Main Substation Transformer. (NOTE: If there are multiple transformers, data for each transformer should be provided. If final impedance data is not known at this time, the IC should supply typical data for use in completing the short-circuit portion of the System Impact Study (SIS).) Rating (ONAN/ONAF1/ONAF2): / / MVA / MVA / MVA Nominal Voltage for each winding (Low/High/Tertiary): / / kV / kV / kV Winding Connections (Low/High/Tertiary): / / (e.g. Delta, Wye-gnd) HV DETC (NLTC), LTC or None: Available Taps: Operating tap: kV Impedances: HV-LV, HV-TV, LV-TV, assuming 3-winding design, in per-unit on transformer self-cooled (ONAN) MVA Base Rating: Positive sequence Z1: HV-LV: R1: pu X1: pu HV-TV: R1: pu X1: pu LV-TV: R1: pu X1: pu Zero sequence Z0: HV-LV: R0: pu X0: pu HV-TV: R0: pu X0: pu LV-TV: R0: pu X0: pu
Appears in 3 contracts
Samples: Confidentiality Agreement, Generator Interconnection Agreement, Generator Interconnection Agreement
Main Substation Transformer. (NOTE: If there are multiple transformers, data for each transformer should be provided. If final impedance data is not known at this time, the IC should supply typical data for use in completing the short-circuit portion of the System Impact Study (SIS).) Rating (ONAN/ONAF1/ONAF2): / / MVA / MVA / MVA Nominal Voltage for each winding (Low/High/Tertiary): / / kV / kV / kV Winding Connections (Low/High/Tertiary): / / (e.g. Delta, Wye-gnd) HV DETC (NLTC), LTC or None: Available Taps: Operating tapTap: kV Impedances: HV-LV, HV-TV, LV-TV, assuming 3-winding design, in per-unit on transformer self-cooled (ONAN) MVA Base Rating: o Positive sequence Z1: HV-LV: R1: pu X1: pu o HV-TV: R1: pu X1: pu o LV-TV: R1: pu X1: pu o Zero sequence Z0: HV-LV: R0: pu X0: pu o HV-TV: R0: pu X0: pu o LV-TV: R0: pu X0: pu
Appears in 1 contract
Samples: Generator Interconnection Agreement
Main Substation Transformer. (NOTE: If there are multiple transformers, data for each transformer should be provided. If final impedance data is not known at this time, the IC should supply typical data for use in completing the short-circuit portion of the System Impact Study (SIS).) ). Rating (ONAN/ONAF1/ONAF2): / / MVA / MVA / MVA Nominal Voltage for each winding (Low/High/Tertiary): / / kV / kV / kV Winding Connections (Low/High/Tertiary): / / (e.g. Delta, Wye-gnd) HV DETC (NLTC), LTC or None: Available Taps: Operating tapTap: kV Impedances: HV-LV, HV-TV, LV-TV, assuming 3-winding design, in per-unit on transformer self-cooled (ONAN) MVA Base Rating: o Positive sequence Z1: HV-LV: R1: pu X1: pu o HV-TV: R1: pu X1: pu o LV-TV: R1: pu X1: pu o Zero sequence Z0: HV-LV: R0: pu X0: pu o HV-TV: R0: pu X0: pu o LV-TV: R0: pu X0: pu
Appears in 1 contract
Samples: Generator Interconnection Agreement