Gatherer’s Obligations and Rights. Gatherer shall endeavor to maintain the pressure at the Receipt Points at a pressure not to exceed 1.3 times the Design Suction Pressure maintained at Gatherer’s compressor facilities for a given System. Gatherer will not raise the Actual Suction Pressure on a System by more than 30% above the Design Suction Pressures set forth in Exhibit 1.43 without Shipper Supermajority Approval. If the Anchor Shippers, upon Shipper Supermajority Approval, request that Gatherer lower the Design Suction Pressure on such System, then Gatherer must provide such lower pressures and all associated costs will be included in the COS Calculations and recovered through the adjustment to the Gathering Fee and Compression Fee applied to the adjusted Deemed Compression Stages. Any change in Design Suction Pressure must be requested in the increments set forth in the third column of the table in Section 4.5.1. Gatherer may install, operate and maintain, at its sole expense, such pressure-regulating devices as may be necessary to regulate the pressure of Gas at the Receipt Points.
Appears in 4 contracts
Samples: Gas Gathering Agreement (Epsilon Energy Ltd.), Gas Gathering Agreement (Epsilon Energy Ltd.), Gas Gathering Agreement (Epsilon Energy Ltd.)