Network interface test Clause Samples

Network interface test. The network interface test is done from an internal call generator in the AGE of one Party and is answered by an internal responder in the AGE of the other Party. The called party number is D68F and the Nature of address is “Unknown”, requesting a loop-back device in the other network. A test pattern generator/receiver is connected to the call sender, to do a BER test. The test routine seizes all free or blocked trunks of an interconnect circuit group one after another in the test window 22:00 – 06:00. Every trunk should be tested at least once in a week. These tests are initiated from both networks: Pattern generator/receiver (loop-back) AGE BGC Pattern generator/receiver

Related to Network interface test

  • Network Interface Device 2.7.1 The NID is defined as any means of interconnection of the customer’s premises wiring to BellSouth’s distribution plant, such as a cross-connect device used for that purpose. The NID is a single line termination device or that portion of a multiple line termination device required to terminate a single line or circuit at the premises. The NID features two (2) independent ▇▇▇▇▇▇▇▇ or divisions that separate the service provider’s network from the customer’s premises wiring. Each chamber or division contains the appropriate connection points or posts to which the service provider and the customer each make their connections. The NID provides a protective ground connection and is capable of terminating cables such as twisted pair cable. 2.7.2 BellSouth shall permit NewPhone to connect NewPhone’s Loop facilities to the customer’s premises wiring through the BellSouth NID or at any other technically feasible point.

  • Network Interconnection Architecture Each Party will plan, design, construct and maintain the facilities within their respective systems as are necessary and proper for the provision of traffic covered by this Agreement. These facilities include but are not limited to, a sufficient number of trunks to the point of interconnection with the tandem company, and sufficient interoffice and interexchange facilities and trunks between its own central offices to adequately handle traffic between all central offices within the service areas at a P.01 grade of service or better. The provisioning and engineering of such services and facilities will comply with generally accepted industry methods and practices, and will observe the rules and regulations of the lawfully established tariffs applicable to the services provided.

  • Interface A defined set of transmission facilities that separate Load Zones and that separate the NYCA from adjacent Control Areas. Investor-Owned Transmission Owners. A Transmission Owner that is owned by private investors. At the present time these include: Central ▇▇▇▇▇▇ Gas & Electric Corporation, Consolidated Edison Company of New York, Inc., New York State Electric & Gas Corporation, Niagara Mohawk Power Corporation, Orange and Rockland Utilities, Inc., and Rochester Gas and Electric Corporation.

  • Network Interconnection Methods 3.1 The Interconnection provided herein may not be used solely for the purpose of originating a Party’s own interexchange traffic.

  • Acceptance Testing At the time of installation of a LIS trunk group, and at no additional charge, acceptance tests will be performed to ensure that the service is operational and meets the applicable technical parameters.