Loop Provisioning Involving Integrated Digital Loop Carriers 2.6.1 Where Xxxx has requested an Unbundled Loop and BellSouth uses IDLC systems to provide the local service to the End User and BellSouth has a suitable alternate facility available, BellSouth will make such alternative facilities available to Xxxx. If a suitable alternative facility is not available, then to the extent it is technically feasible, BellSouth will implement one of the following alternative arrangements for Xxxx (e.g. hairpinning): 1. Roll the circuit(s) from the IDLC to any spare copper that exists to the customer premises. 2. Roll the circuit(s) from the IDLC to an existing DLC that is not integrated. 3. If capacity exists, provide "side-door" porting through the switch. 4. If capacity exists, provide "Digital Access Cross Connect System (DACS)- door" porting (if the IDLC routes through a DACS prior to integration into the switch). 2.6.2 Arrangements 3 and 4 above require the use of a designed circuit. Therefore, non- designed Loops such as the SL1 voice grade and UCL-ND may not be ordered in these cases. 2.6.3 If no alternate facility is available, and upon request from Xxxx, and if agreed to by both Parties, BellSouth may utilize its Special Construction (SC) process to determine the additional costs required to provision facilities. Xxxx will then have the option of paying the one-time SC rates to place the Loop.
Reverse ADSL Loops If a CLEC’s ADSL Transmission Unit (including those integrated into DSLAMs) is attached to Sprint’s Network and if an ADSL Copper Loop should start at an outside location, and is looped through a host or remote, and then to the subscriber, the copper plant from the outside location to the Sprint host or remote central office must be a facility dedicated to ADSL transmission only and not part of Sprint’s regular feeder or distribution plant.
Synchronization, Commissioning and Commercial Operation 4.1.1 The Power Producer shall give at least fifteen (15) days written notice to the SLDC / ALDC / DISCOM as the case may be, of the date on which it intends to synchronize the Power Project to the Grid System. 4.1.2 Subject to Article 4.1.1, the Power Project may be synchronized by the Power Producer to the Grid System when it meets all the connection conditions prescribed in the Grid Code and otherwise meets all other Indian legal requirements for synchronization to the Grid System. 4.1.3 The synchronization equipment and all necessary arrangements / equipment including Remote Terminal Unit (RTU) for scheduling of power generated from the Project and transmission of data to the concerned authority as per applicable regulation shall be installed by the Power Producer at its generation facility of the Power Project at its own cost. The Power Producer shall synchronize its system with the Grid System only after the approval of GETCO / SLDC / ALDC and GEDA. 4.1.4 The Power Producer shall immediately after each synchronization / tripping of generator, inform the sub-station of the Grid System to which the Power Project is electrically connected in accordance with applicable Grid Code. 4.1.5 The Power Producer shall commission the Project within SCOD. 4.1.6 The Power Producer shall be required to obtain Developer and/ or Transfer Permission, Key Plan drawing etc, if required, from GEDA. In cases of conversion of land from Agricultural to Non-Agriculture, the commissioning shall be taken up by GEDA only upon submission of N.A. permission by the Power Producer. 4.1.7 The Power Producer shall be required to follow the Forecasting and Scheduling procedures as per the Regulations issued by Hon’ble GERC from time to time. It is to clarify that in terms of GERC (Forecasting, Scheduling, Deviation Settlement and Related Matters of Solar and Wind Generation Sources) Regulations, 2019 the procedures for Forecasting, Scheduling & Deviation Settlment are applicable to all solar generators having combined installed capacity above 1 MW connected to the State Grid / Substation including those connected via pooling stations.
Financial Services Compensation Scheme We are a participant in the Financial Services Compensation Scheme (the “FSCS”). As a retail client you may be eligible to claim compensation from the FSCS in certain circumstances if we, any approved bank, our nominee company or eligible custodian are in default. Most types of investment business are covered in full for the first £85,000 of any eligible claim. Not every investor is eligible to claim under this scheme: for further information please contact us, or the FSCS directly at xxx.xxxx.xxx.xx.
Certification as Small Contractor or Minority Business Enterprise This paragraph was intentionally left blank.
Annual Business Plan (a) On or before November 15th of each year during the term of this Agreement, Manager shall prepare and submit to Owner for Owner's prior approval an annual business and leasing plan in accordance with the requirements of EXHIBIT D hereto (as such EXHIBIT D may be modified by Owner from time to time) (the "ANNUAL BUSINESS PLAN"). The Annual Business Plan shall be a comprehensive plan for the management, operation, leasing, repair, maintenance and promotion of the Property and for the other matters set forth on EXHIBIT D. Manager shall consult the Owner concerning the proposed Annual Business Plan and shall promptly incorporate therein such changes as Owner may direct. The Annual Business Plan, and all budgets contained therein, shall be in a form consistent with the Reporting Package. (b) Manager shall: (i) perform its duties hereunder in accordance with the Approved Annual Business Plan; and (ii) use all reasonable efforts to ensure that the actual costs of maintaining and operating the Property do not exceed the operating budget (the "OPERATING BUDGET") which is a part of the Approved Annual Business Plan either in total or in any one accounting category. All actual expenses must be charged to the proper account on a basis consistent with the Operating Budget classifications and Reporting Package. Except in case of emergencies which could reasonably pose a threat of injury to persons or property, in which event Manager shall inform Owner of such emergency within two (2) business days, no expense may be reclassified except as needed to correct an inadvertent error. Manager will secure Owner's prior approval for any expenditure that will result in a variance of the greater of $5,000 or 5% of the annual budgeted amount in any one accounting line item of the Operating Budget. In addition, Manager shall obtain Owner's prior approval for any expenditure in excess of $5,000, regardless of whether such expenditure is set forth in the Approved Annual Business Plan. (c) Owner shall have the right to require changes in the Approved Annual Business Plan from time to time; provided, however, that Owner shall provide Manager with at least fifteen (15) days' notice of such changes.
Verizon Operations Support Systems Verizon systems for pre- ordering, ordering, provisioning, maintenance and repair, and billing.
International Olympic Committee; International Red Cross and Red Crescent Movement As instructed from time to time by ICANN, the names (including their IDN variants, where applicable) relating to the International Olympic Committee, International Red Cross and Red Crescent Movement listed at xxxx://xxx.xxxxx.xxx/en/resources/registries/reserved shall be withheld from registration or allocated to Registry Operator at the second level within the TLD. Additional International Olympic Committee, International Red Cross and Red Crescent Movement names (including their IDN variants) may be added to the list upon ten (10) calendar days notice from ICANN to Registry Operator. Such names may not be activated in the DNS, and may not be released for registration to any person or entity other than Registry Operator. Upon conclusion of Registry Operator’s designation as operator of the registry for the TLD, all such names withheld from registration or allocated to Registry Operator shall be transferred as specified by ICANN. Registry Operator may self-‐allocate and renew such names without use of an ICANN accredited registrar, which will not be considered Transactions for purposes of Section 6.1 of the Agreement.
Emergency Mode Operation Plan Contractor must establish a documented plan to enable continuation of critical business processes and protection of the security of electronic County PHI or PI in the event of an emergency. Emergency means any circumstance or situation that causes normal computer operations to become unavailable for use in performing the work required under this Agreement for more than twenty-four (24) hours.
Information Technology Enterprise Architecture Requirements If this Contract involves information technology-related products or services, the Contractor agrees that all such products or services are compatible with any of the technology standards found at xxxxx://xxx.xx.xxx/iot/2394.htm that are applicable, including the assistive technology standard. The State may terminate this Contract for default if the terms of this paragraph are breached.