Mechanical Plant Operators (Plus Rates Sample Clauses

Mechanical Plant Operators (Plus Rates. These operatives shall be paid the basic plain time rate for labourers together with the following rates: - Category of Operatives Hourly Rate 20/07/18 £ p 20/07/19 £ p Power-Driven Tools Operative using Power-driven Tools such as Breakers, Percussive Drills, Picks and Spades, Rammers 0.51 0.53 Continued Category of Operatives Hourly Rate 20/07/18 £ p 20/07/19 £ p Compressors Mobile or portable Air Compressor, Operator of 0.54 0.56 Mobile Cranes Self-propelled Mobile Crane on Road wheels or Caterpillar tracks including Lorry mounted: capacity up to and including 2 tons 0.84 0.87 All other mobile cranes 2.44 2.53 Dumpers Over 0.8 cu metres up to and including 3.85 cu metres struck capacity 0.54 0.56 Demolition Rigged Excavators Category A - Materials processing. 0.84 0.87 Category B – Demolishing < 15 m. 1.34 1.39 Category C – Demolishing < 30 m. 1.71 1.77 Category D – All heights 1.98 2.05 Operative attending Cranes or Excavators (Banksman) 0.51 0.53 Front-End Shovels Up to and including 0.8 cu metres. Over 2.3 cu metres up to and including. 1.72 1.78 (d) Lorry Drivers Drivers of lorries shall be paid the following hourly rates: From 20/07/18 From 20/07/19 Class 1 £12.78 £13.23 Class 2 £12.02 £12.44 Class 3 £11.27 £11.66
AutoNDA by SimpleDocs

Related to Mechanical Plant Operators (Plus Rates

  • Current Operating Areas Where logging or road construction is in progress but not completed, unless agreed otherwise, Purchaser shall, before opera- tions cease annually, remove all temporary log culverts and construct temporary cross drains, drainage ditches, dips, berms, culverts, or other facilities needed to control erosion. Such protection shall be provided, prior to end of a Normal Operating Season, for all disturbed, unprotected ground that is not to be disturbed further prior to end of operations each year, including roads and associated fills, tractor roads, skid trails, and fire lines. When weather permits operations after Normal Operating Season, Pur- chaser shall keep such work on any additional disturbed areas as up to date as practicable.

  • Condition of the Contractor’s Property or Equipment The Contractor shall make the Property and/or equipment available to the Judicial Council, pursuant to the terms and conditions set forth in this Agreement. The Contractor shall immediately remedy any problem with the Property’s physical plant or equipment that impairs or diminishes the quality of the Program. The Contractor shall ensure the appropriate hot water, heating, and ventilation is provided at the Property during the Program, inclusive in the prices set forth herein.

  • Shift Operation When a three (3) shift operation is established by the Employer, the following conditions will apply: Those employees working on the day shift shall work eight (8) hours at the straight time rate. Those employees working on the afternoon shift shall work seven and one-half (7 1/2) hours per shift. A shift differential of one-seventh (1/7) shall be paid for all normal scheduled shift hours worked. Those employees working on the night shift shall work seven (7) hours per shift. A shift differential of one-fifth (1/5) shall be paid for all normal scheduled shift hours worked.

  • Petroleum Storage Systems A. At Company’s expense, Company will at all times comply with all federal, state, and local requirements, including but not limited to, the regulations of the FDEP as stated in Chapters 62-761 and 62-762, FAC, the requirements of the Federal Oil Pollution Prevention regulation found in Title 40 of the Code of Federal Regulations Part 112 (40 CFR part 112), as well as the requirements of the Environmental Protection Commission of Hillsborough County (EPC), as may be amended or replaced, pertaining to petroleum storage tank and piping system construction, operation, inspection, and compliance monitoring programs; release detection methods and procedures; maintenance; and preventative maintenance programs. Company will be responsible for all spillage, overflow, or escape of gases, petroleum or petroleum products, and for all fines and penalties in connection therewith. All petroleum storage systems will be registered by Company, and Company will display the registration placard as required by law.

  • Verizon OSS Facilities Any gateways, interfaces, databases, facilities, equipment, software, or systems, used by Verizon to provide Verizon OSS Services to CBB.

  • Contractor’s Equipment Payment for required equipment owned by the Construction Manager or an affiliate of the Construction Manager will be based solely on an hourly rate derived by dividing the current appropriate monthly rate by 176 hours. No payment will be made under any circumstances for repair costs, freight and transportation charges, fuel, lubricants, insurance, any other costs and expenses, or overhead and profit. Payment for such equipment made idle by delays attributable to the Government will be based on one-half the derived hourly rate under this subsection.

  • Participating TO’s Interconnection Facilities The Participating TO shall design, procure, construct, install, own and/or control the Participating TO’s Interconnection Facilities described in Appendix A at the sole expense of the Interconnection Customer. Unless the Participating TO elects to fund the capital for the Participating TO’s Interconnection Facilities, they shall be solely funded by the Interconnection Customer.

  • Provisioning of High Frequency Spectrum and Splitter Space 3.2.1 BellSouth will provide <<customer_name>> with access to the High Frequency Spectrum as follows:

  • Participating TO's Interconnection Facilities Construction The Participating TO's Interconnection Facilities shall be designed and constructed in accordance with Good Utility Practice. Upon request, within one hundred twenty (120) Calendar Days after the Commercial Operation Date, unless the Participating TO and Interconnection Customer agree on another mutually acceptable deadline, the Participating TO shall deliver to the Interconnection Customer and the CAISO the following “as-built” drawings, information and documents for the Participating TO's Interconnection Facilities [include appropriate drawings and relay diagrams]. The Participating TO will obtain control for operating and maintenance purposes of the Participating TO's Interconnection Facilities and Stand Alone Network Upgrades upon completion of such facilities. Pursuant to Article 5.2, the CAISO will obtain Operational Control of the Stand Alone Network Upgrades prior to the Commercial Operation Date.

  • Interconnection Facilities Engineering Procurement and Construction Interconnection Facilities, Network Upgrades, and Distribution Upgrades shall be studied, designed, and constructed pursuant to Good Utility Practice. Such studies, design and construction shall be based on the assumed accuracy and completeness of all technical information received by the Participating TO and the CAISO from the Interconnection Customer associated with interconnecting the Large Generating Facility.

Time is Money Join Law Insider Premium to draft better contracts faster.