Design Description Sample Clauses
Design Description. Typical floor toilet rooms are provided with 2” x 2” ceramic tile floors and full height ceramic tile walls on wet walls only, painted gypsum drywall ceilings, cove lighting at mirrors and toilets. Base building toilet rooms for the New Tower Building to comply with all requirements of the Americans with Disabilities Act. Tenant, at tenant’s cost and expense, shall be permitted to connect any private toilets into the Building’s toilet exhaust system, assuming the same are within code and capacity of the Building’s toilet exhaust system.
Design Description. Clear length of 30.0 m, inside breadth of 2.2.m and a inside depth of 2.9 m is required. The design of the gangway is to be carried out considering a load of 600 kg / Cm2. 20% additional load has to be considered for barge movement in floating condition. IS 800 has to be followed for gangway design. The force in each member has to be worked out to retain the combined stress ratio less than unity. Ordinary angle shave to be adopted for wind bracing. One set of adequate size of rollers are to be provided on the pontoon end. The gangway has to be fixed on yoke and yoke base. Adequate safety factor has to be consider to sustain marine environment.
Design Description. Typical floor toilet rooms are provided with 2” x 2” ceramic tile floors and full height ceramic tile walls on wet walls only, painted gypsum drywall ceilings, cove lighting at mirrors and toilets. Base Building toilet rooms to comply with all requirements of the Americans with Disabilities Act.
Design Description. The conceptual design has been made the part of the tender documents. Minimum size of Bus Shelter is 9.30 m x 2.20 m and maximum size is 9.30 m x 3.00
Design Description. SUMMARY This Product Specification is for a calcium alginate wound dressing incorporating Acticoat technology for antimicrobial performance. The product is intended for dressing moderately to highly exudative wounds such as decubitus ulcers, diabetic ulcers and venous stasis ulcers. The product in the form of a ribbon would also be suitable for packing deep cavity wounds. Two product sizes will be produced: 4” x 5” and a 0.75” x 12” ribbon.
Design Description. For walkway a clear length of 100.0 m and a breadth of 3.m is required, whereas for the gangways, a clear length of 8 m and breadth of 3 m for each gangway is required. The design of the walkway & gangways are to be carried out considering a load of 600 kg / Cm2. 20% additional load has to be considered for barge movement in floating condition. IS 800 has to be followed for design. The force in each member has to be worked out to retain the combined stress ratio less than unity. Ordinary angle shave to be adopted for wind bracing. Set of adequate size of rollers are to be provided on the connection between pontoons to gangways and between gangways to walkway. The walkway has to be fixed on yoke and yoke base. Adequate safety factor has to be considered to sustain marine environment.
Design Description. Clear length of 30.0 m, inside breadth of 2.2 m and an inside depth of 2.9 m is required for the Gangway. The design of the Gangway is to be carried out considering a load of 600 kg / Cm2. 20% additional load has to be considered for barge movement in floating condition. IS: 800 has to be followed for design. The force in each member has to be worked out to retain the combined stress ratio less than unity. Ordinary angle shave to be adopted for wind bracing. The Gangway has to be fixed on appropriate foundation on the Bank and with Roller arrangement on Pontoon side. Set of adequate size of rollers are to be provided on the connection between pontoon and gangway. Adequate safety factor has to be considered to sustain the marine environment.