Electric Storage Resources Developer interconnecting an electric storage resource shall establish an operating range in Appendix C of its LGIA that specifies a minimum state of charge and a maximum state of charge between which the electric storage resource will be required to provide primary frequency response consistent with the conditions set forth in Articles 9.5.5, 9.5.5.1, 9.5.5.2, and 9.5.5.3 of this Agreement. Appendix C shall specify whether the operating range is static or dynamic, and shall consider (1) the expected magnitude of frequency deviations in the interconnection; (2) the expected duration that system frequency will remain outside of the deadband parameter in the interconnection; (3) the expected incidence of frequency deviations outside of the deadband parameter in the interconnection; (4) the physical capabilities of the electric storage resource; (5) operational limitations of the electric storage resources due to manufacturer specification; and (6) any other relevant factors agreed to by the NYISO, Connecting Transmission Owner, and Developer. If the operating range is dynamic, then Appendix C must establish how frequently the operating range will be reevaluated and the factors that may be considered during its reevaluation. Developer’s electric storage resource is required to provide timely and sustained primary frequency response consistent with Article 9.5.5.2 of this Agreement when it is online and dispatched to inject electricity to the New York State Transmission System and/or receive electricity from the New York State Transmission System. This excludes circumstances when the electric storage resource is not dispatched to inject electricity to the New York State Transmission System and/or dispatched to receive electricity from the New York State Transmission System. If Developer’s electric storage resource is charging at the time of a frequency deviation outside of its deadband parameter, it is to increase (for over-frequency deviations) or decrease (for under-frequency deviations) the rate at which it is charging in accordance with its droop parameter. Developer’s electric storage resource is not required to change from charging to discharging, or vice versa, unless the response necessitated by the droop and deadband settings requires it to do so and it is technically capable of making such a transition.
Energy Cooperation shall focus on: (a) renewable energy; (b) promoting the saving of energy; (c) applied research relating to networks of databases linking the two Parties' economic and social operators; (d) backing efforts to modernise and develop energy networks and the interconnection of such networks with Community networks.
Electric Service 1. The Authority shall make available Electric Service to enable the Customer to receive the Allocation in accordance with this Agreement, Service Tariff No. WNY-2 and the Rules. 2. The Customer shall not be entitled to receive Electric Service under this Agreement for any EP and/or RP allocation unless such EP and/or RP allocation is identified in Schedule A. 3. The Authority will provide, and the Customer shall accept and pay for, Electric Service with respect to the Allocation specified in Schedule A. If Schedule C specifies a Takedown Schedule for the Allocation, the Authority will provide, and the Customer shall accept and pay for, Electric Service with respect to the Allocation in accordance with such Takedown Schedule. 4. The Authority shall provide UCAP in amounts necessary to meet the Customer’s NYISO UCAP requirements associated with the Allocation in accordance with the NYISO Tariffs. The Customer shall be responsible to pay the Authority for such UCAP in accordance with Service Tariff No. WNY-2. 5. The provision of Electric Service associated with the Allocation is an unbundled service separate from the transmission and delivery of power and energy to the Customer. The Customer acknowledges and agrees that Customer’s local electric utility, not the Authority, shall be responsible for delivering the Allocation to the Facility specified in Schedule A in accordance with the applicable Utility Tariff(s). 6. The Contract Demand for the Customer’s Allocation may be modified by the Authority if the amount of Firm Power and Firm Energy available for sale as EP or RP from the Project is modified as required to comply with any ruling, order, or decision of any regulatory or judicial body having jurisdiction, including but not limited to FERC. Any such modification will be made on a pro rata basis to all EP and RP customers, as applicable, based on the terms of such ruling, order, or decision. 7. The Contract Demand may not exceed the Allocation. 8. The Customer’s Facility must be metered by the Customer’s local electric utility in a manner satisfactory to the Authority, or another metering arrangement satisfactory to the Authority must be provided (collectively, “Metering Arrangement”). A Metering Arrangement that is not satisfactory to the Authority shall be grounds, after notice to the Customer, for the Authority to modify, withhold, suspend, or terminate Electric Service to the Customer. If a Metering Arrangement is not made to conform to the Authority’s requirements within thirty
Energy Conservation The Contractor agrees to comply with mandatory standards and policies relating to energy efficiency which are contained in the state energy conservation plan issued in compliance with the Energy Policy and Conservation Act.
Public Utilities No Restricted Entity or Affiliate thereof is a "holding company," or a "subsidiary company" of a "holding company," or an "affiliate" of a "holding company" or of a "subsidiary company" of a "holding company," within the meaning of the Public Utility Holding Company Act of 1935, as amended. No Restricted Entity or Affiliate thereof is a regulated public utility.
Electric If Customer has selected an Electricity Fixed Rate on the Application, Customer’s Price will be based on the Fixed Rate(s) which includes Local and State taxes, Gross Receipts Tax (GRT), PJM Adjustment (defined below) charges and adjustments and Utility applied charges and/or fees related to generation, plus the Administration Charge, which includes, Electricity Balancing Amount and third party utility and billing charges.
COMMON UTILITIES Expenses for serving/supply of common facilities and utilities and all charges incidental thereto.
CERTIFICATION REGARDING BOYCOTTING CERTAIN ENERGY COMPANIES (Texas law as of September 1, 2021) By submitting a proposal to this Solicitation, you certify that you agree, when it is applicable, to the following required by Texas law as of September 1, 2021: If (a) company is not a sole proprietorship; (b) company has ten (10) or more full-time employees; and (c) this contract has a value of $100,000 or more that is to be paid wholly or partly from public funds, the following certification shall apply; otherwise, this certification is not required. Pursuant to Tex. Gov’t Code Ch. 2274 of SB 13 (87th session), the company hereby certifies and verifies that the company, or any wholly owned subsidiary, majority-owned subsidiary, parent company, or affiliate of these entities or business associations, if any, does not boycott energy companies and will not boycott energy companies during the term of the contract. For purposes of this contract, the term “company” shall mean an organization, association, corporation, partnership, joint venture, limited partnership, limited liability partnership, or limited liability company, that exists to make a profit. The term “boycott energy company” shall mean “without an ordinary business purpose, refusing to deal with, terminating business activities with, or otherwise taking any action intended to penalize, inflict economic harm on, or limit commercial relations with a company because the company (a) engages in the exploration, production, utilization, transportation, sale, or manufacturing of fossil fuel-based energy and does not commit or pledge to meet environmental standards beyond applicable federal and state law, or (b) does business with a company described by paragraph (a).” See Tex. Gov’t Code § 809.001(1).
Entities that Boycott Energy Companies In accordance with Senate Bill 13, Acts 2021, 87th Leg., R.S., pursuant to Section 2274.002 (eff. Sept. 1, 2023, Section 2276.002, pursuant to House Bill 4595, Acts 2023, 88th Leg., R.S.) of the Texas Government Code (relating to prohibition on contracts with companies boycotting certain energy companies), Contractor represents and warrants that: (1) it does not, and will not for the duration of the Contract, boycott energy companies or (2) the verification required by Section 2274.002 (eff. Sept. 1, 2023, Section 2276.002, pursuant to House Bill 4595, Acts 2023, 88th Leg., R.S.) of the Texas Government Code does not apply to the Contract. If circumstances relevant to this provision change during the course of the Contract, Contractor shall promptly notify System Agency.
Services and Utilities (a) Landlord shall provide the following services and utilities during normal business hours on all days except Saturdays, Sundays, and federal and state holidays, or unless otherwise stated below. Cost of such services shall be included as an Operating Cost. (i) when necessary during normal business hours, central heating and air conditioning in the Premises and the Common Areas at temperature levels customary for comparable office buildings in the immediate vicinity (Landlord and Tenant agree that Tenant shall have the right to operate the HVAC system serving the Premises on an after-hours basis and shall pay for such expense in accordance with Section 8(b)); (ii) janitorial services five business days per week; and (iii) three passenger elevators, to be used in common with other tenants, except for the occasion of a temporary repair or replacement of the elevators. “Normal business hours” for purposes of clause (a) above shall be deemed to mean the periods from 8:00 a.m. until 6:00 p.m. on business days (Monday through Friday) and from 8:00 a.m. until 1:00 p.m. on Saturdays. Tenant shall nonetheless have access to the Premises and elevators seven (7) days a week, twenty-four (24) hours a day, subject to and in accordance with any security procedures that Landlord may have in place. (b) Tenant shall pay Tenant’s pro rata share of Tenant Electric. In addition, Tenant shall pay for all costs of after-hours HVAC service used by Tenant at an hourly rate mutually agreed upon by Landlord and Tenant. Electric current supplied to or used in the Premises shall be set at the rate prevailing for Tenant’s class of use as established by the company or companies chosen by Landlord or its designee to provide electricity to the Premises. Upon reasonable prior notice, Landlord or its designated electric service provider may have access to the Premises to install equipment necessary to deliver electric service to the Premises or the Building provided that Landlord or the utility company shall restore the Premises to its condition prior to the commencement of such work. Landlord reserves the right to switch electricity providers, if legally permissible, at any time. Landlord shall not be liable to Tenant for damages arising as a result of service interruptions caused by any electric service provider. Electric current supplied to or used in the Premise shall be measured by a submeter. (c) Any failure by the Landlord to furnish any of the foregoing services or utilities, resulting from circumstances beyond the Landlord’s reasonable control or from interruption of such services due to repairs or maintenance, shall not render the Landlord liable in any respect for damages to either person or property, nor be construed as an eviction of the Tenant, nor cause an abatement of rent hereunder, nor relieve the Tenant from any of its obligations hereunder, unless caused by Landlord or its agents, employees and/or contractors. If any public utility or governmental body shall require the Landlord or the Tenant to restrict the consumption of any utility or reduce any service for the Premises or the Building, the Landlord and the Tenant shall comply with such requirements, whether or not the services and utilities referred to in this section 8 are thereby reduced or otherwise affected, without any liability on the part of the Landlord to the Tenant or any other person or any reduction or adjustment in rent payable hereunder. The Landlord and its agents shall be permitted reasonable access to the Premises for the purpose of installing and servicing systems within the Premises deemed necessary by the Landlord to provide the services and utilities referred to in this Section 8 to the Tenant and other tenants in the Building. (d) Tenant shall not at any time overburden or exceed the capacity of the mains, feeders, ducts, conduits, or other facilities by which such utilities are supplied to, distributed in or serve the Premises beyond normal office uses. If Tenant desires to install any equipment which shall require additional utility facilities or utility facilities of a greater capacity than the facilities existing, such installation shall be subject to Landlord’s prior written approval of Tenant’s plans and specifications therefor. If such installation is approved by Landlord and if Landlord provides such additional facilities to accommodate Tenant’s installation, Tenant agrees to pay Landlord, on demand, the cost for providing such additional utility facilities or utility facilities of greater capacity. Landlord shall not be responsible for providing any meters or other devices for the measurement of utilities supplied to the Premises. In addition, if Tenant requires lighting other than the standard lighting provided by Landlord for the Building, Tenant shall be required to pay Landlord on demand for the additional costs of such lighting, including light bulb replacement. (e) Landlord shall cause to be operated a trash removal service for the Project, the costs and expenses of which shall be a part of Operating Costs. In the event that Tenant’s use of the Premises requires trash removal services in excess of that required for standard office tenants, Tenant shall pay to Landlord, as additional rent all costs and expenses in excess of the trash removal costs which are attributable to such excess usage. (f) In the event Tenant wishes, at any time, to utilize the services of a telecommunications provider who is not then authorized by the Landlord to provide telecommunications services to tenants in the Building, such provider shall be permitted to install its lines or other equipment within the Building after it secures the prior written approval of the Landlord. Landlord hereby authorizes Verizon, Worldcom, and Telephonet to provide telecommunication services to the Building. Tenant shall use its best efforts to get such vendors to execute license and access agreements reasonably acceptable to Landlord provided that such agreements do not materially alter the telecommunication service to Tenant or increase the costs to Tenant of such telecommunication services. Landlord’s approval shall not be deemed any kind of warranty or representation by Landlord, including, without limitation, any warranty or representation as to the suitability, competence, or financial strength of the provider. Without limitation of the foregoing standard, unless all of the following conditions are satisfied to Landlord’s satisfaction, it shall be reasonable for Landlord to refuse to give its approval: (i) Landlord shall incur no expense whatsoever with respect to any aspect of the provider’s provision of its services, including, without limitation, the costs of installation, materials and services; (ii) the provider shall agree to use the Building’s central communications distribution system (“CDS”) to deliver telecommunications services to Tenant (unless the CDS is not physically capable of delivering such services); (iii) prior to commencement of any work in or about the Building by the provider, the provider shall supply Landlord with such written indemnities, insurance, financial statements, and such other items as Landlord reasonably determines to be necessary to protect its financial interests and the interests of the Building relating to the proposed activities of the provider; (iv) the provider agrees in writing to abide by such rules and regulations, Building and other codes, job site rules and such other requirements as are reasonably determined by Landlord to be necessary to protect the interests of the Building, the tenants in the Building, and Landlord, in the same or similar manner as Landlord has the right to protect itself and the Building with respect to proposed alterations as described in this Lease; (v) Landlord reasonably determines that there is sufficient space in the Building for the placement of all of the provider’s equipment and materials; (vi) Landlord receives from the provider such compensation as is reasonably determined by Landlord to compensate it for the fair market value of a provider’s occupancy of the Building, and the costs which may reasonably be expected to be incurred by Landlord in conjunction with the provider’s occupancy of and activities within the Building; and (vii) all of the foregoing matters are documented in a written agreement between Landlord and the provider, the form and content of which is reasonably satisfactory to Landlord. Except as otherwise authorized in writing by Landlord, all communications services provided to Tenant shall be delivered via the Building’s CDS. Landlord may charge Tenant’s service providers fees for use of the CDS (“CDS Fees”), which includes monthly recurring fees (“Recurring CDS Fees”) for use of each circuit of the CDS used in the delivery of communications services to Tenant, and non-recurring fees (“Non-Recurring CDS Fees”) relating to activities such as moves, adds and changes of circuits which Landlord or Landlord’s agents are making. In the event that a service provider refuses for any reason to pay the CDS Fees directly to Landlord, or if Tenant is directly using the CDS to connect to a provider or otherwise, Tenant shall be responsible to pay Landlord Non-Recurring CDS Fees, but in no event shall Tenant be responsible to pay to Landlord Recurring CDS Fees, Landlord shall repair or replace the CDS as necessary to eliminate any interruption or other adverse effects to Tenant caused by malfunction, damage or destruction of the CDS, the cost of which shall be borne by Tenant if the problem was caused directly or indirectly by the act or omission of Tenant, its agents, representatives, employees or invitees. In no event shall Landlord or its agents be liable for any direct or indirect claims or damages of any kind arising out of any interruption or failure of communications or related services (including without limitation, local or long distance phone service, internet, cable TV, CDS, and data services) received by Tenant, it being understood that Tenant shall look solely to its communications services providers for recovery of any such claims or damages. To the extent that Landlord or its agents provides any communications services directly to Tenant, Tenant’s sole remedy in the event that such services provided by Landlord or its agents are interrupted or otherwise fail shall be an equitable abatement of the fees paid by Tenant to Landlord or its agents for such services, pro-rated from the date of the interruption or failure of service until the date upon which service is restored. Landlord shall have the right to designate a third party as its agent to manage and/or own the telecommunications infrastructure in the Building, whose responsibilities include without limitation management of circuit activity on the CDS (“Manager”). Manager or Landlord may provide to Tenant operating procedures for the CDS, including the phone number(s) for the, person or persons responsible for the operation and maintenance of the CDS, and Tenant agrees to comply with any such procedures. Notwithstanding the foregoing, Landlord may, in its sole discretion and upon notice to Tenant, also designate other entities as Manager of the CDS.