicle, which must have non-retracting seat belts. Seat materials - All seat materials must meet FMVSS #302. Level-3 vinyl upholstery is standard with color to be selected by purchaser from several available colors or patternsAuthorized Purchaser during the RFQ process. Driver's seat must be a fully adjustable high-back bucket seat (USSC G2ELPQR or equivalent), with right side arm rest, adjustable tilt back and lumbar support with OEM standard pedestal and trim. The seat must be ergonomically designed to help reduce day to day driver fatigue and stress. The seat must covered with black transit cloth fabric. Priority seating signs and all other ADA required signage must be in place and installed per lift manufacturer and ADA standards. Ramp - ADA approved, must meet or exceed FMVSS #403 & #404 requirements and all State, Federal, ICC, and ADA requirements. The entry ramp must be designed to let wheelchair and ambulatory passengers enter the bus vehicle once the ramp is fully deployed. Steps are not allowed and allowed, all passengers must enter by way of passenger door. Entry ramp must be 62 inches minimum and provide a 1:6 1:4 angle when deployed to the ground. The ramp must be rated at 1000 lbs. Wheelchair Securement Devices must be automatic, self-tensioning with tensioning knob and self- locking and must comply with all ADA, ANSI/RESNA WC18 and ISO 10542 performance and installation requirements. Wheelchair securement must be flush mount aluminum “L” track of the highest quality. Wheelchair securement devices provided installed and the installation thereof, performance pursuant to this specification, must meet or surpass the minimum standards per ADA, ANSI/RESNA WC18 and ISO 10542 requirements, including all shoulder harness mounting hardware. Shoulder harness must have an adjustable height adjuster to compensate for variations in the size of the mobility device or passenger. At no time must the position of the wheelchair securement device or area, 30 inches wide per ADA, ANSI/RESNA WC18 and ISO 10542 specifications when used with a surrogate wheelchair per ADA, SAE and ISO, reduce clear aisle space to less than the dimension specified in this RFPallowed by ADA requirements. Wheelchair securement devices must be universal in application for ease of use or approved equal. Minimum wheelchair position must be 30” x 52” for all vehicles sold under this contract. Contractor must may make available fixed floor pocket, Slide N Click, InQline Integrated Winch/Retractor System or approved equal based on desired configuration of the Authorized Purchaser at time of purchase. Floor track must be an Omni Floor Anchor System flange mount “L” track 6351 aluminum grade or equivalent approved equal and must be installed per lengthwise in relationship to the customer’s requirements and in accordance with manufacturer's recommendationsvehicle. Length of floor track must be appropriate to the number of wheelchair stations ordered and the desired configuration. Floor track must be mounted with the cadmium plated bolts for corrosion resistance. Wall Track must be surface mount “L” track 6351 grade aluminum or approved equal. Contractor must Vendor shall provide hands-on training of the tie- tie-down system and provide manufacturer’s maintenance / training information at delivery. Heating Systems - Dual; install one (1) in front which will be and rear heating system able to maintain a range of 65 to 70 degrees, measured about 12 inches off the standard heater supplied in the chassis and one (1) rear heater. Rear heater must be rated at 65,000 BTU's minimum controlled at driver's console and must include a heater booster pumpfloor with an ambient temperature of 0 degree. Each heater must be fused and switched separately. Air Conditioning System - must have chassis OEM factory dash Front and rear air conditioning plus system able to maintain a rear air conditioner unit range of 65 to obtain 55,000 BTU minimum70 degrees, measured about 12 inches off the floor with a minimum an ambient temperature of three (3) blower speed settings, controlled at driver's console90 degrees. Air Conditioning System must use Quick Click Hose system or equivalent. Include winter protection cover for skirt mounted condenser. A spare tire and wheel matching the OEM tires must be included and shipped loose in the bus vehicle at delivery

Appears in 1 contract

Samples: State Price Agreement

AutoNDA by SimpleDocs

VEHICLE FEATURES. Seating - Standard floor plan is required with the RFP Price Proposal. Detailed floor plans are required during RFQ processwith vehicle orders. Exceptions to capacity required to meet other specifications must be noted. Base bus vehicle must accommodate12 accommodate 10 ambulatory passengers in fixed seats and 2 1 front mounted wheelchair stationsstation. Passenger Seats - Forward-facing mid-high back double seats seats, or DAS/Agency approved alternate, secured to the vehicle floor and sidewall frame in accordance with FMVSS# 207. Seats must have a minimum of 17 inch cushion width and depth per person. All buses Contractor must have track type seat anchorages, to allow users to easily rearrange seating configurations. install Aisle side armrests, molded plastic, are required to be installed . Aisle side grab handles, molded plastic, are required to be installed Seat Belts - Must meet FMVSS #209 and #210. The driver's seat must be equipped with a retracting seat belt. All standard passenger seats must be equipped with either under seat mounted retracting adult seat belts (USR or equivalent), except ) for vehicles over 10,000 GVWR or 3-point seats belts for vehicles under 10,000 GVWR. Except seats against rear of busvehicle, which must have non-retracting seat beltsbelts in vehicles over 10,000 GVWR. Seat materials - All seat materials must meet FMVSS #302. Level-3 vinyl upholstery is standard with color to be selected by purchaser from several available colors or patterns. Driver's seat must be a fully adjustable high-back OEM bucket seat (USSC G2ELPQR or equivalent), with right side arm rest, adjustable tilt back and lumbar support with OEM standard pedestal and trim. The seat must be ergonomically designed to help reduce day to day driver fatigue and stress. The seat must covered with black or grey transit cloth fabric. Priority seating signs and all other ADA required signage must be in place and installed per lift manufacturer and ADA standards. Ramp - ADA approved, must meet or exceed FMVSS #403 & #404 requirements and all State, Federal, ICC, and ADA requirements. The entry ramp must be designed to let wheelchair and ambulatory passengers enter the bus vehicle once the ramp is fully deployed. Steps are not allowed and all passengers must enter by way of passenger door. Entry ramp must be 62 inches minimum and provide a 1:6 angle when deployed to the ground. The ramp must be rated at 1000 800 lbs. minimum. Wheelchair Securement Devices must be automatic, self-tensioning with tensioning knob and self- locking and must comply with all ADA, ANSI/RESNA WC18 and ISO 10542 performance and installation requirements. Wheelchair securement must be flush mount aluminum “L” track of the highest quality. Wheelchair securement devices provided and the installation thereof, performance pursuant to this specification, must meet or surpass the minimum standards per ADA, ANSI/RESNA WC18 and ISO 10542 requirements, including all shoulder harness mounting hardware. Shoulder harness must have an adjustable height adjuster to compensate for variations in the size of the mobility device or passenger. At no time must the position of the wheelchair securement device or area, 30 inches wide per ADA, ANSI/RESNA WC18 and ISO 10542 specifications when used with a surrogate wheelchair per ADA, SAE and ISO, reduce clear aisle space to less than the dimension specified in this RFPallowed by ADA requirements. Wheelchair securement devices must be universal in application for ease of use or approved equal. Minimum wheelchair position must be 30” x 52” for all vehicles sold under this contractvehicles. Contractor The vendor must make available “L” Track, fixed floor pocket, Slide N Click, InQline In Qline Integrated Winch/Retractor System or approved equal based on desired configuration of the Authorized Purchaser at time of purchase. Floor track must be an Omni Floor Anchor System or equivalent and must be installed per the customer’s requirements and in accordance with manufacturer's recommendations. Length of floor track must be appropriate to the number of wheelchair stations ordered and the desired configuration. Floor track must be mounted with cadmium plated bolts for corrosion resistance. Wall Track must be surface mount “L” track 6351 grade aluminum or approved equal. Contractor must Vendor shall provide hands-on training of the tie- tie-down system and provide manufacturer’s maintenance / training information at delivery. Heating Systems - Dual; install one (1) in front which will must be the standard heater supplied in the chassis and one (1) rear heater. Rear heater must be rated at 65,000 BTU's minimum controlled at driver's console and must include a heater booster pump. Each heater must be fused and switched separately. Air Conditioning System - must have chassis OEM factory dash air conditioning plus a rear air conditioner unit to obtain 55,000 BTU minimum, with a minimum of three (3) blower speed settings, controlled at driver's console. Air Conditioning System must use Quick Click Hose system or equivalent. A spare tire and wheel matching the OEM tires must be included and shipped loose in the bus at delivery.

Appears in 1 contract

Samples: State Price Agreement

VEHICLE FEATURES. Seating - Standard floor plan is required with the RFP Price Cost Proposal. Detailed floor plans are required during RFQ processwith vehicle orders. Exceptions to capacity required to meet other specifications must be noted. Base bus vehicle must accommodate12 accommodate 20 ambulatory passengers in fixed seats and 2 front mounted wheelchair stationsstations with full length track. Passenger Seats - Forward-facing mid-high back double seats secured to the vehicle floor and sidewall in accordance with FMVSS# 207. Seats must have a minimum of 17 inch cushion width and depth per person. All buses must vehicles to have track type seat anchorages, to allow users to easily rearrange seating configurations. Perimeter seating allowed on purpose built transit vehicles. Aisle side armrests, molded plastic, are required to be installed Aisle side grab handles, molded plastic, are required to be installed Seat Belts - Must meet FMVSS #209 and #210. The driver's seat must be equipped with a retracting seat belt. All standard passenger seats must be equipped with under seat mounted retracting adult seat belts (USR or equivalent), except seats against rear of busvehicle, which must have non-retracting seat belts. Seat materials - All seat materials must meet FMVSS #302. Level-3 vinyl upholstery is standard with color to be selected by purchaser from several available colors or patterns. Driver's seat must be a fully adjustable high-back bucket seat (USSC G2ELPQR or equivalent)seat, with right side arm rest, adjustable tilt back and lumbar support with OEM standard pedestal and trim. The seat must be ergonomically designed to help reduce day to day driver fatigue and stress. The seat must covered with black transit cloth fabric. Air ride seat is required if available. Priority seating signs and all other ADA required signage must be in place and installed per lift manufacturer and ADA standards. Ramp Lift - ADA approved, must meet or exceed FMVSS #403 & #404 requirements and all State, Federal, ICC, and ADA requirements. The entry ramp Fluid used must be designed to let wheelchair and ambulatory passengers enter Hydraulic Fluid (Texaco #15, Exxon Univis HVI or Mobil Aero HFA or equivalent). Minimum clear dimensions for platform are 34" wide X 51" length. The standard location for the bus once lift is on the ramp is fully deployed. Steps are not allowed and all passengers must enter by way of passenger curbside, behind the entry door. Entry ramp must be 62 inches minimum and provide a 1:6 angle when deployed to the ground. The ramp standard lift for base vehicle must be rated at 1000 lbsfor 1000#. Wheelchair Securement Devices must be automatic, self-tensioning with tensioning knob and self- locking and must comply with all ADA, ANSI/RESNA WC18 and ISO 10542 performance and installation requirements. Wheelchair securement must be flush mount aluminum “L” track of the highest quality. Wheelchair securement devices provided installed and the installation thereof, performance pursuant to this specification, must meet or surpass the minimum standards per ADA, ANSI/RESNA WC18 and ISO 10542 requirements, including all shoulder harness mounting hardware. Shoulder harness must have an adjustable height adjuster to compensate for variations in the size of the mobility device or passenger. At no time must the position of the wheelchair securement device or area, 30 inches wide per ADA, ANSI/RESNA WC18 and ISO 10542 specifications when used with a surrogate wheelchair per ADA, SAE and ISO, reduce clear aisle space to less than the dimension specified in this RFPallowed by ADA requirements. Wheelchair securement devices must be universal in application for ease of use or approved equal. Minimum wheelchair position must be 30” x 52” for all vehicles sold under this contract. Contractor must may make available fixed floor pocket, Slide N Click, InQline Integrated Winch/Retractor System or approved equal based on desired configuration of the Authorized Purchaser at time of purchase. Floor track must be an Omni Floor Anchor System flange mount “L” track 6351 aluminum grade or equivalent approved equal and must be installed per lengthwise in relationship to the customer’s requirements and in accordance with manufacturer's recommendationsvehicle. Length of floor track must be appropriate to the number of wheelchair stations ordered and the desired configuration. Floor track must be mounted with the cadmium plated bolts for corrosion resistance. Wall Track must be surface mount “L” track 6351 grade aluminum or approved equal. Contractor must shall provide hands-on training of the tie- tie-down system and provide include manufacturer’s maintenance / training information at delivery. Heating Systems - Dual; install one (1) in front which will be and rear heating system able to maintain a range of 65 to 70 degrees, measured about 12 inches off the standard heater supplied in the chassis and one (1) rear heater. Rear heater must be rated at 65,000 BTU's minimum controlled at driver's console and must include a heater booster pumpfloor with an ambient temperature of 0 degree. Each heater must be fused and switched separately. Air Conditioning System - must have chassis OEM factory dash Front and rear air conditioning plus system able to maintain a rear air conditioner unit range of 65 to obtain 55,000 BTU minimum70 degrees, measured about 12 inches off the floor with a minimum an ambient temperature of three (3) blower speed settings, controlled at driver's console90 degrees. Air Conditioning System must use Quick Click Hose system or equivalent. Include winter protection cover for skirt mounted condenser. A spare tire and wheel matching the OEM tires must be included and shipped loose in the bus vehicle at delivery

Appears in 1 contract

Samples: Vehicle Specifications

VEHICLE FEATURES. Seating - Standard floor plan is required with the RFP Price Proposal. Detailed floor plans are required during RFQ processprocess for vehicle orders. Exceptions to capacity required to meet other specifications must be noted. Base bus vehicle must accommodate12 ambulatory passengers in fixed seats and 2 front mounted wheelchair stationsstations with full length track and be no less than 24’ in overall length. Passenger Seats - Forward-facing mid-high back double seats secured to the vehicle floor and sidewall in accordance with FMVSS# 207. Seats must have a minimum of 17 inch cushion width and depth per person. All buses vehicles must have track type seat anchorages, to allow users to easily rearrange seating configurations. Aisle side armrests, molded plastic, are required to be installed Aisle side grab handles, molded plastic, are required to be installed Seat Belts - Must meet FMVSS #209 and #210. The driver's seat must be equipped with a retracting seat belt. All standard passenger seats must be equipped with under seat mounted retracting adult seat belts (USR or equivalent), except seats against rear of busvehicle, which must have non-retracting seat belts. Seat materials - All seat materials must meet FMVSS #302. Level-3 vinyl upholstery is standard with color to be selected by purchaser from several available colors or patterns. Driver's seat must be a fully adjustable high-back bucket seat (USSC G2ELPQR or equivalent), with right side arm rest, adjustable tilt back and lumbar support with OEM standard pedestal and trim. The seat must be ergonomically designed to help reduce day to day driver fatigue and stress. The seat must be covered with black or gray transit cloth fabric. Priority seating signs and all other ADA required signage must be in place and installed per lift manufacturer and ADA standards. Ramp Lift - ADA approved, must meet or exceed FMVSS #403 & #404 requirements and all State, Federal, ICC, and ADA requirements. The entry ramp Fluid used must be designed to let wheelchair and ambulatory passengers enter Hydraulic Fluid (Texaco #15, Exxon Univis HVI or Mobil Aero HFA or equivalent). Minimum clear dimensions for platform are 34" wide X 51" length. The standard location for the bus once lift is on the ramp is fully deployed. Steps are not allowed and all passengers must enter by way of passenger curbside, behind the entry door. Entry ramp must be 62 inches minimum and provide a 1:6 angle when deployed to the ground. The ramp standard lift must be rated at 1000 lbsfor 1000#. A credit must be given to Agencies that request an 800# lift. Wheelchair Securement Devices must be automatic, self-tensioning with tensioning knob and self- locking and must comply with all ADA, ANSI/RESNA WC18 and ISO 10542 performance and installation requirements. Wheelchair securement must be flush mount aluminum “L” track of the highest quality. Wheelchair securement devices provided and the installation thereof, performance pursuant to this specification, must meet or surpass the minimum standards per ADA, ANSI/RESNA WC18 and ISO 10542 requirements, including all shoulder harness mounting hardware. Shoulder harness must have an adjustable height adjuster to compensate for variations in the size of the mobility device or passenger. At no time must the position of the wheelchair securement device or area, 30 inches wide per ADA, ANSI/RESNA WC18 and ISO 10542 specifications when used with a surrogate wheelchair per ADA, SAE and ISO, reduce clear aisle space to less than the dimension specified in this RFP. Wheelchair securement devices must be universal in application for ease of use or approved equal. Minimum wheelchair position must be 30” x 52” for all vehicles sold under this contract. The Contractor must make available fixed floor pocket, Slide N Click, InQline Integrated Winch/Retractor System or approved equal based on desired configuration of the Authorized Purchaser at time of purchase. Floor track must be an Omni Floor Anchor System or equivalent and must be installed per the customer’s requirements and in accordance with manufacturer's recommendations. Length of floor track must be appropriate to the number of wheelchair stations ordered and the desired configuration. Floor track must be mounted with cadmium plated bolts for corrosion resistance. Wall Track must be surface mount “L” track 6351 grade aluminum or approved equal. Contractor must provide hands-on training of the tie- tie-down system and provide manufacturer’s maintenance / training information at delivery. Heating Systems - Dual; install one (1) in front which will be the standard heater supplied in the chassis and one (1) rear heater. Rear heater must be rated at 65,000 BTU's minimum controlled at driver's console and must include a heater booster pump. Each heater must be fused and switched separately. Air Conditioning System - must have chassis OEM factory dash air conditioning plus a rear air conditioner unit to obtain 55,000 BTU minimum, with a minimum of three (3) blower speed settings, controlled at driver's console. Air Conditioning System must use Quick Click Hose system or equivalent. A spare tire and wheel matching the OEM tires must be included and shipped loose in the bus vehicle at delivery

Appears in 1 contract

Samples: State Price Agreement

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!