Common use of Minimum space requirement for key areas Clause in Contracts

Minimum space requirement for key areas. The Concessionaire shall design and construct the Hospital Building in accordance with the minimum area requirements specified below. For the avoidance of doubt, the Concessionaire shall be free to provide for a greater area for any of the below mentioned facilities. Facilities/service areas Area requirement Front office waiting space Higher of 400 Sq. Ft or 1 sq.ft. per visitor Counter working space and circulation space 65 sq.ft. Receptionist counter 1.2 mt long Floor space for ICU beds 269 to 323 sq.ft. per bed (this includes support services) Floor space for paediatric ICU beds 108 to 129 sq.ft. per bed Floor space for high dependency unit 215 to 258 sq.ft. per bed Floor space for general xxxx 161 to 194 sq.ft. per bed Minimum distance between centres of two beds 2.5 mt. Minimum clearance at foot end of each bed 1.2 mt. Minimum area for apertures (windows/ventilators) 20% of the floor area (if on same wall) 15% of the floor area (if on opposite walls) Corridors width a. General atleast 2.4 mt. wide b. For OT area only 2.85 mt wide Clear roof height in general 3.6 mt measured at any point from floor to roof General operation theatre (OT) 32 xx.xx. Lithotripsy - procedure cum operating room (without need for anaesthesia) 24 xx.xx Facilities/service areas Area requirement Minimum distance between centres of two ICU beds 3.5 mt. Minimum clearance between head of bed to the wall 0.25 mt. Minimum floor space per bed in a xxxx/ room (excluding allowance for support services, bathroom, etc.) 7 xx.xx. Minimum floor space per bed in emergency/ acute xxxx/ rooms (excluding allowance for support services, bathroom, etc.) 10.5 xx.xx. Minimum floor space per bed in isolation xxxx/ rooms (excluding allowance for support services, bathroom, etc.) 12 xx.xx. Minimum floor space per bed in ICU xxxx/ rooms (excluding allowance for support services, bathroom, etc.) 20 xx.xx. CSSD {For Bed Capacity of 100: 70 xx.xx. For Bed Capacity of 200: 140 xx.xx.} Pharmaceutical and consumable stores {For Bed Capacity of 100: 50 xx.xx. For Bed Capacity of 200: 100 xx.xx.}1 Mortuary 50 xx.xx. Clear roof height for OT 4 m. measured at any point from floor to roof Super speciality OT (operating room area) for orthopaedics (with C-Arm/ fluoroscopy unit), cardiology (with cath lab), CTVS, neurosurgery and other tertiary care interventions 58 xx.xx. or 625 Sq.ft. per operating room (assuming one Table per operating room) Other space requirements for OT: zoning required 1. Protective zone: Includes reception, waiting area, trolley bay, changing room 2. Clean zone: Includes preoperative room, recovery Facilities/service areas Area requirement room, plaster room, staff room and stores 3. Sterile zone: OT suite, scrub room, anaesthesia induction room, set-up room 4. Disposal zone: Dirty utility room, disposal corridor Ramp Slope of 1:12 to 1:18 Emergency bed and surrounding space 10.5 xx.xx./ bed: in addition circulation space of 30% for nurse station, doctor duty room store, clean and dirty utility, dressing area, toilet etc. Labour room (labour table and surrounding areas) 10.5 xx.xx. or 113 Sq.ft./ labour table and 3.5 xx.xx. or 37.67 Sq.ft. for toilet. Pharmacy The size should be adequate to contain 5 percent of the total clinical visits to the OPD in one session at the rate of 0.8 m2 per patient. Laboratory – Clinical biochemistry 40 sq.ft. (additional 10 sq.ft.. for Biomedical Waste) Laboratory – Clinical pathology / cyto Pathology / haematology 30 sq.ft. and Washing area for each Histopathology 100 sq.ft. for block and gross storage including Grossing and washing area Microbiology - Bacteriology &parasitology 60 sq.ft. Microbiology – Mycology 30 sq.ft. Microbiology - Mycobacteriology 75 sq.ft. Microbiology – Virology 100 sq.ft. Microbiology - Immunoserology 30 sq.ft. Microbiology - Molecular biology 100 sq.ft. Facilities/service areas Area requirement Radiology - Wall thickness 2mm lead equivalent Radiology - Glass partition between the X-ray room and control panel room Through lead glass of at least 2mm thickness Radiology - CT scan / MRI scan unit 110 to 120 xx.xx. OPD waiting area 1 sq.ft./per average daily patient with minimum 400 sq.ft. of area OPD doctor’s chamber 12.0 xx.xx. 129.17 Sq.ft. Minor OT 20 xx.xx. NICU (Neonatal intensive care unit) 11.22 xx.xx. Isolation room 18.58 xx.xx. Private room (1 bed) 20-22 xx.xx. Semi private (2 bed) 10-11 xx.xx. per bed General xxxx (maximum of 10 beds) 10-12 xx.xx. per bed Measurement abbreviations used in the table above: • Meter: mt / m • Millimeter: mm • Foot/ Feet: ft • Square meter: xx.xx. • Square feet: sq.ft. ANNEXURE I HOSPITAL BUILDING SPECIFICATION {Hospital Building specifications are attached separately} XXXXXXXX XX STAFF ACCOMMODATION BUILDING SPECIFICATION {Staff Accommodation building specifications are attached separately} SCHEDULE 5 HUMAN RESOURCE REQUIREMENT

Appears in 1 contract

Samples: health.odisha.gov.in

AutoNDA by SimpleDocs

Minimum space requirement for key areas. The Concessionaire shall design and construct the Hospital Building in accordance with the minimum area requirements specified below. For the avoidance of doubt, the Concessionaire shall be free to provide for a greater area for any of the below mentioned facilities. Facilities/service areas Area requirement Front office waiting space Higher of 400 Sq. Ft or 1 sq.ft. per visitor Counter working space and circulation space 65 sq.ft. Receptionist counter 1.2 mt long Floor space for ICU beds 269 to 323 sq.ft. per bed (this includes support services) Floor space for paediatric ICU beds 108 to 129 sq.ft. per bed Floor space for high dependency unit 215 to 258 sq.ft. per bed Floor space for general xxxx 161 to 194 sq.ft. per bed Minimum distance between centres of two beds 2.5 mt. Minimum clearance at foot end of each bed 1.2 mt. Minimum area for apertures (windows/ventilators) 20% of the floor area (if on same wall) 15% of the floor area (if on opposite walls) Corridors width a. General atleast 2.4 mt. wide b. For OT area only 2.85 mt wide Clear roof height in general 3.6 mt measured at any point from floor to roof Facilities/service areas Area requirement General operation theatre (OT) 32 xx.xx. Lithotripsy - procedure cum operating room (without need for anaesthesia) 24 xx.xx Facilities/service areas Area requirement Minimum distance between centres of two ICU beds 3.5 mt. Minimum clearance between head of bed to the wall 0.25 mt. Minimum floor space per bed in a xxxx/ room (excluding allowance for support services, bathroom, etc.) 7 xx.xx. Minimum floor space per bed in emergency/ acute xxxx/ rooms (excluding allowance for support services, bathroom, etc.) 10.5 xx.xx. Minimum floor space per bed in isolation xxxx/ rooms (excluding allowance for support services, bathroom, etc.) 12 xx.xx. Minimum floor space per bed in ICU xxxx/ rooms (excluding allowance for support services, bathroom, etc.) 20 xx.xx. CSSD {For Bed Capacity of 100: 70 xx.xx. For Bed Capacity of 200: 140 xx.xx.} Pharmaceutical and consumable stores {For Bed Capacity of 100: 50 xx.xx. For Bed Capacity of 200: 100 xx.xx.}1 Mortuary 50 xx.xx. Clear roof height for OT 4 m. measured at any point from floor to roof Super speciality OT (operating room area) for orthopaedics (with C-Arm/ fluoroscopy unit), cardiology (with cath lab), CTVS, neurosurgery and other tertiary care interventions 58 xx.xx. or 625 Sq.ft. per operating room (assuming one Table per operating room) Other space requirements for OT: zoning required 1. Protective zone: Includes reception, waiting area, trolley bay, changing room 2. Clean zone: Includes preoperative room, recovery Facilities/service areas Area requirement room, plaster room, staff room and stores 3. Sterile zone: OT suite, scrub room, anaesthesia induction room, set-up room 4. Disposal zone: Dirty utility room, disposal corridor Ramp Slope of 1:12 to 1:18 Emergency bed and surrounding space 10.5 xx.xx./ bed: in addition circulation space of 30% for nurse station, doctor duty room store, clean and dirty utility, dressing area, toilet etc. Labour room (labour table and surrounding areas) 10.5 xx.xx. or 113 Sq.ft./ labour table and 3.5 xx.xx. or 37.67 Sq.ft. for toilet. Pharmacy The size should be adequate to contain 5 percent of the total clinical visits to the OPD in one session at the rate of 0.8 m2 per patient. Laboratory – Clinical biochemistry 40 sq.ft. (additional 10 sq.ft.. for Biomedical Waste) Laboratory – Clinical pathology / cyto Pathology / haematology 30 sq.ft. and Washing area for each Histopathology 100 sq.ft. for block and gross storage including Grossing and washing area Microbiology - Bacteriology &parasitology 60 sq.ft. Microbiology – Mycology 30 sq.ft. Microbiology - Mycobacteriology 75 sq.ft. Microbiology – Virology 100 sq.ft. Microbiology - Immunoserology 30 sq.ft. Microbiology - Molecular biology 100 sq.ft. Facilities/service areas Area requirement Radiology - Wall thickness 2mm lead equivalent Radiology - Glass partition between the X-ray room and control panel room Through lead glass of at least 2mm thickness Radiology - CT scan / MRI scan unit 110 to 120 xx.xx. OPD waiting area 1 sq.ft./per average daily patient with minimum 400 sq.ft. of area OPD doctor’s chamber 12.0 xx.xx. 129.17 Sq.ft. Minor OT 20 xx.xx. NICU (Neonatal intensive care unit) 11.22 xx.xx. Isolation room 18.58 xx.xx. Private room (1 bed) 20-22 xx.xx. Semi private (2 bed) 10-11 xx.xx. per bed General xxxx (maximum of 10 beds) 10-12 xx.xx. per bed Measurement abbreviations used in the table above: • Meter: mt / m • Millimeter: mm • Foot/ Feet: ft • Square meter: xx.xx. • Square feet: sq.ft. ANNEXURE I HOSPITAL BUILDING SPECIFICATION {Hospital Building specifications are attached separately} XXXXXXXX XX STAFF ACCOMMODATION BUILDING SPECIFICATION {Staff Accommodation building specifications are attached separately} SCHEDULE 5 HUMAN RESOURCE REQUIREMENT)

Appears in 1 contract

Samples: health.odisha.gov.in

Minimum space requirement for key areas. The Concessionaire shall design and construct the Hospital Building in accordance with the minimum area requirements specified below. For the avoidance of doubt, the Concessionaire shall be free to provide for a greater area for any of the below mentioned facilities. Facilities/service areas Area requirement Front office waiting space Higher of 400 Sq. Ft or 1 sq.ft. per visitor Counter working space and circulation space 65 sq.ft. Receptionist counter 1.2 mt long Floor space for ICU beds 269 to 323 sq.ft. per bed (this includes support services) Floor space for paediatric ICU beds 108 to 129 sq.ft. per bed Floor space for high dependency unit 215 to 258 sq.ft. per bed Floor space for general xxxx 161 to 194 sq.ft. per bed Minimum distance between centres of two beds 2.5 mt. Minimum clearance at foot end of each bed 1.2 mt. Minimum area for apertures (windows/ventilators) 20% of the floor area (if on same wall) 15% of the floor area (if on opposite walls) Corridors width a. General atleast 2.4 mt. wide Facilities/service areas Area requirement b. For OT area only 2.85 mt wide Clear roof height in general 3.6 mt measured at any point from floor to roof General operation theatre (OT) 32 xx.xx. Lithotripsy - procedure cum operating room (without need for anaesthesia) 24 xx.xx Facilities/service areas Area requirement Minimum distance between centres of two ICU beds 3.5 mt. Minimum clearance between head of bed to the wall 0.25 mt. Minimum floor space per bed in a xxxx/ room (excluding allowance for support services, bathroom, etc.) 7 xx.xx. Minimum floor space per bed in emergency/ acute xxxx/ rooms (excluding allowance for support services, bathroom, etc.) 10.5 xx.xx. Minimum floor space per bed in isolation xxxx/ rooms (excluding allowance for support services, bathroom, etc.) 12 xx.xx. Minimum floor space per bed in ICU xxxx/ rooms (excluding allowance for support services, bathroom, etc.) 20 xx.xx. CSSD {For Bed Capacity of 100: 70 xx.xx. For Bed Capacity of 200: 140 xx.xx.} Pharmaceutical and consumable stores {For Bed Capacity of 100: 50 xx.xx. For Bed Capacity of 200: 100 xx.xx.}1 Mortuary 50 xx.xx. Clear roof height for OT 4 m. measured at any point from floor to roof Facilities/service areas Area requirement Super speciality OT (operating room area) for orthopaedics (with C-Arm/ fluoroscopy unit), cardiology (with cath lab), CTVS, neurosurgery and other tertiary care interventions 58 xx.xx. or 625 Sq.ft. per operating room (assuming one Table per operating room) Other space requirements for OT: zoning required 1. Protective zone: Includes reception, waiting area, trolley bay, changing room 2. Clean zone: Includes preoperative room, recovery Facilities/service areas Area requirement room, plaster room, staff room and stores 3. Sterile zone: OT suite, scrub room, anaesthesia induction room, set-up room 4. Disposal zone: Dirty utility room, disposal corridor Ramp Slope of 1:12 to 1:18 Emergency bed and surrounding space 10.5 xx.xx./ xx.xx. / bed: in addition addition, circulation space of 30% for nurse station, doctor duty room store, clean and dirty utility, dressing area, toilet etc. Labour room (labour table and surrounding areas) 10.5 xx.xx. or 113 Sq.ft./ labour table and 3.5 xx.xx. or 37.67 Sq.ft. for toilet. Pharmacy The size should be adequate to contain 5 percent of the total clinical visits to the OPD in one session at the rate of 0.8 m2 per patient. Laboratory – Clinical biochemistry 40 sq.ft. (additional 10 sq.ft.. for Biomedical Waste) Laboratory – Clinical pathology / cyto Pathology / haematology 30 sq.ft. and Washing area for each Facilities/service areas Area requirement Histopathology 100 sq.ft. for block and gross storage including Grossing and washing area Microbiology - Bacteriology &parasitology 60 sq.ft. Microbiology – Mycology 30 sq.ft. Microbiology - Mycobacteriology 75 sq.ft. Microbiology – Virology 100 sq.ft. Microbiology - Immunoserology 30 sq.ft. Microbiology - Molecular biology 100 sq.ft. Facilities/service areas Area requirement Radiology - Wall thickness 2mm lead equivalent Radiology - Glass partition between the X-ray room and control panel room Through lead glass of at least 2mm thickness Radiology - CT scan / MRI scan unit 110 to 120 xx.xx. OPD waiting area 1 sq.ft./per average daily patient with minimum 400 sq.ft. of area OPD doctor’s chamber 12.0 xx.xx. 129.17 Sq.ft. Minor OT 20 xx.xx. NICU (Neonatal intensive care unit) 11.22 xx.xx. Isolation room 18.58 xx.xx. Private room (1 bed) 20-22 xx.xx. Semi private (2 bed) 10-11 xx.xx. per bed General xxxx (maximum of 10 beds) 10-12 xx.xx. per bed Measurement abbreviations used in the table above: • Meter: mt / m • Millimeter: mm • Foot/ Feet: ft • Square meter: xx.xx. • Square feet: sq.ft. ANNEXURE I HOSPITAL BUILDING SPECIFICATION {Hospital Building specifications are attached separately} XXXXXXXX XX STAFF ACCOMMODATION BUILDING SPECIFICATION {Staff Accommodation building specifications are attached separately} SCHEDULE 5 HUMAN RESOURCE REQUIREMENT

Appears in 1 contract

Samples: health.odisha.gov.in

Minimum space requirement for key areas. The Concessionaire shall design and construct the Hospital Building in accordance with the minimum area requirements specified below. For the avoidance of doubt, the Concessionaire shall be free to provide for a greater area for any of the below mentioned facilities. Facilities/service areas Area requirement Front office waiting space Higher of 400 Sq. Ft or 1 sq.ft. per visitor Counter working space and circulation space 65 sq.ft. Receptionist counter 1.2 mt long Floor space for ICU beds 269 to 323 sq.ft. per bed (this includes support services) Floor space for paediatric ICU beds 108 to 129 sq.ft. per bed Floor space for high dependency unit 215 to 258 sq.ft. per bed Floor space for general xxxx 161 to 194 sq.ft. per bed Minimum distance between centres of two beds 2.5 mt. Minimum clearance at foot end of each bed 1.2 mt. Minimum area for apertures (windows/ventilators) 20% of the floor area (if on same wall) 15% of the floor area (if on opposite walls) Corridors width a. General atleast 2.4 mt. wide b. For OT area only 2.85 mt wide Clear roof height in general 3.6 mt measured at any point from floor to roof General operation theatre (OT) 32 xx.xx. Lithotripsy - procedure cum operating room (without need for anaesthesia) 24 xx.xx Facilities/service areas Area requirement Minimum distance between centres of two ICU beds 3.5 mt. Minimum clearance between head of bed to the wall 0.25 mt. Minimum floor space per bed in a xxxx/ room (excluding allowance for support services, bathroom, etc.) 7 xx.xx. Minimum floor space per bed in emergency/ acute xxxx/ rooms (excluding allowance for support services, bathroom, etc.) 10.5 xx.xx. Minimum floor space per bed in isolation xxxx/ rooms (excluding allowance for support services, bathroom, etc.) 12 xx.xx. Minimum floor space per bed in ICU xxxx/ rooms (excluding allowance for support services, bathroom, etc.) 20 xx.xx. CSSD {For Bed Capacity of 100: 70 xx.xx. For Bed Capacity of 200: 140 xx.xx.} Pharmaceutical and consumable stores {For Bed Capacity of 100: 50 xx.xx. For Bed Capacity of 200: 100 xx.xx.}1 Mortuary 50 xx.xx. Clear roof height for OT 4 m. measured at any point from floor to roof Super speciality OT (operating room area) for orthopaedics (with C-Arm/ fluoroscopy unit), cardiology (with cath lab), CTVS, neurosurgery and other tertiary care interventions 58 xx.xx. or 625 Sq.ft. per operating room (assuming one Table per operating room) Other space requirements for OT: zoning required 1. Protective zone: Includes reception, waiting area, trolley bay, changing room 2. Clean zone: Includes preoperative room, recovery Facilities/service areas Area requirement room, plaster room, staff room and stores 3. Sterile zone: OT suite, scrub room, anaesthesia induction room, set-up room 4. Disposal zone: Dirty utility room, disposal corridor Ramp Slope of 1:12 to 1:18 Emergency bed and surrounding space 10.5 xx.xx./ xx.xx. / bed: in addition addition, circulation space of 30% for nurse station, doctor duty room store, clean and dirty utility, dressing area, toilet etc. Labour room (labour table and surrounding areas) 10.5 xx.xx. or 113 Sq.ft./ labour table and 3.5 xx.xx. or 37.67 Sq.ft. for toilet. Pharmacy The size should be adequate to contain 5 percent of the total clinical visits to the OPD in one session at the rate of 0.8 m2 per patient. Laboratory – Clinical biochemistry 40 sq.ft. (additional 10 sq.ft.. for Biomedical Waste) Laboratory – Clinical pathology / cyto Pathology / haematology 30 sq.ft. and Washing area for each Histopathology 100 sq.ft. for block and gross storage including Grossing and washing area Microbiology - Bacteriology &parasitology 60 sq.ft. Microbiology – Mycology 30 sq.ft. Microbiology - Mycobacteriology 75 sq.ft. Microbiology – Virology 100 sq.ft. Microbiology - Immunoserology 30 sq.ft. Microbiology - Molecular biology 100 sq.ft. Facilities/service areas Area requirement Radiology - Wall thickness 2mm lead equivalent Radiology - Glass partition between the X-ray room and control panel room Through lead glass of at least 2mm thickness Radiology - CT scan / MRI scan unit 110 to 120 xx.xx. OPD waiting area 1 sq.ft./per average daily patient with minimum 400 sq.ft. of area OPD doctor’s chamber 12.0 xx.xx. 129.17 Sq.ft. Minor OT 20 xx.xx. NICU (Neonatal intensive care unit) 11.22 xx.xx. Isolation room 18.58 xx.xx. Private room (1 bed) 20-22 xx.xx. Semi private (2 bed) 10-11 xx.xx. per bed General xxxx (maximum of 10 beds) 10-12 xx.xx. per bed Measurement abbreviations used in the table above: • Meter: mt / m • Millimeter: mm • Foot/ Feet: ft • Square meter: xx.xx. • Square feet: sq.ft. ANNEXURE I HOSPITAL BUILDING SPECIFICATION {Hospital Building specifications are attached separately} XXXXXXXX XX STAFF ACCOMMODATION BUILDING SPECIFICATION {Staff Accommodation building specifications are attached separately} SCHEDULE 5 HUMAN RESOURCE REQUIREMENT

Appears in 1 contract

Samples: health.odisha.gov.in

AutoNDA by SimpleDocs

Minimum space requirement for key areas. The Concessionaire shall design and construct the Hospital Building in accordance with the minimum area requirements specified below. For the avoidance of doubt, the Concessionaire shall be free to provide for a greater area for any of the below mentioned facilities. Facilities/service areas Area requirement Front office waiting space Higher of 400 Sq. Ft or 1 sq.ft. per visitor Counter working space and circulation space 65 sq.ft. Receptionist counter 1.2 mt long Floor space for ICU beds 269 to 323 sq.ft. per bed (this includes support services) Floor space for paediatric ICU beds 108 to 129 sq.ft. per bed Floor space for high dependency unit 215 to 258 sq.ft. per bed Floor space for general xxxx 161 to 194 sq.ft. per bed Minimum distance between centres of two beds 2.5 mt. Minimum clearance at foot end of each bed 1.2 mt. Minimum area for apertures (windows/ventilators) 20% of the floor area (if on same wall) 15% of the floor area (if on opposite walls) Corridors width a. General atleast 2.4 mt. wide b. For OT area only 2.85 mt wide Clear roof height in general 3.6 mt measured at any point from floor to roof General operation theatre (OT) 32 xx.xx. Lithotripsy - procedure cum operating room (without need for anaesthesia) 24 xx.xx Facilities/service areas Area requirement Minimum distance between centres of two ICU beds 3.5 mt. Facilities/service areas Area requirement Minimum clearance between head of bed to the wall 0.25 mt. Minimum floor space per bed in a xxxx/ room (excluding allowance for support services, bathroom, etc.) 7 xx.xx. Minimum floor space per bed in emergency/ acute xxxx/ rooms (excluding allowance for support services, bathroom, etc.) 10.5 xx.xx. Minimum floor space per bed in isolation xxxx/ rooms (excluding allowance for support services, bathroom, etc.) 12 xx.xx. Minimum floor space per bed in ICU xxxx/ rooms (excluding allowance for support services, bathroom, etc.) 20 xx.xx. CSSD {For Bed Capacity of 100: 70 xx.xx. For Bed Capacity of 200: 140 xx.xx.} Pharmaceutical and consumable stores {For Bed Capacity of 100: 50 xx.xx. For Bed Capacity of 200: 100 xx.xx.}1 Mortuary 50 xx.xx. Clear roof height for OT 4 m. measured at any point from floor to roof Super speciality OT (operating room area) for orthopaedics (with C-Arm/ fluoroscopy unit), cardiology (with cath lab), CTVS, neurosurgery and other tertiary care interventions 58 xx.xx. or 625 Sq.ft. per operating room (assuming one Table per operating room) Other space requirements for OT: zoning required 1. Protective zone: Includes reception, waiting area, trolley bay, changing room 2. Clean zone: Includes preoperative room, recovery Facilities/service areas Area requirement room, plaster room, staff room and stores 3. Sterile zone: OT suite, scrub room, anaesthesia induction room, set-up room 4. Disposal zone: Dirty utility room, disposal corridor Ramp Slope of 1:12 to 1:18 Emergency bed and surrounding space 10.5 xx.xx./ bed: in addition circulation space of 30% for nurse station, doctor duty room store, clean and dirty utility, dressing area, toilet etc. Labour room (labour table and surrounding areas) 10.5 xx.xx. or 113 Sq.ft./ labour table and 3.5 xx.xx. or 37.67 Sq.ft. for toilet. Pharmacy The size should be adequate to contain 5 percent of the total clinical visits to the OPD in one session at the rate of 0.8 m2 per patient. Laboratory – Clinical biochemistry 40 sq.ft. (additional 10 sq.ft.. for Biomedical Waste) Laboratory – Clinical pathology / cyto Pathology / haematology 30 sq.ft. and Washing area for each Histopathology 100 sq.ft. for block and gross storage including Grossing and washing area Microbiology - Bacteriology &parasitology 60 sq.ft. Microbiology – Mycology 30 sq.ft. Microbiology - Mycobacteriology 75 sq.ft. Microbiology – Virology 100 sq.ft. Microbiology - Immunoserology 30 sq.ft. Microbiology - Molecular biology 100 sq.ft. Facilities/service areas Area requirement Radiology - Wall thickness 2mm lead equivalent Facilities/service areas Area requirement Radiology - Glass partition between the X-ray room and control panel room Through lead glass of at least 2mm thickness Radiology - CT scan / MRI scan unit 110 to 120 xx.xx. OPD waiting area 1 sq.ft./per average daily patient with minimum 400 sq.ft. of area OPD doctor’s chamber 12.0 xx.xx. 129.17 Sq.ft. Minor OT 20 xx.xx. NICU (Neonatal intensive care unit) 11.22 xx.xx. Isolation room 18.58 xx.xx. Private room (1 bed) 20-22 xx.xx. Semi private (2 bed) 10-11 xx.xx. per bed General xxxx (maximum of 10 beds) 10-12 xx.xx. per bed Measurement abbreviations used in the table above: • Meter: mt / m • Millimeter: mm • Foot/ Feet: ft • Square meter: xx.xx. • Square feet: sq.ft. ANNEXURE I HOSPITAL BUILDING SPECIFICATION {Hospital Building building specifications are attached separately} XXXXXXXX XX STAFF ACCOMMODATION BUILDING SPECIFICATION {Staff Accommodation accommodation building specifications are attached separately} SCHEDULE 5 HUMAN RESOURCE REQUIREMENT

Appears in 1 contract

Samples: health.odisha.gov.in