Approved Services; Additional Services Registry Operator shall be entitled to provide the Registry Services described in clauses (a) and (b) of the first paragraph of Section 2.1 in the Specification 6 attached hereto (“Specification 6”) and such other Registry Services set forth on Exhibit A (collectively, the “Approved Services”). If Registry Operator desires to provide any Registry Service that is not an Approved Service or is a material modification to an Approved Service (each, an “Additional Service”), Registry Operator shall submit a request for approval of such Additional Service pursuant to the Registry Services Evaluation Policy at xxxx://xxx.xxxxx.xxx/en/registries/rsep/rsep.html, as such policy may be amended from time to time in accordance with the bylaws of ICANN (as amended from time to time, the “ICANN Bylaws”) applicable to Consensus Policies (the “RSEP”). Registry Operator may offer Additional Services only with the written approval of ICANN, and, upon any such approval, such Additional Services shall be deemed Registry Services under this Agreement. In its reasonable discretion, ICANN may require an amendment to this Agreement reflecting the provision of any Additional Service which is approved pursuant to the RSEP, which amendment shall be in a form reasonably acceptable to the parties.
Penalties for Non-compliance to Service Level Agreement Where the Supplier/Service Provider fails to deliver the Goods/Services within the agreed and accepted milestone timelines and provided that the cause of the delay was not due to a fault of Transnet, penalties shall be imposed at …………………………………………………… .
Primary Frequency Response Developer shall ensure the primary frequency response capability of its Large Generating Facility by installing, maintaining, and operating a functioning governor or equivalent controls. The term “functioning governor or equivalent controls” as used herein shall mean the required hardware and/or software that provides frequency responsive real power control with the ability to sense changes in system frequency and autonomously adjust the Large Generating Facility’s real power output in accordance with the droop and deadband parameters and in the direction needed to correct frequency deviations. Developer is required to install a governor or equivalent controls with the capability of operating: (1) with a maximum 5 percent droop ± 0.036 Hz deadband; or (2) in accordance with the relevant droop, deadband, and timely and sustained response settings from an approved Applicable Reliability Standard providing for equivalent or more stringent parameters. The droop characteristic shall be: (1) based on the nameplate capacity of the Large Generating Facility, and shall be linear in the range of frequencies between 59 and 61 Hz that are outside of the deadband parameter; or (2) based on an approved Applicable Reliability Standard providing for an equivalent or more stringent parameter. The deadband parameter shall be: the range of frequencies above and below nominal (60 Hz) in which the governor or equivalent controls is not expected to adjust the Large Generating Facility’s real power output in response to frequency deviations. The deadband shall be implemented: (1) without a step to the droop curve, that is, once the frequency deviation exceeds the deadband parameter, the expected change in the Large Generating Facility’s real power output in response to frequency deviations shall start from zero and then increase (for under-frequency deviations) or decrease (for over-frequency deviations) linearly in proportion to the magnitude of the frequency deviation; or (2) in accordance with an approved Applicable Reliability Standard providing for an equivalent or more stringent parameter. Developer shall notify NYISO that the primary frequency response capability of the Large Generating Facility has been tested and confirmed during commissioning. Once Developer has synchronized the Large Generating Facility with the New York State Transmission System, Developer shall operate the Large Generating Facility consistent with the provisions specified in Articles 9.5.5.1 and 9.5.5.2 of this Agreement. The primary frequency response requirements contained herein shall apply to both synchronous and non-synchronous Large Generating Facilities.
Substance Abuse Treatment Information Substance abuse treatment information shall be maintained in compliance with 42 C.F.R. Part 2 if the Party or subcontractor(s) are Part 2 covered programs, or if substance abuse treatment information is received from a Part 2 covered program by the Party or subcontractor(s).