NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03) Radioactive Material Analysis Laboratory XXXX Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 A -61.9 0.53 - 3.01 0.021 A Gross beta 0.700 0.649 A 7.9 0.325 - 0.974 0.018 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Customer Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03FDHE01) Radioactive Material Analysis Florida Dept of Health Environmental Laboratory XXXX PO Box 680069 Orlando, FL 32868-0069 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 0.68 0.528 A -61.9 0.53 28.8 0.158 - 3.01 0.021 0.898 0.06 A Gross beta 0.700 0.649 1.13 0.937 A 7.9 0.325 20.6 0.469 - 0.974 0.018 1.406 0.06 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03TDHL01) Radioactive Material Analysis Texas Department of State Health Services Laboratory XXXX 0000 X 00xx Xxxxxx Austin, TX 78756 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 1.232 1.24 A -61.9 0.53 -0.6 0.37 - 3.01 0.021 2.11 0.031 A Gross beta 0.700 0.649 1.987 2.00 A 7.9 0.325 -0.7 1.00 - 0.974 0.018 A 3.00 0.029 N A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03TELE02) Radioactive Material Analysis Laboratory XXXX ATI Environmental, Inc., Midwest Lab 000 Xxxxxxxx Xxxx Northbrook, IL 60062- Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.30 1.77 A -61.9 -26.6 0.53 - 3.01 0.021 0.08 A Gross beta 0.700 0.81 0.649 A 7.9 24.8 0.325 - 0.974 0.018 0.04 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Customer Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03ODHL01) Radioactive Material Analysis Ohio Department of Health Laboratory XXXX 0000 X Xxxx Xxxxxx Reynoldsburg, OH 43068 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 0.538 0.528 A -61.9 0.53 1.9 0.158 - 3.01 0.021 0.898 0.035 A Gross beta 0.700 0.649 0.911 0.948 A 7.9 0.325 -3.9 0.474 - 0.974 0.018 A 1.422 0.015 N A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03SEML01) Radioactive Material Analysis SRS Environmental Monitoring Laboratory XXXX Bldg 735-B Aiken, SC 29808 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 0.405 0.528 A -61.9 0.53 -23.3 0.158 - 3.01 0.021 0.898 0.032 A Gross beta 0.700 0.649 1.07 0.948 A 7.9 0.325 12.9 0.474 - 0.974 0.018 1.422 0.028 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03SOUT01) Radioactive Material Analysis Laboratory XXXX Southwest Research Institute 0000 Xxxxxxx Xx. San Antonio, TX 78228-0510 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 0.841 1.24 A -61.9 0.53 -32.2 0.37 - 3.01 0.021 A 2.11 0.154 W Gross beta 0.700 0.649 1.92 2.00 A 7.9 0.325 -4.0 1.00 - 0.974 0.018 3.00 0.250 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03TELE01) Radioactive Material Analysis Laboratory XXXX Teledyne Brown Engineering - Environmental Services 0000 Xxxxxxx Xxxx Knoxville, TN 37931-6819 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 0.676 1.24 A -61.9 0.53 -45.5 0.37 - 3.01 0.021 2.11 0.0618 A Gross beta 0.700 0.649 2.03 2.00 A 7.9 0.325 1.5 1.00 - 0.974 0.018 3.00 0.0825 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03SOUT01) Radioactive Material Analysis Laboratory XXXX Southwest Research Institute 0000 Xxxxxxx Xx. San Antonio, TX 78228-0510 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 0.567 0.528 A -61.9 0.53 7.4 0.158 - 3.01 0.021 0.898 0.0552 A Gross beta 0.700 0.649 0.981 0.948 A 7.9 0.325 3.5 0.474 - 0.974 0.018 1.422 0.0648 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03TDHL01) Radioactive Material Analysis Texas Department of State Health Services Laboratory XXXX 0000 X 00xx Xxxxxx Austin, TX 78756 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 0.592 0.528 A -61.9 0.53 12.1 0.158 - 3.01 0.898 0.021 A Gross beta 0.700 0.649 0.923 0.915 A 7.9 0.325 0.9 0.458 - 0.974 0.018 1.373 0.020 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03GENE01) Radioactive Material Analysis Laboratory XXXX GEL Laboratories, LLC 0000 Xxxxxx Xxxx Charleston, SC 29407 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 0.531 0.528 A -61.9 0.53 0.6 0.158 - 3.01 0.021 A 0.898 0.130 W Gross beta 0.700 0.649 0.891 0.937 A 7.9 0.325 -4.9 0.469 - 0.974 0.018 1.406 0.0494 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03NARL02) Radioactive Material Analysis Laboratory USEPA - XXXXX - XXXX 000 X Xxxxxx Xxx Montgomery, AL 36115 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 0.861 1.77 A -61.9 -51.4 0.53 - 3.01 0.021 0.0720 A Gross beta 0.700 0.816 0.649 A 7.9 25.7 0.325 - 0.974 0.018 0.0620 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Customer Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03MDPH01) Radioactive Material Analysis Laboratory XXXX MDPH-Radiation Control Program XXXX-Room 000 Xxxxxxx Xxxxx, XX 00000-0000 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.283 1.77 A -61.9 -27.5 0.53 - 3.01 0.021 0.05 A Gross beta 0.700 0.734 0.649 A 7.9 13.1 0.325 - 0.974 0.018 0.04 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Customer Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03FDHE01) Radioactive Material Analysis Florida Dept of Health Environmental Laboratory XXXX PO Box 680069 Orlando, FL 32868-0069 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 0.549 0.528 A -61.9 0.53 4.0 0.158 - 3.01 0.021 0.898 0.023 A Gross beta 0.700 0.649 1.022 0.915 A 7.9 0.325 11.7 0.458 - 0.974 0.018 A 1.373 0.020 N A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03DLEA01) Radioactive Material Analysis Laboratory XXXX DLE Associates 000 Xxxxxx Xxxxx Drive Hercules, CA 94547 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 0.85 0.528 A -61.9 0.53 61.0 0.158 - 3.01 0.021 0.898 0.10 A Gross beta 0.700 0.649 0.94 0.915 A 7.9 0.325 2.7 0.458 - 0.974 0.018 1.373 0.07 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03SOUT01) Radioactive Material Analysis Laboratory XXXX Southwest Research Institute 0000 Xxxxxxx Xx. San Antonio, TX 78228-0510 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 0.448 0.528 A -61.9 0.53 -15.2 0.158 - 3.01 0.021 A 0.898 0.0937 W Gross beta 0.700 0.649 0.837 0.915 A 7.9 0.325 -8.5 0.458 - 0.974 0.018 1.373 0.122 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03HECR01) Radioactive Material Analysis SC Dept. Health and Environmental Control Radiological Laboratory XXXX 0000 Xxxxxxxx Xxxx Columbia, SC 29223 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 0.584 1.24 A -61.9 0.53 -52.9 0.37 - 3.01 0.021 2.11 0.0613 A Gross beta 0.700 0.649 2.10 2.00 A 7.9 0.325 5.0 1.00 - 0.974 0.018 3.00 0.0840 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03) Radioactive Material Analysis Laboratory XXXX ORNL Oak Ridge, TN 37830 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Value Unc Value Flag Gross alpha 0.675 1.77 A -61.9 0.53 0.131 0.528 N -75.2 0.158 - 3.01 0.021 0.898 0.011 A Gross beta 0.700 0.649 0.915 0.937 A 7.9 0.325 -2.3 0.469 - 0.974 0.018 1.406 0.054 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03CDHS01) Radioactive Material Analysis Laboratory XXXX California Department of Public Health Drinking Water & Radiation Lab. Richmond, CA 94804-6403 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 0.305 0.528 A -61.9 0.53 -42.2 0.158 - 3.01 0.021 0.898 0.0148 A Gross beta 0.700 0.649 1.001 0.937 A 7.9 0.325 6.8 0.469 - 0.974 0.018 A 1.406 0.0151 N A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03CDHS01) Radioactive Material Analysis Laboratory XXXX California Department of Public Health Drinking Water & Radiation Lab. Richmond, CA 94804-6403 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 0.319 0.528 A -61.9 0.53 -39.6 0.158 - 3.01 0.021 0.898 0.0140 A Gross beta 0.700 0.649 0.984 0.915 A 7.9 0.325 7.5 0.458 - 0.974 0.018 A 1.373 0.0150 N A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03FDHE01) Radioactive Material Analysis Florida Dept of Health Environmental Laboratory XXXX PO Box 680069 Orlando, FL 32868-0069 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 0.594 0.528 A -61.9 0.53 12.5 0.158 - 3.01 0.021 0.898 0.040 A Gross beta 0.700 0.649 0.896 0.948 A 7.9 0.325 -5.5 0.474 - 0.974 0.018 1.422 0.029 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03TELE02) Radioactive Material Analysis Laboratory XXXX ATI Environmental, Inc., Midwest Lab 000 Xxxxxxxx Xxxx Northbrook, IL 60062- Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Value Unc Value Flag Gross alpha 0.675 1.77 A -61.9 0.53 2.26 1.24 N 82.3 0.37 - 3.01 0.021 2.11 0.14 A Gross beta 0.700 0.649 2.40 2.00 A 7.9 0.325 20.0 1.00 - 0.974 0.018 3.00 0.07 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03) Radioactive Material Analysis Laboratory XXXX ORNL Oak Ridge, TN 37830 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 1.18 1.24 A -61.9 0.53 -4.8 0.37 - 3.01 0.021 2.11 0.06 A Gross beta 0.700 0.649 2.28 2.00 A 7.9 0.325 14.0 1.00 - 0.974 0.018 3.00 0.09 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03SEML01) Radioactive Material Analysis SRS Environmental Monitoring Laboratory XXXX Bldg 735-B Aiken, SC 29808 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 0.52 0.528 A -61.9 0.53 -1.5 0.158 - 3.01 0.021 0.898 0.02 A Gross beta 0.700 0.649 0.96 0.915 A 7.9 0.325 4.9 0.458 - 0.974 0.018 1.373 0.03 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03TDHL01) Radioactive Material Analysis Texas Department of State Health Services Laboratory XXXX 0000 X 00xx Xxxxxx Austin, TX 78756 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 0.357 0.528 A -61.9 0.53 -32.4 0.158 - 3.01 0.021 0.898 0.017 A Gross beta 0.700 0.649 0.990 0.948 A 7.9 0.325 4.4 0.474 - 0.974 0.018 1.422 0.021 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03WSTP99) Radioactive Material Analysis Laboratory XXXX Cavendish Nuclear Limited Xxxxxxx Xxxxx Xxxxxxx, XX XX00 0XX Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.97 1.77 A -61.9 11.3 0.53 - 3.01 0.021 0.21 A Gross beta 0.700 0.70 0.649 A 7.9 0.325 - 0.974 0.018 A 0.15 W A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Customer Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03GENE01) Radioactive Material Analysis Laboratory XXXX GEL Laboratories, LLC 0000 Xxxxxx Xxxx Xxxxxxxxxx, XX 00000 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 0.864 1.77 A -61.9 -51.2 0.53 - 3.01 0.021 0.0872 A Gross beta 0.700 0.639 0.649 A 7.9 -1.5 0.325 - 0.974 0.018 0.0414 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Customer Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03ORIS01) Radioactive Material Analysis Laboratory XXXX ORISE/IEAV PO Box 117 Oak Ridge, TN 37831-0117 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 0.335 0.528 A -61.9 0.53 -36.6 0.158 - 3.01 0.021 0.898 0.015 A Gross beta 0.700 0.649 0.943 0.937 A 7.9 0.325 0.6 0.469 - 0.974 0.018 1.406 0.020 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03TDHL01) Radioactive Material Analysis Texas Department of State Health Services Laboratory XXXX 0000 X 00xx Xxxxxx Xxxxxx, XX 00000 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.461 1.77 A -61.9 -17.5 0.53 - 3.01 0.021 0.033 A Gross beta 0.700 0.504 0.649 A 7.9 -22.3 0.325 - 0.974 0.018 0.016 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Customer Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03JLNN01) Radioactive Material Analysis Jefferson Laboratory XXXX 000 Xxxxxx Xxxxx Xxxxxxx Xxxx, XX 00000 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 0.919 1.77 A -61.9 -48.1 0.53 - 3.01 0.021 0.023 A Gross beta 0.700 0.735 0.649 A 7.9 13.3 0.325 - 0.974 0.018 0.055 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Customer Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03GENE01) Radioactive Material Analysis Laboratory XXXX GEL Laboratories, LLC 0000 Xxxxxx Xxxx Charleston, SC 29407 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 0.54 0.528 A -61.9 0.53 2.3 0.158 - 3.01 0.021 A 0.898 .109 W Gross beta 0.700 0.649 0.928 0.948 A 7.9 0.325 -2.1 0.474 - 0.974 0.018 1.422 .0491 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03URSL01) Radioactive Material Analysis UNLV Radioanalytical Services Laboratory XXXX Campus Mail Stop 453037 Las Vegas, NV 89154-3037 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 1.97 1.24 A -61.9 0.53 58.9 0.37 - 3.01 0.021 2.11 0.07 A Gross beta 0.700 0.649 1.97 2.00 A 7.9 0.325 -1.5 1.00 - 0.974 0.018 3.00 0.08 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03KSCF01) Radioactive Material Analysis Xxxxxxx Space Center, HP Laboratory XXXX IMSS-023 Xxxxxxx Space Center, FL 32899 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 0.449 1.24 A -61.9 0.53 -63.8 0.37 - 3.01 0.021 2.11 0.0190 A Gross beta 0.700 0.649 1.897 2.00 A 7.9 0.325 -5.2 1.00 - 0.974 0.018 3.00 0.0638 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03) Radioactive Material Analysis Laboratory XXXX ORNL Oak Ridge, TN 37830 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 0.318 0.528 A -61.9 0.53 -39.8 0.158 - 3.01 0.021 0.898 0.014 A Gross beta 0.700 0.649 1.045 0.915 A 7.9 0.325 14.2 0.458 - 0.974 0.018 1.373 0.023 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03FDHE01) Radioactive Material Analysis Florida Dept of Health Environmental Laboratory XXXX XX Xxx 000000 Xxxxxxx, XX 00000-0000 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 2.01 1.77 A -61.9 13.6 0.53 - 3.01 0.021 0.13 A Gross beta 0.700 0.7915 0.649 A 7.9 22.0 0.325 - 0.974 0.018 0.034 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Customer Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03SEML01) Radioactive Material Analysis SRS Environmental Monitoring Laboratory XXXX Xxxx 000-X Xxxxx, XX 00000 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.86 1.77 A -61.9 5.1 0.53 - 3.01 0.021 0.15 A Gross beta 0.700 0.70 0.649 A 7.9 0.325 - 0.974 0.018 0.03 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Customer Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03TELE02) Radioactive Material Analysis Laboratory XXXX ATI Environmental, Inc., Midwest Lab 000 Xxxxxxxx Xxxx Northbrook, IL 60062- Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 0.16 0.528 A -61.9 0.53 -69.7 0.158 - 3.01 0.021 A 0.898 0.03 W Gross beta 0.700 0.649 1.09 0.948 A 7.9 0.325 15.0 0.474 - 0.974 0.018 1.422 0.07 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03NARL02) Radioactive Material Analysis Laboratory USEPA - XXXXX - XXXX 000 X Xxxxxx Xxx Montgomery, AL 36115 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 0.169 0.528 A -61.9 0.53 -68.0 0.158 - 3.01 0.021 0.898 0.0110 A Gross beta 0.700 0.649 0.996 0.948 A 7.9 0.325 5.1 0.474 - 0.974 0.018 1.422 0.0400 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03LDRA99) Radioactive Material Analysis Laboratory XXXX Laboratori de Radiologia Ambiental-Universitat de Barcelona Facultat de Quimica Barcelona, Catalunya 08028 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 0.52 0.528 A -61.9 0.53 -1.5 0.158 - 3.01 0.021 0.898 0.04 A Gross beta 0.700 0.649 0.90 0.948 A 7.9 0.325 -5.1 0.474 - 0.974 0.018 1.422 0.04 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03URSL01) Radioactive Material Analysis UNLV Radioanalytical Services Laboratory XXXX Campus Mail Stop 453037 Las Vegas, NV 89154-3037 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 0.52 0.528 A -61.9 0.53 -1.5 0.158 - 3.01 0.021 0.898 0.03 A Gross beta 0.700 0.649 0.88 0.948 A 7.9 0.325 -7.2 0.474 - 0.974 0.018 1.422 0.04 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03ERCL01) Radioactive Material Analysis Laboratory XXXX Washington State Public Health Laboratories 0000 X.X. 150th Street Shoreline, WA 98155-9701 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 0.585 1.24 A -61.9 0.53 -52.8 0.37 - 3.01 0.021 2.11 0.045 A Gross beta 0.700 0.649 2.05 2.00 A 7.9 0.325 2.5 1.00 - 0.974 0.018 A 3.00 0.04 N A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03CMRC01) Radioactive Material Analysis Laboratory XXXX Carlsbad Environmental Monitoring and Research Center 0000 Xxxxxxxxxx Xx. Xxxxxxxx, XX 00000 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.536 1.77 A -61.9 -13.2 0.53 - 3.01 0.021 0.182 A Gross beta 0.700 0.846 0.649 A 7.9 30.4 0.325 - 0.974 0.018 0.093 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Customer Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03ORIS01) Radioactive Material Analysis Laboratory XXXX ORISE/IEAV XX Xxx 000 Xxx Xxxxx, XX 00000-0000 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 2.411 1.77 A -61.9 36.2 0.53 - 3.01 0.021 A 0.046 N Gross beta 0.700 0.766 0.649 A 7.9 18.0 0.325 - 0.974 0.018 A 0.015 N A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Customer Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03ERCL01) Radioactive Material Analysis Laboratory XXXX Washington State Public Health Laboratories 0000 X.X. 150th Street Shoreline, WA 98155-9701 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 0.633 0.528 A -61.9 0.53 19.9 0.158 - 3.01 0.021 0.898 0.047 A Gross beta 0.700 0.649 0.884 0.937 A 7.9 0.325 -5.7 0.469 - 0.974 0.018 1.406 0.023 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03WSTP99) Radioactive Material Analysis Laboratory XXXX Cavendish Nuclear Limited Xxxxxxx Court Cumbria, UK CA24 3HZ Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 0.58 0.528 A -61.9 0.53 9.8 0.158 - 3.01 0.021 A 0.898 0.11 W Gross beta 0.700 0.649 1.18 0.915 A 7.9 0.325 29.0 0.458 - 0.974 0.018 A 1.373 0.29 W A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03SEML01) Radioactive Material Analysis SRS Environmental Monitoring Laboratory XXXX Bldg 735-B Aiken, SC 29808 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 0.43 0.528 A -61.9 0.53 -18.6 0.158 - 3.01 0.021 0.898 0.035 A Gross beta 0.700 0.649 0.947 0.937 A 7.9 0.325 1.1 0.469 - 0.974 0.018 1.406 0.026 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03WSTP99) Radioactive Material Analysis Laboratory XXXX Cavendish Nuclear Limited Xxxxxxx Court Cumbria, UK CA24 3HZ Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 0.43 0.528 A -61.9 0.53 -18.6 0.158 - 3.01 0.021 A 0.898 0.08 W Gross beta 0.700 0.649 1.16 0.937 A 7.9 0.325 23.8 0.469 - 0.974 0.018 A 1.406 0.27 W A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03JLNN01) Radioactive Material Analysis Jefferson Laboratory XXXX 000 Xxxxxx Xxxxx Newport News, VA 23606 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Value Unc Value Flag Gross alpha 0.675 1.77 0.166 0.528 A -61.9 0.53 -68.6 0.158 - 3.01 0.021 0.898 0.0102 A Gross beta 0.700 0.649 A 7.9 0.325 1.39 0.915 N 51.9 0.458 - 0.974 0.018 A 1.373 0.450 N A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03NARL02) Radioactive Material Analysis Laboratory USEPA - XXXXX - XXXX 000 X Xxxxxx Xxx Montgomery, AL 36115 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 0.165 0.528 A -61.9 0.53 -68.8 0.158 - 3.01 0.021 0.898 0.0110 A Gross beta 0.700 0.649 0.961 0.937 A 7.9 0.325 2.6 0.469 - 0.974 0.018 1.406 0.0390 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03ERCL01) Radioactive Material Analysis Laboratory XXXX Washington State Public Health Laboratories 0000 X.X. 000xx Xxxxxx Xxxxxxxxx, XX 00000-0000 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 2.11 1.77 A -61.9 19.2 0.53 - 3.01 0.021 0.08 A Gross beta 0.700 0.807 0.649 A 7.9 24.3 0.325 - 0.974 0.018 0.023 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Customer Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03TDHL01) Radioactive Material Analysis Texas Department of State Health Services Laboratory XXXX 0000 X 00xx Xxxxxx Austin, TX 78756 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 0.374 0.528 A -61.9 0.53 -29.2 0.158 - 3.01 0.021 0.898 0.017 A Gross beta 0.700 0.649 0.944 0.937 A 7.9 0.325 0.7 0.469 - 0.974 0.018 1.406 0.020 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03GENE01) Radioactive Material Analysis Laboratory XXXX GEL Laboratories, LLC 0000 Xxxxxx Xxxx Charleston, SC 29407 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 0.611 0.528 A -61.9 0.53 15.7 0.158 - 3.01 0.021 A 0.898 0.129 W Gross beta 0.700 0.649 0.902 0.915 A 7.9 0.325 -1.4 0.458 - 0.974 0.018 1.373 0.0461 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03ORIS01) Radioactive Material Analysis Laboratory XXXX ORISE/IEAV PO Box 117 Oak Ridge, TN 37831-0117 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.77 1.818 1.24 A -61.9 0.53 46.6 0.37 - 3.01 0.021 2.11 0.040 A Gross beta 0.700 0.649 2.123 2.00 A 7.9 0.325 6.2 1.00 - 0.974 0.018 A 3.00 0.021 N A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Export Control Agreement
NOT ACCEPTABLE. RP<2% ACCEPTABLE. 2%<=RP<=15% ACCEPTABLE WITH WARNING. 15%<RP<=30% NOT ACCEPTABLE. RP>30% RP = Relative Precision (MART03DEHS01) Radioactive Material Analysis Laboratory XXXX Department of Environmental Health & Safety Xxxxx Xxxxxxxx Xxxxx Xxxx. Xxxxxxx, XX 00000-0000 Radiological Units: (Bq/sample) Analyte Result Ref Value Flag Notes Bias (%) Acceptance Range Unc Unc Value Flag Gross alpha 0.675 1.76 1.77 A -61.9 -0.6 0.53 - 3.01 0.021 0.06 A Gross beta 0.700 0.78 0.649 A 7.9 20.2 0.325 - 0.974 0.018 0.03 A A = Result acceptable, Bias <= +/- 70% with a statistically positive result at two standard deviations (Result/Uncertainty > 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, does not include zero). N = Result not acceptable, Bias > +/- 70% or the reported result is not statistically positive at two standard deviations (Result/Uncertainty <= 2, i.e., the range encompassing the result, plus or minus the total uncertainty at two standard deviations, includes zero).
Appears in 1 contract
Samples: Customer Export Control Agreement