Insulation Test. The meters shall be tested at pressure of 4kV for a period of 1 minute between all live terminals and earth.
Insulation TestUnless agreed otherwise with the Engineer, all circuits required to operate at voltages in excess of 70 V shall have a peak test voltage of 2 kV rms. 50 Hz applied for 1 minute, and for all circuits required to operate at voltages of less than 70 V shall have a peak test voltage of 500 V d.c. applied for 1 minute. All structural metal work and metal chassis on one site shall be connected to earth at one point to the approval of the Engineer.
Insulation Test. Insulation value of grouped C.T.'s, secondary to earth, using 1kV megger .......................
Insulation Test for Power Supply Cables (medium voltage and low voltage) and continuity tests on all wiring including tests for correctness of connection.
Insulation Test. Insulation test, thickness, tensile strength, elongation, insulation resistance etc. shall be subjected to all the test at work specified in I.E.C 60502.
Insulation Test. The meters shall be tested at pressure of 4kV for a period of 1 minute between all love terminals and earth. (All data should be clear mentioned and shown in one table with the same numbering as shown in SCHEDULE (1) ) Item Description Xxxxxxxx's reply 1 Name of manufacturer 2 Country of origin 3 type of meter 4 description of product 5 Operating system 6 manufacturing license 7 quality assurance certificate 8 standard IEC No……………..
Insulation Test. Polarity test
Insulation Test. The insulation value shall test shall be conducted using a DC insulation test set (Megger) at 1000 volts DC. The test shall be completed and recorded on each of the following items: Main Bus, U2A, U2B and Gen 9. Each test shall last 1 min. and shall be conducted from A Phase to B Phase B Phase to C phase A phase to C phase A phase to Ground B phase to Ground C phase to Ground Neutral to Ground * note * Remove Neutral Disconnect Link December 12, 2012: Energizing U2 Main Switchboard: After all testing in complete with acceptable test values and the visual inspection found all conditions the main switchboard is ready to close. Install all covers except for the main circuit breaker. Re-install the Neutral disconnect link. Close the cover for the U2 main 5000 A circuit Breaker.
Insulation Test. Insulation tests for each loop to ground shall be in accordance with the latest edition of NEMA TS 1.

Related to Insulation Test

  • Substance Abuse Testing The Parties agree that it is in the best interest of all concerned to promote a safe working environment. The Union has no objection to pre-employment substance abuse testing when required by the Employer and further, the Union has no objection to voluntary substance abuse testing to qualify for employment on projects when required by a project owner. The cost and scheduling of such testing shall be paid for and arranged by the Employer. The Union agrees to reimburse the Employer for any failed pre-access Alcohol and Drug test costs.

  • Stability Testing Patheon shall conduct stability testing on the Products in accordance with the protocols set out in the Specifications for the separate fees specified in Schedule C. Patheon shall not make any changes to these testing protocols without prior written approval from the Client. In the event that any batch of Products fails stability testing, Patheon and the Client shall jointly determine the proceedings and methods to be undertaken to investigate the causes of such failure, including which party shall bear the cost of such investigation, provided that Patheon shall not be liable for any such costs unless there has been a failure by it to provide the Manufacturing Services in accordance with the Specifications and cGMPs. Patheon will provide any and all data and results relating to the stability testing upon request by the Client.

  • Alcohol Testing Alcohol testing will be conducted by using an evidential breath testing device (EBT) approved by the National Highway Traffic Safety Administration. Non-EBT devices may be used for initial screening tests. A screening test will be conducted first. If the result is an alcohol concentration level of less than 0.02, the test is considered a negative test. If the alcohol concentration level is 0.02 or more, a second confirmation test will be conducted. Levels of .04 or greater on the confirmation test will be considered positive.

  • Laboratory Testing All laboratories selected by UPS Freight for analyzing Controlled Substances Testing will be HHS certified.

  • Drug Testing (A) The state and the PBA agree to drug testing of employees in accordance with section 112.0455, F.S., the Drug-Free Workplace Act. (B) All classes covered by this Agreement are designated special risk classes for drug testing purposes. Special risk means employees who are required as a condition of employment to be certified under Chapter 633 or Chapter 943, F.S. (C) An employee shall have the right to grieve any disciplinary action taken under section 112.0455, the Drug-Free Workplace Act, subject to the limitations on the grievability of disciplinary actions in Article 10. If an employee is not disciplined but is denied a demotion, reassignment, or promotion as a result of a positive confirmed drug test, the employee shall have the right to grieve such action in accordance with Article 6.

  • Random Drug Testing All employees covered by this Agreement shall be subject to random drug testing in accordance with Appendix D.

  • Reasonable Suspicion Testing All Employees Performing Safety-Sensitive Functions A. Reasonable suspicion testing for alcohol or controlled substances may be directed by the Employer for any employee performing safety-sensitive functions when there is reason to suspect that alcohol or controlled substance use may be adversely affecting the employee’s job performance or that the employee may present a danger to the physical safety of the employee or another. B. Specific objective grounds must be stated in writing that support the reasonable suspicion. Examples of specific objective grounds include but are not limited to: 1. Physical symptoms consistent with alcohol and/or controlled substance use; 2. Evidence or observation of alcohol or controlled substance use, possession, sale, or delivery; or 3. The occurrence of an accident(s) where a trained manager, supervisor or lead worker suspects alcohol or other controlled substance use may have been a factor.

  • Electrical appliance safety The Hirer shall ensure that any electrical appliances brought by them to the premises and used there shall be safe, in good working order, and used in a safe manner in accordance with the Electricity at Work Regulations 1989. Where a residual circuit breaker is provided the hirer must make use of it in the interests of public safety.

  • ODUF Testing 6.6.1 Upon request from TWTC, AT&T shall send ODUF test files to TWTC. The Parties agree to review and discuss the ODUF file content and/or format. For testing of usage results, AT&T shall request that TWTC set up a production (live) file. The live test may consist of TWTC’s employees making test calls for the types of services TWTC requests on ODUF. These test calls are logged by TWTC, and the logs are provided to AT&T. These logs will be used to verify the files. Testing will be completed within thirty (30) days from the date on which the initial test file was sent.

  • Closet I Urinal Requirements Employees Closets Urinals