Active Power Output definition

Active Power Output means the active power during a Demand Period in kW (kilowatts) or multiples thereof, obtained by dividing the Active Energy produced in kWh (kilowatt hours) or multiples thereof during that period by the time interval of the said demand in hours.

Examples of Active Power Output in a sentence

  • With an Emergency Action setpoint issued and Operating in LFSM-U, the Power Park Module should not decrease its Active Power Output beyond the figure that has been instructed in response to high Frequency deviations, however the Power Park Module must respond to low Frequency deviations and increase Active Power Output according to the droop and deadband specified.

  • The performance is conditional to prime mover availability as well as reduced Maximum Active Power Output at low frequencies for certain generation technologies according to Article 8(1) (d) of the NC RfG.This feature contributes to maintaining and restoring system security.

  • A similar approach is defined for the LFC Block operation.Depending on the thresholds the NC LFCR gives the TSOs opportunities or obliges the TSOs to take additional measures including instructions for Power Generating Modules to change the Active Power Output if necessary for Operational Security.

  • The Active Power Output control may need to be demonstrated at otherApparent Power output levels (to be agreed by the Commissioning/Acceptance Test Panel) as the Power Park Module ramps up Active Power export to its Registered Capacity.

  • This behaviour of the coloured particles, to bind together to form colourless states, is known as confinement.The value of αs at the LHC energy scale (TeV) is αs ≈ 0.1, hence, the strong force dominates the other interactions and quantum corrections in perturbation theory are required to make precise predictions.

  • Active Power Output (as a % of available Active Power) Each Inverter of the Facility shall be able to provide frequency response as displayed in the above figure.

  • The RfG in Article 15.2(d) only allows TSOs to specify a value for a change in power output relative to the Active Power Output at the moment the frequency threshold was reached (or maximum capacity as defined by the TSO) between 1.5 – 10%, i.e. it does not allow the TSO to specify the levels that currently exist in the Grid Code.

  • The Active Power Output control may need to be demonstrated at other Apparent Power output levels (to beagreed by the Commissioning/Acceptance Test Panel) as the Power Park Module ramps up Active Power export to its Registered Capacity.

  • Algorithm 1: The Voltage Controller Procedure The PV model used for evaluation purposes is adopted from the simulation framework in reference (DiSC [6]), where active power output in normal operation is given by: Equation 2: Active Power Output in Normal Operation, > = �, < 0, ℎwhere µ is the efficiency of the solar cells, area they cover and the solar irradiation.

  • Optimization Results for Different Wind Speeds (a) and Active Power Output of Wind Turbine at 7 m/s Wind Speed After conducting the optimization study for the fixed FFR control, the aeroelastic code HAWC2 is employed in order to analyze the impact of this FFR control on the structural loads.

Related to Active Power Output

  • Reactive Power means the power component which does not produce work but is necessary to allow some equipment to operate, and is measured in kiloVolt Amperes Reactive (kVAR);

  • Infirm Power means electricity injected into the grid prior to the commercial operation of a Unit or Block of the Generating Station;

  • Electric power generator means an entity that proposes to

  • Stinger-steered automobile or watercraft transporter means an automobile or watercraft transporter

  • Biomass means the biodegradable fraction of products, waste and residues from biological origin from agriculture (including vegetal and animal substances), forestry and related industries including fisheries and aquaculture, as well as the biodegradable fraction of industrial and municipal waste;

  • Automobile or watercraft transporters means any tractor truck, lowboy, vehicle, or combination,

  • MGD means million gallons per day. "mg/l" means milligrams per liter. "ug/l" means micrograms per liter. "ng/l" means nanograms per liter. "S.U." means standard pH unit. "kg/day" means kilograms per day.