Connection Point Sample Clauses

Connection Point. Water to be supplied under this Agreement shall be made available at the Connection Point. Title to, and risk in, the water supplied shall pass to the Licensee on behalf of its Customer at the Connection Point.
AutoNDA by SimpleDocs
Connection Point. (a) Subject to the electricity legislation, we must provide, install and maintain equipment for the provision of customer connection services at the premises in a manner which is safe and in accordance with the electricity legislation. (b) Our obligations extend up to the supply point for the delivery of electricity from the supply network for the premises and not beyond.
Connection Point. The Customer must ensure that they take supply from the Connection Point at all times in accordance with the Specification. Where the Customer is an Embedded Generator, the Customer must not export electricity in excess of the export capacity in the Specification.
Connection Point. 3.1 KWSC hereby permits and authorizes the RDEK System to be connected to the KWSC System at the Connection Point under the terms and conditions contained in this Agreement. 3.2 Subject to the terms and conditions of this Agreement, KWSC will provide to the RDEK, at the Connection Point, for use solely within the SA, the following maximum amounts of potable water, which includes all connections requested by the RDEK and approved by the KWSC to November 1, 2022: a) Average Daily Demand: 387 cubic meters per day; b) Maximum Daily Demand: 956 cubic meters per day; c) Total Annual Average Demand: 141,255 cubic meters per year; d) Should the RDEK water consumption, as confirmed by the Meter, be less than the volume outlined in Section 3.2 b), then KWSC shall be obligated to provide 120% of the Maximum Daily Demand for the period April 1st to September 30th from the previous year, as confirmed by the Meter, plus an allowance for any new connection applications received by the RDEK from the time of the last Meter reading or 100% of those volumes outlined in Sections 3.2 a), b), and c), whichever is less. The allowance for each new connection application shall be based on the Maximum Daily Demand of the previous year divided by the total number of existing units within the SA. 3.3 KWSC acknowledges that amongst other purposes the RDEK will be relying upon the water supply provided for under this Agreement for fire protection purposes, in particular the extinguishment of fires within the SA and KWSC agrees to provide to the RDEK at the Connection Point a water flow sufficient to satisfy the Fire Flow requirements as determined by RDEK Subdivision Servicing Bylaw No. 1954 and the "Fire Underwriters Survey" as amended from time to time. 3.4 Without restricting or expanding the obligations set out in Sections 3.2 and 3.3, the Peak Flow of potable water that KWSC shall deliver to RDEK at the Connection Point, for use within the SA shall be: a) Peak Consumptive Flow: Maximum 32.7 litres per second at a normal working pressure of 380 kilopascals at the Connection Point; b) Peak Fire Flow: 90 litres per second for a duration of 111 minutes at a minimum pressure of 150 kilopascals at the Connection Point. 3.5 The potable water provided in accordance with Section 3.2 shall be of a quality which complies with the current edition of the Guidelines for Canadian Drinking Water Quality published by Health Canada, the BC Drinking Water Protection Act, and the BC Drinking Water Pr...
Connection Point. The location where the Offsite Facilities connect to the System as shown on the attached Exhibit C.
Connection Point. 3.1 KWSC hereby permits and authorizes the RDEK System to be connected to the KWSC System at the Connection Point under the terms and conditions contained in this Agreement. 3.2 Subject to the terms and conditions of this Agreement, KWSC will accept from the RDEK, at the Connection Point, sewage generated solely within the SA, of the following amounts of domestic sewage: a) Average Flow: 175 cubic meters per day; b) Total Annual Volume: 63,350 cubic meters per year; c) In reference to sections 3.2 a) and b), should the RDEK sewage volumes as confirmed at the Meter be less than the volume shown in Sections 3.2 a), then KWSC shall be obligated to have the capacity to accept 120% of the Average Flow as confirmed at the Meter for the period April 1st to September 30th from the previous year plus allowance for any new connection applications received by the RDEK from the time of the last Meter reading, or 100% of those volumes as in Sections 3.2 a) and b), whichever is less; d) The allowance for each new connection application shall be based on the Average Flow of the immediately preceding year divided by the total number of existing units within the SA. 3.3 The domestic sewage accepted at the Connection Point and generated within the SA must meet the standards and requirements adopted and amended by KWSC from time to time, and any applicable federal, provincial and local government laws, regulations, Codes and standards, and must be normal strength sewage received from residential use and occupancy and having a BOD not exceeding 200 milligrams per litre and TSS not exceeding 200 milligrams per litre. 3.4 The Parties acknowledge and agree that there may be reasonable concerns which may arise from time to time regarding the flows/volumes of sewage and sewage characteristics received at the Connection Point. The Parties agree to use a collaborative approach to addressing any reasonable bone fide concerns raised in this regard. 3.5 The Parties acknowledge and agree that there may be reasonable concerns which may arise from time to time as to whether the sewage disposal capacity is adequate or sufficient to meet the sewage service requirements of the SA. The Parties agree to use a collaborative approach to addressing any reasonable bone fide concerns raised in this regard. Nevertheless, the Parties acknowledge that the sewage disposal regime outlined in Section 3.2 anticipates providing sewage disposal to: a) 285 single family SA Residences;* b) 151 two-family or m...
Connection Point. The geographic location where the corporate limits of Cary and Apex meet on NC Highway 55 where the Parties will join their respective Components to create the direct fiberoptic connection between the Parties.
AutoNDA by SimpleDocs
Connection Point. 1. The Connection Point shall be the flange bottom or top of export pipe weld at the downstream gate valve of the gas transfer and metering device at the plant . 2. The moment the Supplier transfers the gas to the User at the Connection Point, according to the arrangements in this Agreement, ownership and custody rights, loss, risks and any related matters regarding the gas provided shall by solely borne by the User. 3. After the transfer of rights of the gas, any transfer of gas made by the User and its consequences will have nothing to do with the Supplier. 4. In relation to the metering device installed at the User’s station, if the User deliberately damages the metering device leading to its inability to conduct measurements or behavior of theft of gas, after the Supplier discovers this, the Supplier will have the right to stop supplying gas to the User and decide who to hold responsible.
Connection Point. The Generation Facility will be connected ….
Connection Point. (clause 1.1): The line side cable termination in the point of attachment. Cable termination inside the service pit. The line side terminals of the Connection Point.