Common use of Working Drawings Clause in Contracts

Working Drawings. After the Space Plan has been approved by Landlord, Tenant shall supply the Architect and the Building Consultants with a complete listing of standard and non-standard equipment and specifications, including, without limitation, B.T.U. calculations, electrical requirements and special electrical receptacle requirements, to enable the Architect and the Building Consultants to complete the Working Drawings and shall cause the Architect and the Engineers to promptly complete the architectural and engineering drawings, and Architect shall compile a fully coordinated set of drawings, including but not limited to architectural, structural, mechanical, electrical, plumbing, fire sprinkler and life safety in a form which is complete to allow subcontractors to bid on the work and to obtain all applicable permits (collectively, the “Working Drawings”) and shall submit the same to Landlord for Landlord’s review and approval. Tenant shall supply Landlord with four (4) copies signed by Tenant of the Working Drawings. Landlord shall advise Tenant within ten (10) business days after Landlord’s receipt of the Working Drawings if Landlord, in good faith, determines that the same are approved or are unsatisfactory or incomplete. If Tenant is so advised, Tenant shall promptly revise the Working Drawings to correct any deficiencies or other matters Landlord may reasonably require.

Appears in 3 contracts

Samples: Sub Sublease (Carmot Therapeutics Inc.), Sub Sublease (Carmot Therapeutics Inc.), Workletter Agreement (Berkeley Lights, Inc.)

AutoNDA by SimpleDocs

Working Drawings. After the Space Plan has been approved by Landlord, Tenant shall supply the Architect and the Building Consultants with a complete listing of standard and non-standard equipment and specifications, including, without limitation, B.T.U. calculations, electrical requirements and special electrical receptacle requirements, to enable the Architect and the Building Consultants to complete the Working Drawings and shall cause the Architect and the Engineers to promptly complete the architectural and engineering drawings, and Architect shall compile a fully coordinated set of drawings, including but not limited to architectural, structural, mechanical, electrical, plumbing, fire sprinkler and life safety in a form which is complete to allow subcontractors to bid on the work and to obtain all applicable permits (collectively, the “Working Drawings”) and shall submit the same to Landlord for Landlord’s review and approval. Tenant shall supply Landlord with four (4) copies signed by Tenant of the Working Drawings. Landlord shall advise Tenant within ten (10) business days after LandlordXxxxxxxx’s receipt of the Working Drawings if Landlord, in good faith, determines that the same [ * ] = Certain confidential information contained in this document, marked by brackets, has been omitted and filed separately with the Securities and Exchange Commission pursuant to Rule 24b-2 of the Securities Exchange Act of 1934, as amended. are approved or are unsatisfactory or incomplete. If Tenant is so advised, Tenant shall promptly revise the Working Drawings to correct any deficiencies or other matters Landlord may reasonably require.

Appears in 1 contract

Samples: Work Agreement (Aduro Biotech, Inc.)

Working Drawings. After the Space Plan has been approved by Landlord, Tenant shall supply the Architect and the Building Consultants with a complete listing of standard and non-standard equipment and specifications, including, without limitation, B.T.U. calculations, electrical requirements and special electrical receptacle requirements, to enable the Architect and the Building Consultants to complete the Working Drawings and shall cause the Architect and the Engineers to promptly complete the architectural and engineering drawings, and Architect shall compile a fully coordinated set of drawings, including but not limited to including, as applicable, depending on the nature of the Tenant Work, architectural, structural, mechanical, electrical, plumbing, fire sprinkler and life safety in a form which is complete to allow subcontractors to bid on the work and to obtain all applicable permits (collectively, the “Working Drawings”) and shall submit the same to Landlord for Landlord’s review and approval. Tenant shall supply Landlord with four a copy (4which may be in electronic form), and at least one (1) copies signed by Tenant “hard” copy (which may be a half-sized set), of the Working Drawings. Landlord shall advise Tenant within ten (10) business days Business Days after Landlord’s receipt of the Working Drawings if Landlord, in good faith, determines that the same are approved or are unsatisfactory or incomplete. If Tenant is so advised, Tenant shall promptly revise the Working Drawings to correct any deficiencies or other matters Landlord may reasonably require.

Appears in 1 contract

Samples: Work Agreement (Caribou Biosciences, Inc.)

Working Drawings. After the Space Plan has been approved by Landlord, Tenant shall supply the Architect and the Building Consultants with a complete listing of standard and non-standard equipment and specifications, including, without limitation, B.T.U. calculations, electrical requirements and special electrical receptacle requirements, to enable the Architect and the Building Consultants to complete the Working Drawings and shall cause the Architect and the Engineers to promptly complete the architectural and engineering drawings, and Architect shall compile a fully coordinated set of drawings, including but not limited to architectural, structural, mechanical, electrical, plumbing, fire sprinkler and life safety in a form which is complete to allow subcontractors to bid on the work and to obtain all applicable permits (collectively, the “Working Drawings”) and shall submit the same to Landlord for Landlord’s review and approval. Tenant shall supply Landlord with four (4) copies signed by Tenant of the Working Drawings. Landlord shall advise Tenant within ten fifteen (1015) business days after Landlord’s receipt of the Working Drawings if Landlord, in good faith, determines that the same are approved or are unsatisfactory or incomplete. If Tenant is so advised, Tenant shall promptly revise the Working Drawings to correct any deficiencies or other matters Landlord may reasonably require.

Appears in 1 contract

Samples: Work Agreement (Zogenix, Inc.)

AutoNDA by SimpleDocs

Working Drawings. After the Space Plan has been approved by Landlord, Tenant shall supply the Architect and the Building Consultants with a complete listing of A–4 standard and non-standard equipment and specifications, including, without limitation, B.T.U. calculations, electrical requirements and special electrical receptacle requirementsrequirements for the Premises, to enable the Architect and the Building Consultants to complete the Working Drawings and shall cause the Architect and the Engineers Building Consultants to promptly complete the architectural and engineering drawingsdrawings for the Premises, and Architect shall compile a fully coordinated set of drawings, including but not limited to architectural, structural, mechanical, electrical, plumbing, fire sprinkler structural and life safety MEP working drawings in a form which is complete to allow subcontractors to bid on the work and to obtain all applicable permits (collectively, the “Working Drawings”) and shall submit the same to Landlord for Landlord’s review and approval, which approval shall not be unreasonably withheld, conditioned or delayed. Tenant shall supply Landlord with four (4) copies signed by Tenant of the Working Drawings. Landlord shall advise Tenant within ten (10) business days Business Days after Landlord’s receipt of the Working Drawings if Landlord, in good faith, determines that the same are approved (as so approved, the “Approved Working Drawings”) or are unsatisfactory or incomplete. If Tenant is so advisedadvised that the Working Drawings are unsatisfactory or incomplete, Tenant shall promptly revise the Working Drawings to correct any deficiencies or other matters Landlord may reasonably require.

Appears in 1 contract

Samples: Work Agreement (ForgeRock, Inc.)

Working Drawings. After the Space Plan has been approved (or deemed approved) by Landlord, Tenant shall supply the Architect and the Building Consultants with a complete listing of standard and non-standard equipment and specifications, including, without limitation, B.T.U. calculations, electrical requirements and special electrical receptacle requirements, to enable the Architect and the Building Consultants to complete the Working Drawings and shall cause the Architect and the Engineers to promptly complete the architectural and engineering drawings, and Architect shall compile a fully coordinated set of drawings, including but not limited to architectural, structural, mechanical, electrical, plumbing, fire sprinkler and life safety in a form which is complete to allow subcontractors to bid on the work and to obtain all applicable permits (collectively, the “Working Drawings”) and shall submit the same to Landlord for Landlord’s review and approval (or deemed approval). Tenant shall supply Landlord with four (4) copies signed by Tenant of the Working Drawings. Subject to Section 2 of this Workletter Agreement, Landlord shall advise Tenant within ten (10) business days after Landlord’s receipt of the Working Drawings if Landlord, in good faith, determines that the same are approved or are unsatisfactory or incomplete. If Tenant is so advised, Tenant shall promptly revise the Working Drawings to correct any deficiencies or other matters Landlord may reasonably require.

Appears in 1 contract

Samples: Workletter Agreement (Gritstone Oncology, Inc.)

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!