MAINTENANCE OF THE SAID BUILDING / APARTMENT / PROJECT The Promoter shall be responsible to provide and maintain essential services in the Project till the taking over of the maintenance of the project by the association of the allottees. The cost of such maintenance has been included in the Total Price of the [Apartment/Plot].
Commercial Driver’s License As a result of recent Federal statutory requirements, the State of Michigan enacted Act 346 of 1988. The parties agree that as a result of these statutory requirements some employees within the Technical Bargaining Unit may be required to obtain and retain a Commercial Drivers License (CDL) to continue to perform certain duties for the State. Whenever a CDL is referred to in this Section, it is understood to mean the CDL and any required endorsements. In order to implement this provision, the parties agree to the following: A. The Employer will reimburse the cost of obtaining and renewing the required CDL group license and endorsements for those employees in positions where such license and endorsements are required. B. The Employer will reimburse, on a one time basis, the fee for the skills test, if required, provided the skills test is not being required because of the employee's poor driving record. In that case, the employee is responsible for the cost of the skills test. Where a skills test is required, the employee will be permitted to utilize the appropriate state vehicle. C. Employees shall be eligible for one grant of administrative leave to take the test to obtain or renew the CDL. Should the employee fail the test initially, the employee shall complete the necessary requirements on non-work time. D. Employees reassigned to a position requiring a CDL shall be eligible for reimbursement and administrative leave in accordance with paragraphs 1, 2, and 3 of this Section. E. Employees desiring to transfer, promote, bump or be recalled to a position requiring a CDL are not eligible for reimbursement for obtaining the initial CDL but shall be eligible for reimbursement for renewals. F. Employees who fail to obtain, or retain, a CDL may be subject to removal from their positions. Employees who fail required tests may seek a 90 day extension of their current license, during which the Employer will retain the employee in his or her current or equivalent position. The Employer shall not be responsible for any fees associated with such extensions. At the end of the 90 day extension, if the employee fails to pass all required tests, the employee may be reassigned at the Employer's discretion, in accordance with applicable contractual provisions, to an available position not requiring a CDL for which the employee is qualified, or, if no position is available the employee will be laid off without bumping rights and will be placed on the Departmental Recall List, subject to recall in accordance with this Agreement. Those employees not choosing to extend their license for the 90 day period will be removed from their positions at the expiration of their current license and may be reassigned at the Employer's discretion, in accordance with applicable contractual provisions, to an available position not requiring a CDL for which the employee qualifies, or if no position is available, he or she will be laid off without bumping rights and will be placed on the Departmental Recall list. G. Employees required to obtain a medical certification of fitness shall have the "Examination to Determine Physical Condition of Drivers" form filed in their medical file. A copy of the medical "Examiners Certificate" shall be placed in their personnel file. The Employer agrees to pay for the examination and to grant administrative leave for the time necessary to complete the examination. The fitness standards for a CDL are unchanged from current Federal Department of Transportation Standards and Michigan Motor Carrier Standards. H. Employees who do not meet the required physical standards but who are otherwise qualified for a CDL may apply for a waiver to the Motor Carrier Appeal Board. I. Those employees employed by the State as intra-state drivers prior to June 10, 1984 shall be grandparented into the process and thereby be exempt from the medical certification requirement.
School Improvement The parties do hereby mutually agree that the school improvement process currently in effect will continue. Any plan developed by the committees shall not be in conflict with the master agreement or board policy.
Phase II A small portion of the work for the Phase II modifications to the Plattsburgh Substation will be performed by Transmission Owner, and the remainder will be performed by Clinton and ▇▇▇▇▇▇▇▇▇. A detailed definition of the specific scope for Transmission Owner and Clinton and ▇▇▇▇▇▇▇▇▇ including interface points shall be defined during the design phase and, as such documents become available, copies will be delivered to the NYISO, Transmission Owner, Noble Altona Windpark, LLC and Marble River, LLC. The full scope includes the installation of wave traps, CCVT’s and modifications and/or additions to relaying on the MWP-1 and MWP- 2 lines. These lines will be reconfigured at the completion of Phase II to connect to ▇▇▇▇▇ and ▇▇▇▇▇▇▇ Substations on MWP-1 and the ▇▇▇▇ Substation on MWP-2. Clinton and ▇▇▇▇▇▇▇▇▇ will design the upgrades and purchase the materials based on the outline specification that was prepared and issued by Transmission Owner. The work to be performed by Clinton and ▇▇▇▇▇▇▇▇▇ will include both the materials for the exterior and interior installations and items for Transmission Owner installation inside the control building in existing relay panels and communication racks. In addition, Clinton and ▇▇▇▇▇▇▇▇▇ will be responsible for the exterior and interior construction work and will provide construction management services in coordination with Transmission Owner. The civil design for the foundations and the electrical design for the cable runs to the control room will be designed by, as approved by Transmission Owner, and installed under the supervision and control of Clinton and ▇▇▇▇▇▇▇▇▇. The equipment will be selected and procured in accordance with the specifications developed during the detailed engineering phase, copies of which shall be furnished to the NYISO, Transmission Owner, Noble Altona Windpark, LLC and Marble River, LLC. The construction of the foundations, structures, wave traps, CCTV and cable runs into the control building to the termination cabinets will be completed by Clinton and ▇▇▇▇▇▇▇▇▇. The work at the Plattsburgh Substation will be installed under Transmission Owner’s CPP-1. Transmission Owner will provide Protection and Controls Engineering, install and terminate wiring from the termination cabinets to the control panels and relays, install relays and equipment in the existing panels, and will commission such work inside the 230kV control building. Transmission Owner will develop the communications protocols and data flow over the circuits.
Underground Facilities All underground pipelines, conduits, ducts, cables, wires, manholes, vaults, tanks, tunnels, or other such facilities or attachments, and any encasements containing such facilities, including without limitation those that convey electricity, gases, steam, liquid petroleum products, telephone or other communications, cable television, water, wastewater, storm water, other liquids or chemicals, or traffic or other control systems.