Weather Station Sample Clauses

Weather Station. KSPDCL will establish and maintain the weather station to monitor the solar irradiation and other necessary weather data.
AutoNDA by SimpleDocs
Weather Station. SPD will establish and maintain the weather station to monitor the solar irradiation and other necessary weather data.
Weather Station. (a) No later than sixty (60) Days prior to the Commercial Operation Date, Seller, at its own expense, shall install and maintain at least one stand-alone meteorological station at the Site to monitor, measure, communicate and report the meteorological data required under Section 3.17(b). Seller shall maintain and replace the meteorological station as necessary to provide accurate data with respect to the location of the Project. (b) Upon Commercial Operation, and continuing through the end of the Delivery Term, Seller shall record and maintain the following data: (i) real and reactive power production by the Project for each hour; (ii) changes in operating status, outages and maintenance events; (iii) any unusual conditions found during inspections; (iv) any significant events related to the operation of the Project; and (v) one (1) minute and hourly time-averaged measurements from data samples at ten (10) seconds or greater frequency for the following parameters at the Project: total global horizontal irradiance, total global radiation within the plane of the array, air temperature, relative humidity, wind direction and speed, precipitation, barometric pressure, back of module surface temperature, and other pertinent meteorological conditions. (c) Buyer shall have real-time access to the required meteorological data at a frequency not to exceed every five (5) minutes. Seller shall provide Buyer a report within thirty (30) days after the end of each month that provides the foregoing information for such month as well as any other additional information that Buyer reasonably requests regarding conditions at the Site and the operation of the Project that is collected and maintained by Seller in the ordinary course of Project operations. (d) Seller shall make available to Buyer all data from any weather monitoring portals Seller elects to install at the Site. (e) Subject to procedures agreed upon in the Operating Procedures, Buyer shall have the right to install equipment and associated communication infrastructure to enable Buyer to monitor, measure and communicate pertinent operation and weather data.
Weather Station. (a) No later than sixty (60) Days prior to the Commercial Operation Date, Seller, at its own expense, shall install and maintain at least one stand-alone meteorological station at the Site to monitor, measure, communicate and report the meteorological data required under Section 3.17(b). Seller shall maintain and replace the meteorological station as necessary to provide accurate data with respect to the location of the Project. (b) Upon Commercial Operation, and continuing through the end of the Delivery Term, Seller shall record and maintain the following data: (i) real and reactive power production by the Project for each hour; (ii) changes in operating status, outages and maintenance events; (iii)any unusual conditions found during inspections;
Weather Station. (a) No later than sixty (60) Days prior to the Commercial Operation Date, Seller, at its own expense, shall install and maintain at least one stand-alone meteorological station at the Site to monitor, measure, communicate and report the meteorological data required under Section 3.18(b). Seller shall maintain and replace the meteorological station as necessary to provide accurate data with respect to the location of the Project. (b) Upon the Commercial Operation Date, and continuing through the end of the Delivery Term, Seller shall record and maintain the following data: (i) real and reactive power production by the Project for each hour; (ii) changes in operating status, outages and maintenance events; of Energy in at least one of every two rolling Contract Years. If there is a Production Shortfall in any two rolling consecutive Contract Years, then Seller shall owe Buyer liquidated damages in an amount equal to (i) the Production Shortfall that occurred in the later of the two relevant Contract Years, multiplied by (ii) the Damages Rate (the “Production Guarantee Damages”).
Weather Station. 4.9.1 No later than sixty (60) Days prior to the Commercial Operation Date, Seller, at its own expense, shall install and maintain at least one stand- alone meteorological station at the Facility Site to monitor and report the
Weather Station. A Weather Station shall be installed with indications in the PCR. The station shall include as a minimum: relative humidity, ambient air temperature, wind speed and direction, precipitation meter, and barometric pressure.
AutoNDA by SimpleDocs
Weather Station. APSPCL will establish and maintain the weather station to monitor the solar irradiation and other necessary weather data.
Weather Station. The Service Provider shall establish a weather station in order to monitor and record, weather.

Related to Weather Station

  • Unbundled Loop Modifications (Line Conditioning 2.5.1 Line Conditioning is defined as routine network modification that BellSouth regularly undertakes to provide xDSL services to its own customers. This may include the removal of any device, from a copper Loop or copper Subloop that may diminish the capability of the Loop or Subloop to deliver high-speed switched wireline telecommunications capability, including xDSL service. Such devices include, load coils, excessive bridged taps, low pass filters, and range extenders. Excessive bridged taps are bridged taps that serves no network design purpose and that are beyond the limits set according to industry standards and/or the BellSouth’s TR 73600 Unbundled Local Loop Technical Specification. 2.5.2 BellSouth will remove load coils only on copper Loops and Subloops that are less than eighteen thousand (18,000) feet in length. 2.5.3 For any copper loop being ordered by NewPhone which has over six thousand (6,000) feet of combined bridged tap will be modified, upon request from NewPhone, so that the loop will have a maximum of six thousand (6,000) feet of bridged tap. This modification will be performed at no additional charge to NewPhone. Loop conditioning orders that require the removal of bridged tap that serves no network design purpose on a copper Loop that will result in a combined total of bridged tap between two thousand five hundred (2,500) and six thousand (6,000) feet will be performed at the rates set forth in Exhibit A. 2.5.4 NewPhone may request removal of any unnecessary and non-excessive bridged tap (bridged tap between zero (0) and two thousand five hundred (2,500) feet which serves no network design purpose), at rates pursuant to BellSouth’s SC Process as mutually agreed to by the Parties. 2.5.5 Rates for ULM are as set forth in Exhibit A. 2.5.6 BellSouth will not modify a Loop in such a way that it no longer meets the technical parameters of the original Loop type (e.g., voice grade, ADSL, etc.) being ordered. 2.5.7 If NewPhone requests ULM on a reserved facility for a new Loop order, BellSouth may perform a pair change and provision a different Loop facility in lieu of the reserved facility with ULM if feasible. The Loop provisioned will meet or exceed specifications of the requested Loop facility as modified. NewPhone will not be charged for ULM if a different Loop is provisioned. For Loops that require a DLR or its equivalent, BellSouth will provide LMU detail of the Loop provisioned. 2.5.8 NewPhone shall request Loop make up information pursuant to this Attachment prior to submitting a service inquiry and/or a LSR for the Loop type that NewPhone desires BellSouth to condition. 2.5.9 When requesting ULM for a Loop that BellSouth has previously provisioned for NewPhone, NewPhone will submit a SI to BellSouth. If a spare Loop facility that meets the Loop modification specifications requested by NewPhone is available at the location for which the ULM was requested, NewPhone will have the option to change the Loop facility to the qualifying spare facility rather than to provide ULM. In the event that BellSouth changes the Loop facility in lieu of providing ULM, NewPhone will not be charged for ULM but will only be charged the service order charges for submitting an order.