Interconnection Customer Payments Not Taxable The Parties intend that all payments or property transfers made by the Interconnection Customer to the Participating TO for the installation of the Participating TO's Interconnection Facilities and the Network Upgrades shall be non-taxable, either as contributions to capital, or as a refundable advance, in accordance with the Internal Revenue Code and any applicable state income tax laws and shall not be taxable as contributions in aid of construction or otherwise under the Internal Revenue Code and any applicable state income tax laws.
Interconnection Customer Compensation If the CAISO requests or directs the Interconnection Customer to provide a service pursuant to Articles 9.6.3 (Payment for Reactive Power) or 13.5.1 of this LGIA, the CAISO shall compensate the Interconnection Customer in accordance with the CAISO Tariff.
Interconnection Customer Drawings Within one hundred twenty (120) days after the date of Initial Operation, unless the Interconnection Parties agree on another mutually acceptable deadline, the Interconnection Customer shall deliver to the Transmission Provider and the Interconnected Transmission Owner final, “as-built” drawings, information and documents regarding the Customer Interconnection Facilities, including, as and to the extent applicable: a one-line diagram, a site plan showing the Customer Facility and the Customer Interconnection Facilities, plan and elevation drawings showing the layout of the Customer Interconnection Facilities, a relay functional diagram, relaying AC and DC schematic wiring diagrams and relay settings for all facilities associated with the Interconnection Customer's step-up transformers, the facilities connecting the Customer Facility to the step-up transformers and the Customer Interconnection Facilities, and the impedances (determined by factory tests) for the associated step-up transformers and the Customer Facility. As applicable, the Interconnection Customer shall provide Transmission Provider and the Interconnected Transmission Owner specifications for the excitation system, automatic voltage regulator, Customer Facility control and protection settings, transformer tap settings, and communications.
Interconnection Customer (1) Interconnection Customer shall construct and, unless otherwise indicated, shall own, the following Interconnection Facilities: None (2) In the event that, in accordance with the Interconnection Construction Service Agreement, Interconnection Customer has exercised the Option to Build, it is hereby permitted to build in accordance with and subject to the conditions and limitations set forth in that Section, the following portions of the Transmission Owner Interconnection Facilities which constitute or are part of the Customer Facility: None Ownership of the facilities built by Interconnection Customer pursuant to the Option to Build shall be as provided in the Interconnection Construction Service Agreement.
Interconnection Customer Authority Consistent with Good Utility Practice, this LGIA, and the CAISO Tariff, the Interconnection Customer may take actions or inactions with regard to the Large Generating Facility or the Interconnection Customer’s Interconnection Facilities during an Emergency Condition in order to (i) preserve public health and safety, (ii) preserve the reliability of the Large Generating Facility or the Interconnection Customer’s Interconnection Facilities,
Interconnection Customer Provided Services The services provided by Interconnection Customer under this LGIA are set forth in Article 9.6 and Article 13.5. 1. Interconnection Customer shall be paid for such services in accordance with Article 11.6.
Contracted Services PPG and Member Physicians shall render Contracted Services which are not PPG Capitated Services to Members covered under this Addendum B and shall be compensated on a fee-for-service basis at the rates set forth in Addendum E. PPG shall submit claims in accordance with the terms of this Agreement and State and federal law.
Service Area (a) SORACOM shall provide the SORACOM Air Global Service within the area designated on the web site of SORACOM (the “Service Area”), provided, that, the Service Area may be different if stated otherwise as specified by SORACOM separately. However, within the Service Area, you may not use the SORACOM Air Global Service in places where transmissions are difficult to send or receive. (b) The parties of this Agreement acknowledge that there may be countries or locations within which SORACOM may be restricted from providing the SORACOM Air Global Service due to applicable laws, regulations, decisions, rules or orders (“Restrictions”). During the Term, SORACOM will use reasonable efforts to monitor whether there are any such Restrictions. SORACOM may in its sole discretion and at any time, suspend, discontinue, limit, or modify the SORACOM Air Global Service or impose additional requirements on the provision of the SORACOM Air Global Service, as may be reasonably required to comply with any such Restrictions. (c) In no event will SORACOM be required to provide the SORACOM Air Global Service in countries or locations, or in a manner that would be in violation of the Restrictions and its failure to provide the SORACOM Air Global Service due to the Restrictions will not be deemed to be a breach of its obligations under this Agreement. (d) In the event that any Restriction, or any change in applicable law, regulation, decision, rule or order materially or adversely affects the delivery of the SORACOM Air Global Service (including the economic viability thereof), SORACOM will notify Subscribers in writing and the parties will negotiate in good faith regarding changes to this Agreement. If the parties cannot reach agreement within 30 days after notification from SORACOM requesting renegotiation, SORACOM may terminate the Agreement upon 30 days’ written notice to the Subscriber.
Reactive Power and Primary Frequency Response 9.6.1 Power Factor Design Criteria
Shift Rotation Routine shift rotation is not an approach to staffing endorsed by the Employer. Except for emergency situations where it may be necessary to provide safe patient care, shift rotation will not be utilized without mutual consent. If such an occasion should ever occur, volunteers will be sought first. If no one volunteers, the Employer will rotate shifts on an inverse seniority basis until the staff vacancies are filled.