GPA Standard 2261. All samples shall be analyzed by Project Co to determine the molar fraction of the hydrocarbon and other components in the sample by gas chromatography using a mutually agreed method in accordance with GPA Standard 2261 - Method of Analysis for Gas and Similar Gaseous Mixtures by Gas Chromatography, current as of January 1st, 1990 and as periodically updated or as otherwise mutually agreed by the Parties. If better standards for analysis are subsequently adopted by GPA or other recognized competent impartial authority, upon mutual agreement of the Transporter and Project Co, they shall be substituted for the standard then in use, but such substitution shall not take place retroactively. A calibration of the chromatograph or other analytical instrument used shall be performed by Project Co immediately prior to the analysis of the sample of LNG delivered. Project Co shall give advance notice to the Transporter of the time Project Co intends to conduct a calibration thereof, and the Transporter shall have the right to have a representative present at each such calibration; provided, however, Project Co will not be obligated to defer or reschedule any calibration in order to permit the representative of the Transporter to be present.
Appears in 5 contracts
Samples: Shipping Services Agreement (Cheniere Corpus Christi Holdings, LLC), Shipping Services Agreement (Cheniere Corpus Christi Holdings, LLC), Shipping Services Agreement (Cheniere Corpus Christi Holdings, LLC)
GPA Standard 2261. All samples shall be analyzed by Project Co to determine the molar fraction of the hydrocarbon and other components in the sample by gas chromatography using a mutually agreed method in accordance with GPA Standard 2261 - 2261βMethod of Analysis for Gas and Similar Gaseous Mixtures by Gas Chromatography, current as of January 1st, 1990 and as periodically updated or as otherwise mutually agreed by the Parties. If better standards for analysis are subsequently adopted by GPA or other recognized competent impartial authority, upon mutual agreement of the Transporter and Project Co, they shall be substituted for the standard then in use, but such substitution shall not take place retroactively. A calibration of the chromatograph or other analytical instrument used shall be performed by Project Co immediately prior to the analysis of the sample of LNG delivered. Project Co shall give advance notice to the Transporter of the time Project Co intends to conduct a calibration thereof, and the Transporter shall have the right to have a representative present at each such calibration; provided, however, Project Co will not be obligated to defer or reschedule any calibration in order to permit the representative of the Transporter to be present.
Appears in 1 contract
Samples: Shipping Services Agreement (Cheniere Corpus Christi Holdings, LLC)