Building Information Sample Clauses

Building Information. This clause applies to all recipients of SBU building information, including offerors, bidders, awardees, contractors, subcontractors, lessors, suppliers and manufacturers.
Building Information. This clause applies to all recipients of CUI building information (which falls within the CUI Physical Security category), including offerors, bidders, awardees, contractors, subcontractors, lessors, suppliers and manufacturers. Marking CUI. Contractors must submit any contractor-generated documents that contain building information to GSA for review and identification of any CUI building information that may be included. In addition, any documents GSA identifies as containing CUI building information must be marked in accordance with the Order and the Marking Controlled Unclassified Information Handbook (the current version may be found at xxxxx://xxx.xxxxxxxx.xxx/files/cui/00000000-cui-marking-handbook-v1-1.pdf) before the original or any copies are disseminated to any other parties. If CUI content is identified, the CO may direct the contractor, as specified elsewhere in this contract, to imprint or affix CUI document markings (CUI) to the original documents and all copies, before any dissemination, or authorized GSA employees may mark the documents.
Building InformationIn addition to any requirements set forth in the Amended Lease, Landlord agrees to provide certain building information and notices (the “Building Information”) to Tenant as set forth in this Article. Tenant shall keep any Building Information confidential and such Building Information shall be subject to Article 39 of the Amended Lease.
Building InformationLandlord shall provide to Tenant (i) a list of all HVAC units that serve the Premises such list to include, to the extent available, unit number, maker of unit, type of unit, model number, serial number and size of unit, (ii) any historical HVAC maintenance records, (iii) copies of past utilities bills, (iv) a copy of any CC&Rs relating to the Building and (v) to the extent in Landlord’s possession, full CAD drawings, including mechanical and electrical.
Building Information a) Lot A – Courthouse Complex – Building Information b) Lot BDowntown District – Building Information c) Lot C – 33rd Street District – Building Information d) Lot D – Central District – Building Information
Building Information. See floor plans-Attachment N. Janitorial services will include all interior areas of the buildings with the exception of mechanical storage, unauthorized areas, and specified Day Service and Detention areas. The public entrance is on the 1st floor, 000 X. Xxxxxxx Street. The service dock for unloading/loading of supplies and trash dumpsters is located on the ground floor level. Most floors have a substantial amount of file and conference rooms. Some floors have more public space versus staff areas, especially those floors which contain courtrooms. The Sheriff’s Office has offices, classrooms and a presence on several floors, specifically the ground floor which includes a fitness room and associated locker rooms. There are eleven (11) elevators. Six (6) elevators are for public use, one (1) elevator is for service (janitorial) use, two (2) elevators for Judge’s use and two (2) elevators for Detention/Sheriff’s use. There are five (5) sets of stairs in the Courthouse. Accessibility to stairs and elevators changes depending on the floor you are on. A public vending area will be housed on the 1st floor. See additional information below. Ground Floor 9,886 sq ft 1st Floor 36,168 sq ft 2nd Floor 35,442 sq ft 3rd Floor 36,083 sq ft 4th Floor 20,689 sq ft 5th Floor 25,481 sq ft 6th Floor 20,554 sq ft 7th Floor 19,733 sq ft 8th Floor 7,564 sq ft 9th Floor 21,504 sq ft Total 223,104 sq ft FIXTURES: Toilets 159* Urinals 30* Sinks 108* *Fixtures in Day Service or Sheriff Detention Trustee areas not deducted from quantities. RESTROOM FIXTURES: Typical fixtures include chrome or stainless steel automatic under mount counter soap dispensing units, or free flow pump style soap dispensers, automatic faucets, multi fold paper towel dispensers, wall mounted trash receptacles, wall mounted sanitary trash containers, dual single roll toilet paper dispensers, stainless steel baby stations and partitions. Automatic flushing toilets and the Men’s restrooms will have waterless urinals. Restroom walls are a combination of painted drywall, wall paper, faux rock resin or tile surfaces. Type Location Terrazzo Flooring All Floors in Public Areas, on Stairs and Landings Carpet Tiles All Floors in Office Areas Sheet Linoleum Flooring All Floors in Break Rooms, Labs, Vending, Elevators Rubber Flooring All Floors on Stairways and Landings Ground Floor Fitness Room Painted Concrete Ground Floor General Areas Tile (1’ x 2’) with Grout All Floors in Restrooms and Locker Rooms
Building InformationCopies of any and all architectural and engineering reports, as-built plans and specifications, the most recent as-built surveys, permits, licenses, applications, violation notices, certificates of occupancy, pending letters of intent for leasing space in the Real Property, a list of all current litigation and pending claims, inspection reports and/or approvals concerning the Property, all agreements with any abutters to the Property, including summaries of any existing agreements with said abutters that are oral rather than written.
Building Information. Emeline - The Emeline Building is two stories high and has a low-sloped roof. A link struc- ture connects the Building to an adjacent building - we understand the roof of this link structure is not part of the planned reroof project. The parapet walls appear to consist of cast-in-place concrete and the roof deck appears to consist of cast gypsum over steel joists. Several vents and small pieces of equipment are positioned on the roof. The roof surface slopes mildly to scupper drains on one side. These are some areas of incomplete surface drainage. During a previous visit to this roof in 2004, a small test cut (made and repaired by others) indicated two existing roof coverings. It is not presently known if any of these existing roof coverings contain asbestos. Some building drawings were provided to us. 0000 Xxxxxxxx Xxxxxx, Xxxxx X Xxxxxxx, XX 00000-0000 (000) 000-0000 Fax (000) 000-0000 Roof and Consultants Xx. Xxxx Xxxxxxx RE: Reroof and Sealant Replacements - Various Projects August 9,2005 Government Center - The Santa Cruz County Government Center is a five-story structure with precast concrete columns, beams, and exterior wall panels. The sealant joints planned for replacement include the exterior joints between the concrete beams, columns and wall panels. The exterior windows have rubber gaskets around them and are not part of the planned sealant replacement work.
Building InformationGeneral Information