We use cookies on our site to analyze traffic, enhance your experience, and provide you with tailored content.
For more information visit our privacy policy.Project Administration The Contractor shall provide project administration for all Subcontractors, vendors, suppliers, and others involved in implementing the Work and shall coordinate administration efforts with those of the A/E and ODR in accordance with these Uniform General and Supplementary Conditions and provisions of Division 1 Specifications, and as outlined in the Pre- construction Conference.
DTC DIRECT REGISTRATION SYSTEM AND PROFILE MODIFICATION SYSTEM (a) Notwithstanding the provisions of Section 2.04, the parties acknowledge that the Direct Registration System (“DRS”) and Profile Modification System (“Profile”) shall apply to uncertificated American Depositary Shares upon acceptance thereof to DRS by DTC. DRS is the system administered by DTC pursuant to which the Depositary may register the ownership of uncertificated American Depositary Shares, which ownership shall be evidenced by periodic statements issued by the Depositary to the Owners entitled thereto. Profile is a required feature of DRS which allows a DTC participant, claiming to act on behalf of an Owner of American Depositary Shares, to direct the Depositary to register a transfer of those American Depositary Shares to DTC or its nominee and to deliver those American Depositary Shares to the DTC account of that DTC participant without receipt by the Depositary of prior authorization from the Owner to register such transfer. (b) In connection with and in accordance with the arrangements and procedures relating to DRS/Profile, the parties understand that the Depositary will not verify, determine or otherwise ascertain that the DTC participant which is claiming to be acting on behalf of an Owner in requesting a registration of transfer and delivery as described in subsection (a) has the actual authority to act on behalf of the Owner (notwithstanding any requirements under the Uniform Commercial Code). For the avoidance of doubt, the provisions of Sections 5.03 and 5.08 shall apply to the matters arising from the use of the DRS. The parties agree that the Depositary’s reliance on and compliance with instructions received by the Depositary through the DRS/Profile System and in accordance with this Deposit Agreement shall not constitute negligence or bad faith on the part of the Depositary.
Registry Services “Registry Services” are, for purposes of the Agreement, defined as the following: (a) those services that are operations of the registry critical to the following tasks: the receipt of data from registrars concerning registrations of domain names and name servers; provision to registrars of status information relating to the zone servers for the TLD; dissemination of TLD zone files; operation of the registry DNS servers; and dissemination of contact and other information concerning domain name server registrations in the TLD as required by this Agreement; (b) other products or services that the Registry Operator is required to provide because of the establishment of a Consensus Policy as defined in Specification 1; (c) any other products or services that only a registry operator is capable of providing, by reason of its designation as the registry operator; and (d) material changes to any Registry Service within the scope of (a), (b) or (c) above.
Project Administration Designation Pursuant to Paragraph (B) of Rule 164-1-21 of the Administrative Code, the Recipient shall designate its Chief Executive Officer, Chief Fiscal Officer and Project Manager in Appendix B of this Agreement. Changes in these designations must be made in writing.
STATEWIDE CONTRACT MANAGEMENT SYSTEM If the maximum amount payable to Contractor under this Contract is $100,000 or greater, either on the Effective Date or at any time thereafter, this section shall apply. Contractor agrees to be governed by and comply with the provisions of §§00-000-000, 00-000-000, 00-000-000, and 00- 000-000, C.R.S. regarding the monitoring of vendor performance and the reporting of contract information in the State’s contract management system (“Contract Management System” or “CMS”). Contractor’s performance shall be subject to evaluation and review in accordance with the terms and conditions of this Contract, Colorado statutes governing CMS, and State Fiscal Rules and State Controller policies.
FORMAT AND CONTENT FOR REGISTRY OPERATOR MONTHLY REPORTING Registry Operator shall provide one set of monthly reports per gTLD, using the API described in draft-‐xxxxxx-‐icann-‐registry-‐interfaces, see Specification 2, Part A, Section 9, reference 5, with the following content. ICANN may request in the future that the reports be delivered by other means and using other formats. ICANN will use reasonable commercial efforts to preserve the confidentiality of the information reported until three (3) months after the end of the month to which the reports relate. Unless set forth in this Specification 3, any reference to a specific time refers to Coordinated Universal Time (UTC). Monthly reports shall consist of data that reflects the state of the registry at the end of the month (UTC).
Information Systems Acquisition Development and Maintenance a. Client Data – Client Data will only be used by State Street for the purposes specified in this Agreement.
Pricing for Registry Services (a) With respect to initial domain name registrations, Registry Operator shall provide ICANN and each ICANN accredited registrar that has executed the registry-‐registrar agreement for the TLD advance written notice of any price increase (including as a result of the elimination of any refunds, rebates, discounts, product tying or other programs which had the effect of reducing the price charged to registrars, unless such refunds, rebates, discounts, product tying or other programs are of a limited duration that is clearly and conspicuously disclosed to the registrar when offered) of no less than thirty (30) calendar days. Registry Operator shall offer registrars the option to obtain initial domain name registrations for periods of one (1) to ten (10) years at the discretion of the registrar, but no greater than ten (10) years. (b) With respect to renewal of domain name registrations, Registry Operator shall provide ICANN and each ICANN accredited registrar that has executed the registry-‐registrar agreement for the TLD advance written notice of any price increase (including as a result of the elimination of any refunds, rebates, discounts, product tying, Qualified Marketing Programs or other programs which had the effect of reducing the price charged to registrars) of no less than one hundred eighty (180) calendar days. Notwithstanding the foregoing sentence, with respect to renewal of domain name registrations: (i) Registry Operator need only provide thirty (30) calendar days notice of any price increase if the resulting price is less than or equal to (A) for the period beginning on the Effective Date and ending twelve (12) months following the Effective Date, the initial price charged for registrations in the TLD, or (B) for subsequent periods, a price for which Registry Operator provided a notice pursuant to the first sentence of this Section 2.10(b) within the twelve (12) month period preceding the effective date of the proposed price increase; and (ii) Registry Operator need not provide notice of any price increase for the imposition of the Variable Registry-‐Level Fee set forth in Section 6.3. Registry Operator shall offer registrars the option to obtain domain name registration renewals at the current price (i.e., the price in place prior to any noticed increase) for periods of one (1) to ten (10) years at the discretion of the registrar, but no greater than ten (10) years. (c) In addition, Registry Operator must have uniform pricing for renewals of domain name registrations (“Renewal Pricing”). For the purposes of determining Renewal Pricing, the price for each domain registration renewal must be identical to the price of all other domain name registration renewals in place at the time of such renewal, and such price must take into account universal application of any refunds, rebates, discounts, product tying or other programs in place at the time of renewal. The foregoing requirements of this Section 2.10(c) shall not apply for (i) purposes of determining Renewal Pricing if the registrar has provided Registry Operator with documentation that demonstrates that the applicable registrant expressly agreed in its registration agreement with registrar to higher Renewal Pricing at the time of the initial registration of the domain name following clear and conspicuous disclosure of such Renewal Pricing to such registrant, and (ii) discounted Renewal Pricing pursuant to a Qualified Marketing Program (as defined below). The parties acknowledge that the purpose of this Section 2.10(c) is to prohibit abusive and/or discriminatory Renewal Pricing practices imposed by Registry Operator without the written consent of the applicable registrant at the time of the initial registration of the domain and this Section 2.10(c) will be interpreted broadly to prohibit such practices. For purposes of this Section 2.10(c), a “Qualified Marketing Program” is a marketing program pursuant to which Registry Operator offers discounted Renewal Pricing, provided that each of the following criteria is satisfied: (i) the program and related discounts are offered for a period of time not to exceed one hundred eighty (180) calendar days (with consecutive substantially similar programs aggregated for purposes of determining the number of calendar days of the program), (ii) all ICANN accredited registrars are provided the same opportunity to qualify for such discounted Renewal Pricing; and (iii) the intent or effect of the program is not to exclude any particular class(es) of registrations (e.g., registrations held by large corporations) or increase the renewal price of any particular class(es) of registrations. Nothing in this Section 2.10(c) shall limit Registry Operator’s obligations pursuant to Section 2.10(b). (d) Registry Operator shall provide public query-‐based DNS lookup service for the TLD (that is, operate the Registry TLD zone servers) at its sole expense.
Quality Management System Supplier hereby undertakes, warrants and confirms, and will ensue same for its subcontractors, to remain certified in accordance with ISO 9001 standard or equivalent. At any time during the term of this Agreement, the Supplier shall, if so instructed by ISR, provide evidence of such certifications. In any event, Supplier must notify ISR, in writing, in the event said certification is suspended and/or canceled and/or not continued.
Primary Frequency Response Developer shall ensure the primary frequency response capability of its Large Generating Facility by installing, maintaining, and operating a functioning governor or equivalent controls. The term “functioning governor or equivalent controls” as used herein shall mean the required hardware and/or software that provides frequency responsive real power control with the ability to sense changes in system frequency and autonomously adjust the Large Generating Facility’s real power output in accordance with the droop and deadband parameters and in the direction needed to correct frequency deviations. Developer is required to install a governor or equivalent controls with the capability of operating: (1) with a maximum 5 percent droop ± 0.036 Hz deadband; or (2) in accordance with the relevant droop, deadband, and timely and sustained response settings from an approved Applicable Reliability Standard providing for equivalent or more stringent parameters. The droop characteristic shall be: (1) based on the nameplate capacity of the Large Generating Facility, and shall be linear in the range of frequencies between 59 and 61 Hz that are outside of the deadband parameter; or (2) based on an approved Applicable Reliability Standard providing for an equivalent or more stringent parameter. The deadband parameter shall be: the range of frequencies above and below nominal (60 Hz) in which the governor or equivalent controls is not expected to adjust the Large Generating Facility’s real power output in response to frequency deviations. The deadband shall be implemented: (1) without a step to the droop curve, that is, once the frequency deviation exceeds the deadband parameter, the expected change in the Large Generating Facility’s real power output in response to frequency deviations shall start from zero and then increase (for under-frequency deviations) or decrease (for over-frequency deviations) linearly in proportion to the magnitude of the frequency deviation; or (2) in accordance with an approved Applicable Reliability Standard providing for an equivalent or more stringent parameter. Developer shall notify NYISO that the primary frequency response capability of the Large Generating Facility has been tested and confirmed during commissioning. Once Developer has synchronized the Large Generating Facility with the New York State Transmission System, Developer shall operate the Large Generating Facility consistent with the provisions specified in Articles 9.5.5.1 and 9.5.5.2 of this Agreement. The primary frequency response requirements contained herein shall apply to both synchronous and non-synchronous Large Generating Facilities.