Building Sections showing interior spaces and scale of the ceiling heights relative to roof structure and anticipated roof framing depths.
Building Sections and Large scale wall sections as appropriate to this level of document development and as required to establish vertical controls for the Project. Include clear graphics, and notes on construction assemblies and systems to be used, dimensions, heights. Provide larger scale detailing to delineate solutions for connections.
Building Sections. Dimensions: Vertical dimensions relating to floor, ceiling, roof, top of steel Provide grid lines and cross reference to floor plans Materials: Note and indicate material as well as listed fire rated assemblies G. Reflected Ceiling Plan Provide ceiling construction. Show ceiling breaks, or change in height Show ceiling pattern, diffusers, light fixtures, exit signage and access panels H. Enlarged Floor Plan(s) Toilet Room Plans: Plumbing fixtures, stall layout, and handicap accessibility Verify plumbing fixture count with code requirements. Kitchens: Kitchen equipment layout I. Interior Elevations Toilet Room Elevations: Plumbing fixture heights and handicap accessibility Indicate wall finish materials X. Xxxxxxxxx Room Finish Schedule: Show interior finishes Door Schedule: Door types, sizes and fire rating, door hardware Window Schedule: Window types, frames, labels, glazing and sizes K. Architectural Details Stairs: Riser and tread dimensions, headroom clearance, and handrail details and attachment details Guardrails: Height and distance between intermediate rails and attachment details Ramps: Slope and length and handrails Wall Types: Fire rated construction, corridor walls, shaft walls, area separation walls, occupancy separation walls. Indicate listed assemblies for fire rated construction. Specify fire penetration sealants at rated walls. L. Structural Notes Live Loads: Floors, stairs, corridors, roof, snow, earthquake and wind Dead Loads: Material weight, mechanical and electrical weight, wet-pipe or dry-pipe fire sprinkler system, and soil bearing pressure Material Strength: Concrete, masonry, steel and wood Foundation design based on Soils Report. Provide one (1) copy of the Soils/Geotechnical Report.
Building Sections. S5.1 Concrete Details
Building Sections. Preliminary wall sections.
Building Sections. Show vertical dimensions relating to floor, ceiling, and roof height. Note and indicate all materials and proposed listed assemblies for fire rated construction. F. Reflected Ceiling Plan Indicate ceiling materials. Show proposed ceiling layout. G. Enlarged Floor Plan(s) (as appropriate) Toilet Room Plans: Show plumbing fixtures, stall layout and handicap accessibility. Verify plumbing fixture count with code requirements. Kitchens: Show kitchen equipment layout. X. Xxxxxxxxx Develop outlines for doors, windows and associated frames. I. Structural Notes Live Loads: Floor, stairs, corridors, roof, snow, earthquake and wind. Dead Loads: Material weight, mechanical and electrical weight, wet-pipe or dry-pipe fire sprinkler system, and soil bearing pressure. Material Strength: Concrete, masonry, steel and wood. Foundation design based on Soils Report.
Building Sections. 4. Exterior elevations
Building Sections. Building Finish, Door and Window Schedules.
Building Sections. A7.1 Sections & Details A7.2 Sections & Details A7.3 Sections & Details A7.4 Sections & Details A7.5 Sections & Details A7.6 Sections & Details A8.1 Rated Assemblies
Building Sections. A7.1 Sections & Details A7.2 Sections& Details A7.3 Sections & Details A7.4 Sections & Details A7.5 Sections & Details A7.6 Sections & Details A8.1 Rated Assemblies A8.2 Rated Assemblies S001 General Notes, Schedules, Legend, & Load Tables S002 Notes, Schedules, and Special Inspection Notes S101 Foundation Plan S102 Second Floor Framing Plan S103 Third Floor Framing Plan S104 Attic Framing Plan S105 Roof Framing Plan S201 Foundation Sections S301 Floor Framing Sections S401 Roof Framing Sections S402 Typical Details S500 Frame Elevations