Maintenance Manual Sample Clauses

Maintenance Manual. No later than 60 (sixty) days prior to the Project Completion Date, the Contractor shall, in consultation with the Authority’s Engineer, evolve a maintenance manual (the “Maintenance Manual”) for the regular and preventive maintenance of the Project Highway in conformity with the Specifications and Standards, safety requirements and Good Industry Practice, and shall provide 5 (five) copies thereof to the Authority’s Engineer. The Authority’s Engineer shall review the Maintenance Manual within 15 (fifteen) days of its receipt and communicate its comments to the Contractor for necessary modifications, if any.
AutoNDA by SimpleDocs
Maintenance Manual. 17.3.1 No later than [180 (one hundred and eighty)] days prior to the Scheduled Completion Date, the Concessionaire shall, in consultation with the Independent Engineer, evolve a repair, operation and maintenance manual (the “Maintenance Manual”) for the regular and preventive maintenance of the Bus Terminal in conformity with the Specifications and Standards, Maintenance Requirements, Safety Requirements and Good Industry Practice, and shall provide 5 (five) copies thereof to the Authority and 2 (two) copies to the Independent Engineer. The Maintenance Manual shall be revised and updated once every 3 (three) years and the provisions of this Clause 17.3 shall apply, mutatis mutandis, to such revision. 17.3.2 Without prejudice to the provision of Clause 17.3.1, the Maintenance Manual shall, in particular, include provisions for maintenance of Project Assets and shall provide for life cycle maintenance, routine maintenance and reactive maintenance which may be reasonably necessary for maintenance and repair of the Project Assets, including replacement thereof, such that its overall condition conforms to Good Industry Practice.
Maintenance Manual. 17.3.1 No later than 90 (ninety) days prior to the Scheduled Completion Date, the Concessionaire shall, in consultation with the Independent Engineer, evolve a repair and maintenance manual (the “Maintenance Manual”) for the regular and preventive maintenance of the Project in conformity with the Specifications and Standards, Maintenance Requirements, Safety Requirements and Good Industry Practice, and shall provide 5 (five) copies thereof to the Authority and 2 (two) copies to the Independent Engineer. The Maintenance Manual shall be revised and updated once every 3 (three) years and the provisions of this Clause 17.3 shall apply mutatis mutandis, to such revision. 17.3.2 Without prejudice to the provision of Clause 17.3.1, the Maintenance Manual shall, in particular, include provisions for maintenance of Project Assets and shall provide for life cycle maintenance, routine maintenance and reactive maintenance which may be reasonably necessary for maintenance and repair of the Project/Assets, including replacement thereof, such that their overall condition conforms to Good Industry Practice.
Maintenance Manual. 7.3.1 Without prejudice to the other obligations of the Facility Manager, the Facility Manager agrees and acknowledges that it shall be required to undertake the SFM Project, in accordance with certain pre-identified work schedules. 7.3.2 Towards the aforesaid, the Facility Manager shall within 30 days from the Effective Date (and thereafter, on or prior to the 30 days before the commencement of each succeeding Financial Year therefrom), prepare, and submit for the approval of Authority, a repair, operation and maintenance manual (the “Maintenance Manual”), for all aspects of the SFM Project (including the operation, maintenance and repair of the Station Assets and Station Project Utilities). The Maintenance Manual shall be consistent with the requirements of Schedule 2 (Scope of SFM Project) and Schedule 3 (Station Service Level Standards), unless a waiver or relaxation is sought and granted by Authority in accordance with Article 7.2.1 above (whereupon such requirements shall be appropriately deemed to be modified for the relevant approved period). Such Maintenance Manual shall inter alia, provide for the following: (i) The mode and manner of carrying out of the SFM Project, including specifically the proposed measures of the Facility Manager for ensuring compliance requirements of Schedule 2 (Scope of SFM Project) and Schedule 3 (Station Service Level Standards); (ii) The manner of scheduling and deployment of manpower and resources; (iii) Arrangements and procedures for carrying out urgent repairs; (iv) Criteria and process to be adopted for deciding maintenance needs; (v) A cleaning schedule, for cleaning of : (a) toilets, platform area, washable apron, other track within the platform area (as shown on attached plan), sewer lines, circulating areas, water fountains and booths, water storage tanks, concourse, foot over-bridges and other passenger areas; (b) operational areas in the Station Area; (c) parking and other public areas; (d) walls (interior and facade) and signages; (e) Station Project Utilities and equipment (in public and operational areas) at the Station; (f) Other areas in the Station Area; (vi) Painting schedule for painting, colour washing, distemper, polishing, and other allied activities for the Station Area; (vii) Schedule for undertaking Pest and rodent control for the Maintenance Area; (viii) Maintenance schedule for maintenance of Station Project Utilities and Station Assets, in accordance with Good Industry Practices and in compl...
Maintenance Manual. 17.3.1 No later than 180 (one hundred and eighty) days prior to the Scheduled Completion Date, the Concessionaire shall, in consultation with the Independent Engineer, evolve a repair, operation and maintenance manual (the "Maintenance Manual") for the regular and preventive maintenance of the Bus Terminal in conformity with the Specifications and Standards, Maintenance Requirements, Safety Requirements and Good Industry Practice, and shall provide 5 (five) copies thereof to the Authority and 2 (two) copies to the Independent Engineer. After the completion of tenure of Independent Engineer in terms of its engagement, the Maintenance Committee shall take decisions related to any revision or updation required in the Maintenance Manual and the provisions of this Clause 17.3 shall apply, mutatis mutandis, to such revision. 17.3.2 Without prejudice to the provision of Clause 17.3.1, the Maintenance Manual shall, in particular, include provisions for maintenance of Project Assets and shall provide for life cycle maintenance, routine maintenance and reactive maintenance which may be reasonably necessary for maintenance and repair of the Project Assets, including replacement thereof, such that its overall condition conforms to Good Industry Practice.
Maintenance Manual. 17.3.1 Not later than 180 (one hundred and eighty) days prior to the Scheduled Project Completion Date, the Concessionaire shall, in consultation with the Independent Engineer, evolve a repair and maintenance manual (the "Maintenance Manual") for the regular and preventive maintenance of the Project in conformity with the Specification and Standards, Maintenance Requirements, Safety Requirements and Good Industry Practice, and shall provide 5 (five) copies thereof to the Concessioning Authority and 2 (two) copies to the Independent Engineer. The Maintenance Manual shall be revised and updated once every 2 (two) years and the provisions of this Clause 17.3 shall apply, mutatis mutandis, to such revision.
Maintenance Manual. The Professional shall compile and provide a Maintenance Manual consisting of two parts: Part One Inventory shall contain a list of all systems and pieces of equipment to be maintained, and the technical information necessary to order spare parts. Manufacturer’s catalogs are considered useful adjuncts, but should not be substituted for the Inventory section of the Maintenance Manual. Part Two Maintenance Program shall contain the information necessary to perform breakdown, preventative and predictive maintenance, including written information regarding when and how often to perform maintenance in the most efficient and economical fashion to satisfy tenant needs.
AutoNDA by SimpleDocs
Maintenance Manual. 17.3.1 Not later than 180 (one hundred and eighty) days prior to the COD of Phase I, the Concessionaire shall, in consultation with the Monitoring Agency, evolve a repair and maintenance manual (the “Maintenance Manual”), for the regular and preventive maintenance of the Hospital in conformity with the Maintenance Requirements, Safety Requirements and Good Industry Practice and shall provide 1 (one) copy thereof, each to the Authority and the Monitoring Agency. Within 60 (sixty) days of receipt of the Maintenance Manual, the Authority shall review and convey its comments to the Concessionaire. The Concessionaire shall modify the Maintenance Manual, in accordance with the comments provided by the Authority and provide 5 (five copies thereof to the Authority and 2 (two) copies to the Monitoring Agency. 17.3.2 The Maintenance Manual, which shall outline the preventive, scheduled and reactive maintenance provisions, shall be revised and updated once every 2 (two) years and the provisions of this Clause 17.3 shall apply, mutatis mutandis, to such revision.
Maintenance Manual. Contractor shall, prior to completion of Contract, deliver to the County two (2) copies of a manual, assembled, indexed, and bound, for the County’s guidance, full details for care and maintenance of visible surfaces and of equipment included in Contract. Contractor shall, for this manual, obtain from Subcontractors literature of manufacturers relating to equipment, including motors; also furnish cuts, wiring diagrams, instruction sheets and other information pertaining to same that will be useful to the County in over-all operation and maintenance. Where the above- described manuals and data are called for under separate sections of the Specifications, they are to be included in the manual described in this General Requirement.
Maintenance Manual. 16.3.1 On or before COD, the Concessionaire shall, in consultation with the Independent Engineer(s), evolve a repair and maintenance manual (the "Maintenance Manual") for the regular and preventive maintenance of the Mandatory Development Obligations in conformity with the Specifications and Standards, Maintenance Requirements, Safety Requirements and Good Industry Practice, and shall provide 5 (five) copies thereof to the Authority and 2 (two) copies to the Independent Engineer(s). The Maintenance Manual shall be revised and updated once every 3 (three) years and the provisions of this Article 16.3 shall apply, mutatis mutandis, to such revision. 16.3.2 Without prejudice to the provision of Article 16.3.1, the Maintenance Manual shall, in particular, include provisions for maintenance of Mandatory Development Obligations and shall provide for life cycle maintenance, routine maintenance and reactive maintenance which may be reasonably necessary for maintenance and repair of the Mandatory Development Obligations, including replacement thereof, such that their overall condition conforms to Good Industry Practice.
Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!