Common use of VISCOSITY Clause in Contracts

VISCOSITY. The specified maximum Viscosity for Fuel Oils provided under this contract shall be as specified in Table I and Table II, elsewhere within this specification. Delivered product having a viscosity greater than that specified for the respective product shall be adjusted in price as specified elsewhere herein for NON-COMPLYING PRODUCT. Delivered product having a viscosity greater than the specified shall be removed from the purchasing agency’s tank and replaced with product conforming to specifications, at purchasing agency’s discretion based on excessive filter maintenance and/or poor burner performance. The Viscosity shall be determined using - ASTM Test Method D445-12 (IP #71-84), latest revision thereof, or approved equivalent method, and ASTM D2161-10, conversion of Kinematic Viscosity to Saybolt Universal Seconds (SUS) or to Saybolt Furol Seconds (SFS), latest revision thereof, or approved equivalent method, - relative to the individual characteristics of the product being tested. After receiving a written request by purchasing agency, the contractor’s delivery ticket will state the fuel’s viscosity (cSt, SUS, SFS).

Appears in 27 contracts

Samples: Agreement, Agreement, Agreement

AutoNDA by SimpleDocs

VISCOSITY. The specified maximum Viscosity for Fuel Oils provided under this contract shall be as specified in Table I and Table II, elsewhere within this specification. Delivered product having a viscosity greater than that specified for the respective product shall be adjusted in price as specified elsewhere herein for NON-COMPLYING PRODUCT. Delivered product having a viscosity greater than the specified shall be removed from the purchasing agency’s tank and replaced with product conforming to specifications, at purchasing agency’s discretion based on excessive filter maintenance and/or poor burner performance. The Viscosity shall be determined using - ASTM Test Method D445-12 (IP #71-84), latest revision thereof, or approved equivalent method, and ASTM D2161-10, conversion of Kinematic Viscosity to Saybolt Universal Seconds (SUS) or to Saybolt Furol Seconds (SFS), latest revision thereof, or approved equivalent method, - relative to the individual characteristics of the product being tested. After receiving a written request by purchasing agency, the contractor’s delivery ticket will state the fuel’s viscosity (cSt, SUS, SFS).

Appears in 2 contracts

Samples: Agreement, Agreement

AutoNDA by SimpleDocs

VISCOSITY. The specified maximum Viscosity for Fuel Oils provided under this contract shall be as specified in Table I and Table II, elsewhere within this specification. Delivered product having a viscosity greater than that specified for the respective product shall be adjusted in price as specified elsewhere herein for NON-COMPLYING PRODUCT. Delivered product having a viscosity greater than the specified shall be removed from the purchasing agency’s tank and replaced with product conforming to specifications, at purchasing agency’s discretion based on excessive filter maintenance and/or poor burner performance. The Viscosity shall be determined using - ASTM Test Method D445-12 D445 (IP #71-84), ) or latest revision thereof, or approved equivalent method, and ASTM D2161-10, conversion of Kinematic Viscosity to Saybolt Universal Seconds (SUS) or to Saybolt Furol Seconds (SFS), ) or latest revision revision(s) thereof, or approved equivalent method, - relative to the individual characteristics of the product being tested. After receiving a written request by purchasing agency, the contractor’s delivery ticket will state the fuel’s viscosity (cSt, SUS, SFS).

Appears in 1 contract

Samples: Agreement

Time is Money Join Law Insider Premium to draft better contracts faster.