Analyser response Sample Clauses

The 'Analyser response' clause defines the obligations and procedures for a party to provide a formal reply or feedback after reviewing a document, data, or proposal. Typically, this clause outlines the timeframe within which the response must be given, the format or method of communication required, and any specific issues or points that must be addressed in the response. For example, it may require a party to confirm receipt, raise objections, or request clarifications within a set number of days. The core function of this clause is to ensure timely and structured communication between parties, thereby reducing misunderstandings and keeping the process on track.
Analyser response. The output of the analysers shall be recorded on a strip chart recorder or measured with an equivalent data acquisition system with the exhaust gas flowing through the analysers at least during the last three minutes of each mode. If bag sampling is applied for the diluted CO and CO2 measurement (see Annex 4A, Appendix 1, paragraph 1.4.4.), a sample shall be bagged during the last three minutes of each mode, and the bag sample analysed and recorded.
Analyser response. At the start of the engine the measuring equipment shall be started, simultaneously: (a) Start collecting or analysing dilution air, if a full flow dilution system is used; (b) Start collecting or analysing raw or diluted exhaust gas, depending on the method used; (c) Start measuring the amount of diluted exhaust gas and the required temperatures and pressures; (d) Start recording the exhaust gas mass flow rate, if raw exhaust gas analysis is used; (e) Start recording the feedback data of speed and torque of the dynamometer. If raw exhaust measurement is used, the emission concentrations (HC, CO and NOx) and the exhaust gas mass flow rate shall be measured continuously and stored with at least 2 Hz on a computer system. All other data may be recorded with a sample rate of at least 1 Hz. For analogue analysers the response shall be recorded, and the calibration data may be applied online or offline during the data evaluation. If a full flow dilution system is used, HC and NOx shall be measured continuously in the dilution tunnel with a frequency of at least 2 Hz. The average concentrations shall be determined by integrating the analyser signals over the test cycle. The system response time shall be no greater than 20 s, and shall be coordinated with CVS flow fluctuations and sampling time/test cycle offsets, if necessary. CO and CO2 shall be determined by integration or by analysing the concentrations in the sample bag collected over the cycle. The concentrations of the gaseous pollutants in the dilution air shall be determined by integration or by collection in the background bag. All other parameters that need to be measured shall be recorded with a minimum of one measurement per second (1 Hz).
Analyser response. At the start of the test sequence, the measuring equipment shall be started, simultaneously: (a) start collecting or analyzing dilution air, if a full flow dilution system is used; (b) start collecting or analyzing raw or diluted exhaust gas, depending on the method used; (c) start measuring the amount of diluted exhaust gas and the required temperatures and pressures; (d) start recording the exhaust gas mass flow rate, if raw exhaust gas analysis is used; (e) start recording the feedback data of speed and torque of the dynamometer. If raw exhaust measurement is used, the emission concentrations ((NM)HC, CO and NOx) and the exhaust gas mass flow rate shall be measured continuously and stored with at least 2 Hz on a computer system. All other data may be recorded with a sample rate of at least 1 Hz. For analogue analysers the response shall be recorded, and the calibration data may be applied online or offline during the data evaluation. If a full flow dilution system is used, HC and NOx shall be measured continuously in the dilution tunnel with a frequency of at least 2 Hz. The average concentrations shall be determined by integrating the analyser signals over the test cycle. The system response time shall be no greater than 20 s, and shall be coordinated with CVS flow fluctuations and sampling time/test cycle offsets, if necessary. CO, CO2, and NMHC may be determined by integration of continuous measurement signals or by analyzing the concentrations in the sample bag, collected over the cycle. The concentrations of the gaseous pollutants in the dilution air shall be determined by integration or by collecting into the background bag. All other parameters that need to be measured shall be recorded with a minimum of one measurement per second (1 Hz).
Analyser response. At the start of the engine or test sequence, if the cycle is started directly from the preconditioning,, the measuring equipment must be started, simultaneously: – start collecting or analysing dilution air; – start collecting or analysing diluted exhaust gas; – start measuring the amount of diluted exhaust gas (CVS) and the required temperatures and pressures; – start recording the feedback data of speed and torque of the dynamometer. HC and NOx must be measured continuously in the dilution tunnel with a frequency of 2 Hz. The average concentrations must be determined by integrating the analyser signals over the test cycle. The system response time must be no greater than 20 s, and must be coordinated with CVS flow fluctuations and sampling time/test cycle offsets, if necessary. CO, CO2, NMHC and CH4 must be determined by integration or by analysing the concentrations in the sample bag, collected over the cycle. The concentrations of the gaseous pollutants in the dilution air must be determined by integration or by collecting into the background bag. All other values must be recorded with a minimum of one measurement per second (1 Hz).
Analyser response. The output of the analysers must be recorded on a strip chart recorder or measured with an equivalent data acquisition system with the exhaust gas flowing through the analysers throughout the test cycle.

Related to Analyser response

  • Timing of Company Response The Company shall respond to such claimant within 90 days after receiving the claim. If the Company determines that special circumstances require additional time for processing the claim, the Company can extend the response period by an additional 90 days by notifying the claimant in writing, prior to the end of the initial 90-day period, that an additional period is required. The notice of extension must set forth the special circumstances and the date by which the Company expects to render its decision.

  • Emergency Response Partners must develop, maintain, and carry out a response plan for public water system emergencies, including disease outbreaks, spills, operational failures, and water system contamination. Partners must notify DWS in a timely manner of emergencies that may affect drinking water supplies.

  • Company’s Response Upon receipt by the Company of a copy of a Purchase Notice, the Company shall as soon as practicable, but in no event later than one (1) Trading Day after receipt of such Purchase Notice, send via facsimile (or otherwise deliver), a confirmation of receipt of such Purchase Notice in the form attached hereto as Exhibit B (a "Company Confirmation of Purchase Notice") to (1) the Buyer and (2) along with a copy of the Purchase Notice, the Company's designated transfer agent (the "Transfer Agent"), which confirmation shall constitute an irrevocable instruction to the Transfer Agent to process such Purchase Notice in accordance with the terms herein. Upon receipt by the Transfer Agent of a copy of the executed Purchase Notice and a copy of the applicable Company Confirmation of Purchase Notice, the Transfer Agent shall, on the first (1st) Trading Day following the date of receipt of the Company Confirmation of Purchase Notice, (A) provided the Transfer Agent is participating in The Depository Trust Company's ("The DTC") Fast Automated Securities Transfer Program, credit such aggregate number of shares of Common Stock to which the Buyer shall be entitled to the Buyer's or its designee's balance account with The DTC through its Deposit Withdrawal At Custodian ("DWAC") system, or (B) if the Transfer Agent is not participating in The DTC Fast Automated Securities Transfer Program and DWAC system, issue and surrender to a common carrier for overnight delivery to the address as specified in the Purchase Notice, a certificate, registered in the name of the Buyer or its designee, for the number of shares of Common Stock to which the Buyer shall be entitled.

  • Line Item Question Response 46 Do your warranties cover all products, parts, and labor? Warranties are those supplied by the equipment manufacturers. Generally cover parts and labor. * 47 Do your warranties impose usage restrictions or other limitations that adversely affect coverage? Warranty will not cover abuse or lack of maintenance. * 48 Do your warranties cover the expense of technicians' travel time and mileage to perform warranty repairs? Yes * 49 Are there any geographic regions of the United States or Canada (as applicable) for which you cannot provide a certified technician to perform warranty repairs? How will Sourcewell participating entities in these regions be provided service for warranty repair? We have coverage in the United States. * 50 Will you cover warranty service for items made by other manufacturers that are part of your proposal, or are these warranties issues typically passed on to the original equipment manufacturer? We warranty any work we preform. The equipment is covered by the original equipment manufacturer. * 51 What are your proposed exchange and return programs and policies? Special order items are not returnable and will not be exchanged. If a manufacture will take back an item they consider returnable, the return must have an RMA and be returned within 90 days in the original carton. All freight, restocking, damage plus a service fee will be deducted form the credit for equipment. * 52 Describe any service contract options for the items included in your proposal. We offer preventative maintenance contracts for refrigeration equipment in Texas. DFW, Houston, Beaumont and Austin. * 53 Describe your payment terms and accepted payment methods. Standard payment terms are Net 30 days. To be considered for an open account, all new customers will be required to complete a New Customer Application and provide tax exemption certification if applicable. All applicants are subject to Strategic's Credit Terms and Policies and must meet criteria specified therein. Finance charges of 1/5% per month (18% APR) or the maximum rate that an applicant may lawfully contract to pay, whichever is less, on any payment Seller considers past due until collected. Accepted payment methods include check, ACH, wire transfer, credit card * 54 Describe any leasing or financing options available for use by educational or governmental entities. TriMark Strategic has developed business relationships with several reputable third-party leasing companies and can provide Sourcewell customers with information regarding this option upon request. * 55 Describe any standard transaction documents that you propose to use in connection with an awarded contract (order forms, terms and conditions, service level agreements, etc.). Upload a sample of each (as applicable) in the document upload section of your response. Strategic will require a valid Purchase Order from Sourcewell customers. Upon acceptance, Strategic will agree to the terms and conditions set forth in the Purchase Order. All quotes submitted by Strategic to Sourcewell customers will be on a standard Quotation Form and will have this statement regarding the Terms of Sale: "This Quote shall be subject to Trimark's Terms of Sale http//▇▇▇.▇▇▇▇▇▇▇▇▇▇.▇▇▇/▇▇▇▇▇▇▇▇▇/▇▇▇▇▇▇▇▇▇▇▇▇▇/▇▇▇▇/▇▇▇▇▇▇▇-▇▇▇▇▇- and-Conditions-of-Sale.pdf, which are incorporated herein by reference. The customer's Purchase Order terms and conditions shall govern. *

  • Incident Response Operator shall have a written incident response plan that reflects best practices and is consistent with industry standards and federal and state law for responding to a data breach, breach of security, privacy incident or unauthorized acquisition or use of any portion of Data, including PII, and agrees to provide LEA, upon request, an executive summary of the written incident response plan.