BUTANE SPECIFICATION Sample Clauses

BUTANE SPECIFICATION. The Butane export specification is set out hereunder. The CATS Parties retain the right at their discretion to vary the specifications from time to time provided that at all times the delivered Shipper Product will be of merchantable quality. In all cases the test methods shall be based on the most recently published standards. SPECIFICATION TEST METHOD VALUE WATER DEWPOINT Less than –30 at 1.013 Bara Free Water Content ASTM D-1835 none VAPOUR PRESSURE ASTM D-2598 483 kPa Gauge @ 37.8 deg. C (maximum) COMPOSITION ASTM D-2163 (liquid volume) NITROGEN 0.1 % (maximum) CARBON DIOXIDE 0.1 % (maximum) ETHANE 0.1 % (maximum) PROPANE 0.5 % (maximum) MIXED BUTANES 95.0 % (minimum) Pentane and heavier hydrocarbons 1.5 % (maximum) Total unsaturated hydrocarbons 1.0 % (maximum) (olefins) RESIDUAL MATTER: Maximum R Number ASTM D-2158 10 Maximum O Number ASTM D-2158 Pass CORROSION, COPPER STRIP Maximum ASTM D-1838 No. 1 H2S BS 4250 1 ppm (vol.) (maximum) MERCURY 10 ppb (wt) (maximum) TOTAL SULPHUR ASTM D-2784 50 ppm (wt) (maximum) REDELIVERY PRESSURE a maximum of 10.5 xxxx REDELIVERY TEMPERATURE 33oC maximum
AutoNDA by SimpleDocs

Related to BUTANE SPECIFICATION

  • Technical Specification As enumerated in Special Conditions of Contract/Scope of Work/attached Drawing/ Details/Schedule of Rates.

  • DAF Specifications Developer shall submit initial specifications for the DAF, including System Protection Facilities, to Connecting Transmission Owner and NYISO at least one hundred eighty (180) Calendar Days prior to the Initial Synchronization Date; and final specifications for review and comment at least ninety (90) Calendar Days prior to the Initial Synchronization Date. Connecting Transmission Owner and NYISO shall review such specifications to ensure that the DAF are compatible with the technical specifications, operational control, and safety requirements of the Connecting Transmission Owner and NYISO and comment on such specifications within thirty (30) Calendar Days of Developer’s submission. All specifications provided hereunder shall be deemed to be Confidential Information.

  • Service Specification The Parties have agreed upon the scope and specification of the Services provided under this Service Agreement in the Service Specification.

  • Equipment Specifications All equipment must meet the contract specifications and all federal and State safety codes and regulations in effect at the date of manufacture. All equipment must be Original Equipment Manufacturer (OEM) equipment unless otherwise stated in the contract. Items Offered as New. All products, materials, supplies, replacement parts, and equipment offered and furnished must be new, of current manufacturer production, and must have been formally announced by the manufacturer as being commercially available, unless otherwise stated in this Contract.

  • Technical Specifications The Technical Specifications furnished on the CD are intended to establish the standards for quality, performance and technical requirements for all labor, workmanship, material, methods and equipment necessary to complete the Work. When specifications and drawings are provided or referenced by the County, these are to be considered part of the Scope of Work, and to be specifically documented in the Detailed Scope of Work. For convenience, the County supplied specifications, if any, and the Technical Specifications furnished on the CD.

  • The Specifications The Specifications are that portion of the Contract Documents consisting of the written requirements for materials, equipment, systems, standards and workmanship for the Work, and performance of related services.

  • EODUF Packing Specifications 7.3.1 The data will be packed using ATIS EMI records. A pack will contain a minimum of one (1) message record or a maximum of ninety-nine thousand nine hundred and ninety-nine (99,999) message records plus a pack header record and a pack trailer record. One transmission can contain a maximum of ninety-nine (99) packs and a minimum of one (1) pack.

  • Escrow Format Specification 3.1. Deposit’s Format. Registry objects, such as domains, contacts, name servers, registrars, etc. will be compiled into a file constructed as described in draft-xxxxx-xxxxxxx-registry-data-escrow, see Part A, Section 9, reference 1 of this Specification and draft-xxxxx-xxxxxxx-dnrd-objects-mapping, see Part A, Section 9, reference 2 of this Specification (collectively, the “DNDE Specification”). The DNDE Specification describes some elements as optional; Registry Operator will include those elements in the Deposits if they are available. If not already an RFC, Registry Operator will use the most recent draft version of the DNDE Specification available at the Effective Date. Registry Operator may at its election use newer versions of the DNDE Specification after the Effective Date. Once the DNDE Specification is published as an RFC, Registry Operator will implement that version of the DNDE Specification, no later than one hundred eighty (180) calendar days after. UTF-8 character encoding will be used.

  • Product Specifications The Company agrees that all Products sold to Xxxx hereunder shall conform to the respective specifications set forth on Schedule A or to such other specifications as are from time to time agreed upon by the Parties.

  • Packing Specifications 7.3.1 A pack will contain a minimum of one message record or a maximum of 99,999 message records plus a pack header record and a pack trailer record. One transmission can contain a maximum of 99 packs and a minimum of one pack.

Time is Money Join Law Insider Premium to draft better contracts faster.