Power augmentation definition

Power augmentation means technologies that increase the capacity and the heat rate of the plant above the capacity and heat rate of the base load gas plant. These include, but are not limited to, duct burning and some forms of steam augmentation.¶
Power augmentation means an increase in the gas turbine engine shaft output, or a decrease in turbine fuel consumption, by the addition of energy recovered from exhaust heat.
Power augmentation means the generation of incremental Energy from one or more of the Combustion Turbines through the injection of steam from the Steam Turbine or the heat recovery steam generators into the combustor(s) of such Combustion Turbine(s).

Examples of Power augmentation in a sentence

  • Power augmentation systems — 1 — Operation and applications; Water injection, water methanol; Afterburner systems.

  • Power augmentation up to 14% has been recorded which is noteworthy in responding to the electricity demand in hot months.

  • Duct fining is estimated to be necessary for only 1,000 hours per year and Duct Firing with Power augmentation is estimated to be necessary only 200 hours per year.

  • Power augmentation such as fogging, evaporative cooling, and steam injection may be used provided it meets all OEM requirements.

  • The storage is charged with the compressed air by the auxiliary motor-driven compressor during off-peak hours utilizing renewable resources or available nuclear or coal capacities.• Power augmentation mode of operation, when a CT/CC plant power is augmented during peak hours by additional airflows supplied by the auxiliary compressor operating simultaneously with a CT/CC plant in the event that sufficient air is not available from storage.

  • Power augmentation methods may include:(a) Combustion turbine inlet air cooling methods;(b) Duct firing; (c) Other ways of temporarily increasing the output of Combined Cycle Generation Resources; and(d) For Qualifying Facilities (QFs), an LSL that represents the minimum energy available for Dispatch by SCED, in MW, from the Combined Cycle Generation Resource based on the minimum stable steam delivery to the thermal host plus a justifiable reliability margin that accounts for changes in ambient conditions.

  • Power augmentation, other than the inlet air cooled system via the evaporative coolers, would not be used.

  • Diffusers (or shrouds) are aerodynamic structures, commonly employed for the purpose of Power augmentation of hydrokinetic turbines.

  • Power augmentation equipment (SPRINT and inlet chilling systems) are commissioned and tuned.

  • Power augmentation steam injection rates and quarterly hours of operation.


More Definitions of Power augmentation

Power augmentation means the additional generation of electricity at the Linden 6 Facility for sale to Third Parties as a result of the injection of steam into and the consumption of incremental fuel by the Linden 6 Facility.
Power augmentation means the additional generation of Electricity at the Facility for sale to Third Parties as a result of the injection of low pressure steam and incremental Fuel into the Facility.

Related to Power augmentation

  • Power Plant means a facility for the generation of

  • Co-generation means the sequential production of electricity

  • Generation Interconnection Request means a request by a Generation Interconnection Customer pursuant to Tariff, Part IV, subpart A, to interconnect a generating unit with the Transmission System or to increase the capacity of a generating unit interconnected with the Transmission System in the PJM Region.

  • Generation Interconnection Customer means an entity that submits an Interconnection Request to interconnect a new generation facility or to increase the capacity of an existing generation facility interconnected with the Transmission System in the PJM Region. Generation Interconnection Request:

  • Interconnection Feasibility Study means either a Generation Interconnection Feasibility Study or Transmission Interconnection Feasibility Study.

  • Module means specific portion of the Application Software designated as such in the Documentation made available to the Customer under the Notification Form.

  • Cannabis processing facility means a person that:

  • high-efficiency cogeneration means cogeneration meeting the criteria laid down in Annex II;

  • Interconnection Point means the point(s) of connection(s) at which the project is connected to the grid i.e. it shall be at 11 / 22 kV bus bar level of substation of MSEDCL.

  • Functional Specifications means the descriptions of features and functions of the Application as expressly set forth in Quote.

  • Large Facility Interconnection Procedures or “LFIP”) shall mean the interconnection procedures applicable to an Interconnection Request pertaining to a Large Generating Facility that are included in Attachment X of the NYISO OATT. Standard Large Generator Interconnection Agreement (“LGIA”) shall mean this Agreement, the form of interconnection agreement applicable to an Interconnection Request pertaining to a Large Generating Facility, that is included in Attachment X of the NYISO OATT. System Deliverability Upgrades shall mean the least costly configuration of commercially available components of electrical equipment that can be used, consistent with Good Utility Practice and Applicable Reliability Requirements, to make the modifications or additions to Byways and Highways and Other Interfaces on the existing New York State Transmission System and Distribution System that are required for the proposed project to connect reliably to the system in a manner that meets the NYISO Deliverability Interconnection Standard at the requested level of Capacity Resource Interconnection Service. System Protection Facilities shall mean the equipment, including necessary protection signal communications equipment, required to (1) protect the New York State Transmission System from faults or other electrical disturbances occurring at the Large Generating Facility and (2) protect the Large Generating Facility from faults or other electrical system disturbances occurring on the New York State Transmission System or on other delivery systems or other generating systems to which the New York State Transmission System is directly connected. System Upgrade Facilities shall mean the least costly configuration of commercially available components of electrical equipment that can be used, consistent with Good Utility Practice and Applicable Reliability Requirements, to make the modifications to the existing transmission system that are required to maintain system reliability due to: (i) changes in the system, including such changes as load growth and changes in load pattern, to be addressed in the form of generic generation or transmission projects; and (ii) proposed interconnections. In the case of proposed interconnection projects, System Upgrade Facilities are the modifications or additions to the existing New York State Transmission System that are required for the proposed project to connect reliably to the system in a manner that meets the NYISO Minimum Interconnection Standard. Tariff shall mean the NYISO Open Access Transmission Tariff (“OATT”), as filed with the Commission, and as amended or supplemented from time to time, or any successor tariff. Trial Operation shall mean the period during which Developer is engaged in on-site test operations and commissioning of the Large Generating Facility prior to Commercial Operation.

  • Fixed wing turbine powered aircraft means an aircraft that:

  • Small wireless facility means a wireless facility that meets both of the following qualifications:

  • Life-of-the-unit, firm power contractual arrangement means a unit participation power sales agreement under which a utility or industrial customer reserves, or is entitled to receive, a specified amount or percentage of nameplate capacity and associated energy from any specified unit and pays its proportional amount of such unit's total costs, pursuant to a contract: