Water Supply, Service Agreement, and Pre-Treatment System. Owner shall supply on-site process xxxxx or other water source that is capable of providing a quantity of raw water satisfying the needs of the Plant. Owner should consider providing a redundant water supply source. Owner will supply one process fresh water supply line terminating within five (5) feet of the point of entry designated by Design-Builder, and one potable supply line terminating within five (5) feet of the process building and to the administration building at a point of entry designated by administration building contractor. Owner shall pay for a water pre-treatment system to be designed and constructed by Design-Builder and to be integrated into the Plant. The pre-treatment system will be designed to provide the Plant with the quantity and quality of raw and treated water needed to supply the Plant’s process needs. Owner shall maintain and use the water pre-treatment system, including the use of all chemicals specified for the operation of such water pre-treatment system, for the entirety of the warranty period set forth in the Design-Build agreement as such may be extended in accordance therewith. Owner’s failure to maintain and to properly use such water pre-treatment system for the warranty period set forth in the Design-Build Agreement shall void any and all warranties affected by such failure. The pre-treatment system shall be supplied by a vendor selected and approved by Design-Builder and shall meet specifications and designs approved by Design-Builder. The water pre-treatment system design will be required to meet the discharge requirements under the Plant’s wastewater discharge permit. Owner shall execute side-letter agreements with Design-Builder as necessary for the design and construction of such water pre-treatment system. Design-Builder shall recover costs for the design and construction of such system from the Owner at Design-Builder’s standard time plus material rates during the relevant time period and at the relevant locale.
Appears in 2 contracts
Samples: Lump Sum Design Build Agreement (Advanced BioEnergy, LLC), Lump Sum Design Build Agreement (Advanced BioEnergy, LLC)
Water Supply, Service Agreement, and Pre-Treatment System. Owner shall supply on-site process xxxxx wxxxx or other water source that is capable of providing a quantity of raw water satisfying the needs of the Plant. Owner should consider providing a redundant water supply source. Owner will supply one process fresh water supply line terminating within five (5) feet of the point of entry designated by Design-Builder, and one potable supply line terminating within five (5) feet of the process building and to the administration building at a point of entry designated by administration building contractor. Owner shall pay for a water pre-treatment system to be designed and constructed by Design-Builder and to be integrated into the Plant. The pre-treatment system will be designed to provide the Plant with the quantity and quality of raw and treated water needed to supply the Plant’s process needs. Owner shall maintain and use the water pre-treatment system, including the use of all chemicals specified for the operation of such water pre-treatment system, for the entirety of the warranty period set forth in the Design-Build agreement as such may be extended in accordance therewith. Owner’s failure to maintain and to properly use such water pre-treatment system for the warranty period set forth in the Design-Build Agreement shall void any and all warranties affected by such failure. The pre-treatment system shall be supplied by a vendor selected and approved by Design-Builder and shall meet specifications and designs approved by Design-Builder. The water pre-treatment system design will be required to meet the discharge requirements under the Plant’s wastewater discharge permit. Owner shall execute side-letter agreements with Design-Builder as necessary for the design and construction of such water pre-treatment system. Design-Builder shall recover costs for the design and construction of such system from the Owner at Design-Builder’s standard time plus material rates during the relevant time period and at the relevant locale.
Appears in 2 contracts
Samples: Lump Sum Design Build Agreement (Cardinal Ethanol LLC), Lump Sum Design Build Agreement (First United Ethanol LLC)
Water Supply, Service Agreement, and Pre-Treatment System. Owner shall supply on-site process xxxxx wxxxx or other water source that is capable of providing a the incremental quantity of raw water, which includes process water, R.O. feed water, cooling tower make-up water satisfying the needs and boiler feed water, of a quality which will allow discharges to comply with NPDES limits and stable operation of the Plantplant. Owner should consider providing a redundant water supply source. Owner will supply one process fresh water supply line terminating within five (5) feet of the point of entry designated by Design-Builder, and one potable supply line terminating within five (5) feet of the process building and to the administration building at a point of entry designated by administration building contractor. Owner shall pay for a water pre-treatment system to be designed and constructed by Design-Builder and to be integrated into the Expansion Plant. Owner shall provide an updated water sample of current process water for analysis to aid in design of the water pre-treatment system. The pre-treatment system will be designed to provide the Expansion Plant with the quantity and quality of raw and treated water needed to supply the Expansion Plant’s process needs. Owner shall maintain and use the water pre-treatment system, including the use of all chemicals specified for the operation of such water pre-treatment system, for the entirety of the warranty period set forth in the Design-Build agreement as such may be extended in accordance therewith. Owner’s failure to maintain and to properly use such water pre-treatment system for the warranty period set forth in the Design-Build Agreement shall void any and all warranties affected by such failure. The pre-treatment system shall be supplied by a vendor selected and approved by Design-Builder and shall meet specifications and designs approved by Design-Builder. The water pre-treatment system design will be also consider and recommend to Owner equipment required to meet the discharge requirements under the Expansion Plant’s wastewater discharge permit. Owner shall is to execute side-letter agreements with Design-Builder as necessary for the design and construction of such water pre-treatment system. Design-Builder shall recover costs for the design and construction of such system from the Owner at Design-Builder’s standard time plus material rates during the relevant time period and at the relevant locale. A side-letter agreement between Owner and Design-Builder shall be executed by Owner and Design-Builder to compensate Design-Builder, at Design-Builder’s standard time plus materials rates during the relevant time period and at the relevant locale, for any costs and expenses related to such water pre-treatment system.
Appears in 1 contract
Samples: Lump Sum Design Build Expansion Agreement (US BioEnergy CORP)
Water Supply, Service Agreement, and Pre-Treatment System. Owner shall supply on-site process xxxxx or other water source that is capable of providing a the incremental quantity of raw water, which includes process water, R.O. feed water, cooling tower make-up water satisfying the needs and boiler feed water, of a quality which will allow discharges to comply with NPDES limits and stable operation of the Plantplant. Owner should consider providing a redundant water supply source. Owner will supply one process fresh water supply line terminating within five (5) feet of the point of entry designated by Design-Builder, and one potable supply line terminating within five (5) feet of the process building and to the administration building at a point of entry designated by administration building contractor. Owner shall pay for a water pre-treatment system to be designed and constructed by Design-Builder and to be integrated into the Expansion Plant. Owner shall provide an updated water sample of current process water for analysis to aid in design of the water pre-treatment system. The pre-treatment system will be designed to provide the Expansion Plant with the quantity and quality of raw and treated water needed to supply the Expansion Plant’s process needs. Owner shall maintain and use the water pre-treatment system, including the use of all chemicals specified for the operation of such water pre-treatment system, for the entirety of the warranty period set forth in the Design-Build agreement as such may be extended in accordance therewith. Owner’s failure to maintain and to properly use such water pre-treatment system for the warranty period set forth in the Design-Build Agreement shall void any and all warranties affected by such failure. The pre-treatment system shall be supplied by a vendor selected and approved by Design-Builder and shall meet specifications and designs approved by Design-Builder. The water pre-treatment system design will be also consider and recommend to Owner equipment required to meet the discharge requirements under the Expansion Plant’s wastewater discharge permit. Owner shall is to execute side-letter agreements with Design-Builder as necessary for the design and construction of such water pre-treatment system. Design-Builder shall recover costs for the design and construction of such system from the Owner at Design-Builder’s standard time plus material rates during the relevant time period and at the relevant locale. A side-letter agreement between Owner and Design-Builder shall be executed by Owner and Design-Builder to compensate Design-Builder, at Design-Builder’s standard time plus materials rates during the relevant time period and at the relevant locale, for any costs and expenses related to such water pre-treatment system.
Appears in 1 contract
Samples: Lump Sum Design Build Expansion Agreement (Golden Grain Energy)
Water Supply, Service Agreement, and Pre-Treatment System. Owner shall supply on-site process xxxxx wxxxx or other water source that is capable of providing a quantity of raw water satisfying the needs of the Plant. Owner should consider providing a redundant water supply source. Owner will supply one process fresh water supply line terminating within five (5) feet of the point of entry designated by Design-Builder, and one potable supply line lines terminating within five (5) feet of the process building buildings as designated on the Phase II civil drawings and to the administration building at a point of entry designated by administration building contractor. Owner shall pay for a water pre-treatment system system, including any building or structure required to house such system, to be designed and constructed by Design-Builder and to be integrated into the Plant. The pre-treatment system will be designed to provide the Plant with the quantity and quality of raw and treated water needed to supply the Plant’s process needs. Owner shall maintain and use the water pre-treatment system, including the use of all chemicals specified for the operation of such water pre-treatment system, for the entirety of the warranty period set forth in the Design-Build agreement as such may be extended in accordance therewith. Owner’s failure to maintain and to properly use such water pre-treatment system for the warranty period set forth in the Design-Build Agreement shall void any and all warranties affected by such failure. The pre-treatment system shall be supplied by a vendor selected and approved by Design-Builder and shall meet specifications and designs approved by Design-Builder. The water pre-treatment system design will be required designed to meet the discharge requirements under the Plant’s wastewater discharge permit. Owner shall execute side-letter agreements with Design-Builder as necessary for the design and construction of such water pre-treatment systemsystem including any required building or structure. Design-Builder shall recover costs for the design and construction of such system and any required building or structure from the Owner at Design-Builder’s standard time plus material rates during the relevant time period and at the relevant locale.
Appears in 1 contract
Samples: Lump Sum Design Build Agreement (One Earth Energy LLC)