Unbundled Copper Loop – Non-Designed (UCL-ND 2.4.3.1 The UCL–ND is provisioned as a dedicated 2-wire metallic transmission facility from BellSouth’s Main Distribution Frame to a customer’s premises (including the NID). The UCL-ND will be a “dry copper” facility in that it will not have any intervening equipment such as load coils, repeaters, or digital access main lines (“DAMLs”), and may have up to 6,000 feet of bridged tap between the end user’s premises and the serving wire center. The UCL-ND typically will be 1300 Ohms resistance and in most cases will not exceed 18,000 feet in length, although the UCL-ND will not have a specific length limitation. For loops less than 18,000 feet and with less than 1300 Ohms resistance, the loop will provide a voice grade transmission channel suitable for loop start signaling and the transport of analog voice grade signals. The UCL-ND will not be designed and will not be provisioned with either a DLR or a test point. 2.4.3.2 The UCL-ND facilities may be mechanically assigned using BellSouth’s assignment systems. Therefore, the Loop Make Up process is not required to order and provision the UCL-ND. However, Lightyear can request Loop Make Up for which additional charges would apply. 2.4.3.3 At an additional charge, BellSouth also will make available Loop Testing so that Lightyear may request further testing on the UCL-ND. Rates for Loop Testing are as set forth in Exhibit B of this Attachment. 2.4.3.4 UCL-ND loops are not intended to support any particular service and may be utilized by Lightyear to provide a wide-range of telecommunications services so long as those services do not adversely affect BellSouth’s network. The UCL-ND will include a Network Interface Device (NID) at the customer’s location for the purpose of connecting the loop to the customer’s inside wire. 2.4.3.5 Order Coordination (OC) will be provided as a chargeable option and may be utilized when the UCL-ND provisioning is associated with the reuse of BellSouth facilities. Order Coordination -Time Specific (OC-TS) does not apply to this product. 2.4.3.6 Lightyear may use BellSouth’s Unbundled Loop Modification (ULM) offering to remove bridge tap and/or load coils from any loop within the BellSouth network. Therefore, some loops that would not qualify as UCL-ND could be transformed into loops that do qualify, using the ULM process.
Authorization Purchase and Sale Terms of the Sponsor Warrants A. Authorization of the Sponsor Warrants. The Company has duly authorized the issuance and sale of the Sponsor Warrants to the Purchaser. B. Purchase and Sale of the Sponsor Warrants. (i) As payment in full for the 5,050,000 Sponsor Warrants being purchased under this Agreement, Purchaser shall pay $5,050,000 (the ’Purchase Price’), which amounts shall increase to 5,500,000 Sponsor Warrants for a Purchase Price of $5,500,000 if the underwriters’ over-allotment option is exercised, and in such case all references herein to Purchase Price shall instead refer to 5,500,000, by wire transfer of immediately available funds or by such other method as may be reasonably acceptable to the Company, to the trust account (the ’Trust Account’) at a financial institution to be chosen by the Company, maintained by Continental Stock Transfer & Trust Company, acting as trustee, at least one (1) business day prior to the date of effectiveness of the Registration Statement. (ii) The closing of the purchase and sale of the Sponsor Warrants shall take place simultaneously with the closing of the Public Offering (the ’Closing Date’). The closing of the purchase and sale of the Sponsor Warrants shall take place at the offices of Hxxxxx Xxxxxxx Xxxxxxx & Li LLC, 800 Xxxxx Xxx, Xxxxx 0000, Xxx Xxxx, XX 00000, or such other place as may be agreed upon by the parties hereto.
Authorization Purchase and Sale Terms of the Private Placement Warrants A. Authorization of the Private Placement Warrants. The Company has duly authorized the issuance and sale of the Private Placement Warrants to the Purchaser.
Unbundled Copper Sub-Loop (UCSL) is a copper facility of any length provided from the cross-box in the field up to and including the end-user’s point of demarcation. If available, this facility will not have any intervening equipment such as load coils between the end-user and the cross-box.
Unbundled Copper Loop – Designed (UCL-D) 2.4.2.1 The UCL-D will be provisioned as a dry copper twisted pair (2- or 4-wire) Loop that is unencumbered by any intervening equipment (e.g., filters, load coils, range extenders, digital loop carrier, or repeaters). 2.4.2.2 A UCL-D will be 18,000 feet or less in length and is provisioned according to Resistance Design parameters, may have up to 6,000 feet of bridged tap and will have up to 1300 Ohms of resistance. 2.4.2.3 The UCL-D is a designed circuit, is provisioned with a test point, and comes standard with a DLR. OC is a chargeable option for a UCL-D; however, OC is always required on UCLs where a reuse of existing facilities has been requested by Telepak Networks. 2.4.2.4 These Loops are not intended to support any particular services and may be utilized by Telepak Networks to provide a wide-range of telecommunications services as long as those services do not adversely affect BellSouth’s network. This facility will include a Network Interface Device (NID) at the customer’s location for the purpose of connecting the Loop to the customer’s inside wire. 2.4.2.5 Upon the Effective Date of this Agreement, Unbundled Copper Loop – Long (UCL-L) elements will no longer be offered by BellSouth and no new orders for UCL-L will be accepted. Any existing UCL-Ls that were provisioned prior to the Effective Date of this Agreement will be grandfathered at the rates set forth in the Parties’ interconnection agreement that was in effect immediately prior to the Effective Date of this Agreement. Existing UCL-Ls that were provisioned prior to the Effective Date of this Agreement may remain connected, maintained and repaired according to BellSouth’s TR73600 and may remain connected until such time as they are disconnected by Telepak Networks or BellSouth provides ninety
COVID-19 Vaccine Passports Pursuant to Texas Health and Safety Code, Section 161.0085(c), Contractor certifies that it does not require its customers to provide any documentation certifying the customer’s COVID-19 vaccination or post-transmission recovery on entry to, to gain access to, or to receive service from the Contractor’s business. Contractor acknowledges that such a vaccine or recovery requirement would make Contractor ineligible for a state-funded contract.
Purchase and Sale of the Sponsor Warrants (i) At least one business day prior to the consummation of the Public Offering (the “Initial Closing Date”), the Company shall issue and sell to the Purchaser, and the Purchaser shall purchase from the Company, 6,333,334 Sponsor Warrants at a price of $1.50 per warrant for an aggregate purchase price of $9,500,000 (the “Purchase Price”), which shall be paid by wire transfer of immediately available funds to the Company in accordance with the Company’s wiring instructions. On the Initial Closing Date, upon the payment by the Purchaser of the Purchase Price by wire transfer of immediately available funds to the Company, the Company, at its option, shall deliver a certificate evidencing the Sponsor Warrants purchased on such date duly registered in the Purchaser’s name to the Purchaser, or effect such delivery in book-entry form. (ii) On the date of the consummation of the closing of the over-allotment option in connection with the Public Offering or on such earlier time and date as may be mutually agreed by the Purchaser and the Company (each such date, an “Over-allotment Closing Date”, and, each Over-allotment Closing Date (if any) together with the Initial Closing Date, being sometimes referred to herein as a “Closing Date,” or the “Closing Dates”), the Company shall issue and sell to the Purchaser, and the Purchaser shall purchase from the Company, up to 750,000 Sponsor Warrants at a price of $1.50 per warrant for an aggregate purchase price of up to $1,125,000 (if the over-allotment option in connection with the Public Offering is exercised in full) (the “Over-allotment Purchase Price”), which shall be paid by wire transfer of immediately available funds to the Company in accordance with the Company’s wiring instructions. On the Over-allotment Closing Date, upon the payment by the Purchaser of the Over-allotment Purchase Price by wire transfer of immediately available funds to the Company, the Company shall, at its option, deliver a certificate evidencing the Sponsor Warrants purchased on such date duly registered in the Purchaser’s name to the Purchaser, or effect such delivery in book-entry form.
Purchases of Portfolio Shares for Sale to Customers (a) In offering and selling Portfolio shares to your customers, you agree to act as dealer for your own account; you are not authorized to act as agent for us or for any Portfolio.
Voice Grade Unbundled Copper Sub-Loop Unbundled Sub-Loop Distribution – Intrabuilding Network Cable (aka riser cable)
Unbundled Copper Loops (UCL) 2.4.1 BellSouth shall make available Unbundled Copper Loops (UCLs). The UCL is a copper twisted pair Loop that is unencumbered by any intervening equipment (e.g., filters, load coils, range extenders, digital loop carrier, or repeaters) and is not intended to support any particular telecommunications service. The UCL will be offered in two types – Designed and Non-Designed.