Wall Insulation Sample Clauses

Wall Insulation. Batt thermal Insulation for exterior walls of the building shall be mineral or glass fiber conforming to federal specifications HH-I-S21 and ASTM C665. Flame spread shall not exceed 25, ASTM E84. ▇▇▇▇▇ shall be rated at R-19 or better. Sound attenuation batt insulation for interior walls shall be 3” thick, USG Thermafiber conforming to ASTM C655, and federal specification HH-1-521E, type I or II. Please see note in 7.1 above regarding sound transmission coefficient.
Wall Insulation. Batt insulation for exterior walls of the building shall be mineral or glass fiber conforming to Federal specifications HH-I-S21 and ASTM C665. Flame spread shall not exceed 25, ASTM E84. ▇▇▇▇▇ shall be rated at R-11 or better. Provide a sound transmission coefficient of not less than 45 in all floor-to-ceiling interior walls and horizontal acoustic grid ceilings that enclose private offices, conference rooms, break rooms, libraries, and rest rooms - to accomplish this, said walls may have to extend a minimum 12" above the drop ceiling. STOP POINT: The Lessee is to be given at least a 48 hour advance notification to conduct an on-site inspection after insulation is installed and before the wall finish process is started. An inspection will be made by the Lessee within 2 business days of receipt of notification. Sound attenuation batt insulation for interior walls shall be 3” thick, United State Gypsum Thermafiber conforming to ASTM C655, and Federal Specification HH-1-521E, Type I or II or approved equal.
Wall Insulation. Batt Insulation for exterior walls of the building shall be mineral or glass fiber conforming to Federal specifications HH-I-S21 and ASTM C665. Flame spread shall not exceed 25, ASTM E84. ▇▇▇▇▇ shall be rated at R-11 or better.
Wall Insulation. Wall insulation may only be installed under the following conditions: ◼ Wall venting must comply with the local building department codes or the Uniform Building Code requirements. ◼Ceiling must be structurally sound to support the weight of the insulation and crew. Wall Insulation? ◼ No hazardous electrical wiring is present. ◼ Work does not disturb asbestos or other hazardous material. ◼ Where local building departments do not allow insulation over knob-and-tube wiring, the live knob-and-tube wiring must be certified safe by an electrical contractor licensed in the state of CA. Some local jurisdictions require dead knob and t& Tube wiring to be removed before insulating so that it cannot be re- energized. ◼ The installed insulation achieves a minimum of R-13.

Related to Wall Insulation

  • Insulation In exterior walls? Yes No Unknown In ceiling/attic? Yes No Unknown In any other areas? Yes No Where? Comments:

  • GLASS Coverage is provided for all loss or damages to exterior glass, lettering, ornamentation and burglar foils thereon, caused by accidental breakage of such glass. The Insurer shall not be liable under this Additional Agreement for coverage for: a) loss or damage directly or indirectly from fire whether in the “premises” described in the “Declaration Page” or elsewhere; b) loss or damage caused directly or indirectly by the perils excluded in Perils Excluded section 6.B of the Commercial Property Broad Form (CMF-0005-1218); c) the cost of removing or replacing any fixtures or other obstructions to the replacement of the glass.

  • Asbestos Any material that contains more than one percent asbestos and is friable or is releasing asbestos fibers into the air above current action levels established by the United States Occupational Safety and Health Administration.

  • Explosives Explosives or other highly flammable substances shall not be stored or used on Railroad's property without the prior written approval of Railroad.

  • Rubric The rubrics are a scoring tool used for the Educator’s self-assessment, the formative assessment, the formative evaluation and the summative evaluation. The districts may use either the rubrics provided by ESE or comparably rigorous and comprehensive rubrics developed or adopted by the district and reviewed by ESE.