Ordering 7.4.1 When ordering LIS, the ordering Party shall specify requirements on the Access Service Request (ASR): 1) the type and number of Interconnection facilities to terminate at the Point of Interconnection in the Serving Wire Center; 2) the type of interoffice transport, (i.e., direct trunked transport or tandem switched transport); 3) the number of Ports to be provisioned at an End Office Switch or local Tandem Switch; and 4) any optional features. When the ordering Party requests facilities, routing, or optional features different than those determined to be available, the Parties will work cooperatively in determining an acceptable configuration, based on available facilities, equipment and routing plans. 7.4.2 For each NXX Code assigned to CLEC by the NANPA, CLEC will provide CenturyLink with the CLLI codes of the CenturyLink Tandem Switches and CLEC's Point of Interface to which traffic associated with the NXX will be routed. For NXX Codes assigned to existing LIS trunk groups, CLEC will also provide CenturyLink with the CenturyLink assigned two-six code (TGSN) to which each NXX will be routed. Information that is not currently available in the LERG may be provided via the NPA NXX Code Request Routing Form available on the CenturyLink web site: Either Party shall respond to a special request for a NPA NXX Code Request Routing Form when a single Switch is served by multiple trunk groups. 7.4.3 When either Party has ordered a DS3 Entrance Facility or private line facility, that Party will order the appropriate DS1 facility required and identify the channels of the DS3 to be used to provide connecting facility assignments (CFA). Also, if either Party has provided or ordered a DS1 Entrance Facility or private line facility, that Party will be responsible for identification of the DS0 channels of the DS1 private line to be used to provide CFA. 7.4.4 A joint planning meeting will precede initial trunking orders. These meetings will result in agreement and commitment that both Parties can implement the proposed plan and the transmittal of Access Service Requests (ASRs) to initiate order activity. The Parties will provide their best estimate of the traffic distribution to each End Office Switch subtending the Tandem Switch. 7.4.5 If CLEC uses a method of interconnection of one POI in the LATA or the access tandem for local traffic in accordance with Section 7.1.2 and/or 7.2.2.9.6, CenturyLink and CLEC will work together to review CLEC’s network configuration in order to ensure correct and complete ASR ordering. 7.4.6 Service intervals and Due Dates for initial establishment of trunking arrangements at each new Switch location of Interconnection between the Parties will be determined on an Individual Case Basis. 7.4.7 CenturyLink will establish intervals for the provision of LIS trunks that conform to the performance objectives set forth in Section 20. CenturyLink will provide notice to CLEC of any changes to the LIS trunk intervals consistent with the Change Management Process (CMP) applicable to the PCAT. Operational processes within CenturyLink work centers are discussed as part of the CMP. CenturyLink agrees that CLEC shall not be held to the requirements of the PCAT. 7.4.8 The ordering Party may cancel an order at any time prior to notification that service is available. If the ordering Party is unable to accept service within thirty (30) Days after the Service Date, the provider has the following options:
Project Initiation i - Upon final execution of the Agreement with the DISTRICT, the ARCHITECT shall: ♦ Review the Program Management Plan (PMP) with the DISTRICT and its representatives to familiarize them with the proposed tasks and schedule and develop necessary modifications. The PMP defines the Program Master Schedule and Budgets and each Project scope and budget. ii - Within the first week following execution of the Agreement, meet with the DISTRICT and its representatives to prepare a detailed task analysis and work plan for documentation in a computer-generated project schedule. iii - This task analysis and work plan will identify specific tasks including, but not limited to: ♦ interviews, ♦ data collection ♦ analysis, ♦ report preparation, ♦ planning, ♦ Architectural programming, concepts and schematic design preparation and estimating that are part of the work of the Project. Also identified will be milestone activities or dates, specific task responsibilities, required completion times necessary for the review and approval by the DISTRICT and by all regulatory agencies and additional definition of deliverables. iv - Participate in a general Project kick-off meeting to include the ARCHITECT, appropriate sub-consultants, and DISTRICT staff. v - The project kick-off meeting will introduce key team members from the DISTRICT and the ARCHITECT to each other, defining roles and responsibilities relative to the Project. vi - Identify and review pertinent information and/or documentation necessary from the DISTRICT for the completion of the Project. vii - Review and explain the overall project goals, general approach, tasks, work plan and procedures and deliverable products of the Project. viii - Review and explain the task analysis and Project work plan for all parties present; determine any adjustments or fine tuning that needs to be made to the work plan. ix - Review documentation of the Project kick-off meeting prepared by the DISTRICT’S representative and comment prior to distribution. x - Base Drawings and Site Survey Information
Initiation (i) Seller shall deliver a Transaction Request or Purchase Price Increase Request, as applicable, to Buyer on or prior to the date and time set forth in Section 4(b)(vii) prior to entering into any Transaction. Such Transaction Request or Purchase Price Increase Request shall include an Asset Schedule with respect to the Underlying Assets to be sold in such requested Transaction. Buyer shall confirm the terms of each Transaction by issuing a written confirmation to the Seller promptly after the parties enter into such Transaction in the form of Exhibit A attached hereto (a “Confirmation”). Such Confirmation shall set forth (A) the Purchase Date, (B) the Purchase Price, (C) the Repurchase/Release Date, (D) the Pricing Rate applicable to the Transaction, (E) the applicable Purchase Price Percentages, and (F) additional terms or conditions not inconsistent with this Agreement. Seller shall execute and return the Confirmation to Buyer via facsimile or electronic mail on or prior to 5:00 p.m. (New York time) on the date one (1) Business Day prior to the related Purchase Date. (ii) The Repurchase/Release Date for each Transaction shall not be later than the Termination Date. (iii) Each Confirmation, together with this Agreement, shall be conclusive evidence of the terms of the Transaction(s) covered thereby. (iv) Subject to the terms and conditions of this Agreement, during such period Seller may sell, repurchase and resell Purchased Assets, Pledged Assets, Underlying Assets and Eligible Assets hereunder. (v) No later than the date and time set forth in the Custodial Agreement, Seller shall deliver to the Custodian the Asset File pertaining to each Eligible Asset to be purchased by Buyer. (vi) Upon Buyer’s receipt of the Trust Receipt in accordance with the Custodial Agreement and subject to the provisions of this Section 4, the Purchase Price may then be made available to Seller by Buyer transferring, via wire transfer to the account designated by the Seller, in the aggregate amount of such Purchase Price in funds immediately available.
Ordering Process 6.4.1 CLEC, or CLEC's agent, shall act as the single point of contact for its End User Customers' service needs, including without limitation, sales, service design, order taking, Provisioning, change orders, training, maintenance, trouble reports, repair, post-sale servicing, Billing, collection and inquiry. CLEC's End User Customers contacting Qwest in error will be instructed to contact CLEC; and Qwest's End User Customers contacting CLEC in error will be instructed to contact Qwest. In responding to calls, neither Party shall make disparaging remarks about each other. To the extent the correct provider can be determined, misdirected calls received by either Party will be referred to the proper provider of local Exchange Service; however, nothing in this Agreement shall be deemed to prohibit Qwest or CLEC from discussing its products and services with CLEC's or Qwest's End User Customers who call the other Party seeking such information. 6.4.2 CLEC shall transmit to Qwest all information necessary for the ordering (Billing, Directory Listing and other information), installation, repair, maintenance and post-installation servicing according to Qwest's standard procedures, as described in the Qwest Product Catalog (PCAT) available on Qwest's public web site located at xxxx://xxx.xxxxx.xxx/wholesale/pcat. Information shall be provided using Qwest's designated Local Service Request (LSR) format which may include the LSR, End User Customer and resale forms. 6.4.3 Qwest will use the same performance standards and criteria for installation, Provisioning, maintenance, and repair of services provided to CLEC for resale under this Agreement as Qwest provides to itself, its Affiliates, its subsidiaries, other Resellers, and Qwest retail End User Customers. The installation, Provisioning, maintenance, and repair processes for CLEC's resale service requests are detailed in the Access to OSS Section of this Agreement, and are applicable whether CLEC's resale service requests are submitted via Operational Support System or by facsimile. 6.4.4 CLEC is responsible for providing to Qwest complete and accurate End User Customer Directory Listing information including initial and updated information for Directory Assistance Service, white pages directories, and E911/911 Emergency Services. The Ancillary Services Section of this Agreement contains complete terms and conditions for Directory Listings for Directory Assistance Services, white pages directories, and E911/911 Emergency Services. 6.4.5 If Qwest's retail End User Customer, or the End User Customer's New Service Provider orders the discontinuance of the End User Customer's existing Qwest service in anticipation of the End User Customer moving to a New Service Provider, Qwest will render its closing xxxx to the End User Customer, discontinuing Billing as of the date of the discontinuance of Qwest's service to the End User Customer. If the Current Service Provider, or if the End User Customer's New Service Provider orders the discontinuance of existing resold service from the Current Service Provider, Qwest will xxxx the Current Service Provider for service through the date the End User Customer receives resold service from the Current Service Provider. Qwest will notify CLEC by Operational Support System interface, facsimile, or by other agreed-upon processes when an End User Customer moves from the Current Service Provider to a New Service Provider. Qwest will not provide the Current Service Provider with the name of the New Service Provider selected by the End User Customer. 6.4.6 CLEC shall provide Qwest and Qwest shall provide CLEC with points of contact for order entry, problem resolution and repair of the resold services. These points of contact will be identified for both CLEC and Qwest in the event special attention is required on a service request. 6.4.7 Prior to placing orders on behalf of the End User Customer, CLEC shall be responsible for obtaining and having in its possession Proof of Authorization (POA), as set forth in the POA Section of this Agreement. 6.4.8 Due Date intervals for CLEC's resale service requests are established when service requests are received by Qwest through Operational Support Systems or by facsimile. Intervals provided to CLEC shall be equivalent to intervals provided by Qwest to itself, its Affiliates, its subsidiaries, other Resellers, and to Qwest's retail End User Customers.
Pre-Ordering 2.2.1 BellSouth will provide electronic access to its OSS and the information contained therein in order that OneTone can perform the following pre-ordering functions: service address validation, telephone number selection, service and feature availability, due date information, customer record information and loop makeup information. Mechanized access is provided by electronic interfaces whose specifications for access and use are set forth at BellSouth’s Interconnection Web site. The process by which BellSouth and OneTone will manage these electronic interfaces to include the development and introduction of new interfaces will be governed by the change management process as described in Section 2.7 below. OneTone shall provide to BellSouth access to customer record information, Version: 2Q05 Resale Agreement 07/21/05 including circuit numbers associated with each telephone number where applicable. OneTone shall provide such information within four (4) hours after request via electronic access where available. If electronic access is not available, OneTone shall provide to BellSouth paper copies of customer record information, including circuit numbers associated with each telephone number where applicable. If BellSouth requests the information before noon, the customer record information shall be provided the same day. If BellSouth requests the information after noon, the customer record information shall be provided by noon the following day. 2.2.2 The Parties agree not to view, copy, or otherwise obtain access to the customer record information of any customer without that customer's permission. OneTone will obtain access to customer record information only in strict compliance with applicable laws, rules, or regulations of the state in which the service is provided. BellSouth reserves the right to audit OneTone’s access to customer record information. If a BellSouth audit of OneTone’s access to customer record information reveals that OneTone is accessing customer record information without having obtained the proper End User authorization, BellSouth upon reasonable notice to OneTone may take corrective action, including but not limited to suspending or terminating OneTone’s electronic access to BellSouth’s OSS functionality. All such information obtained through an audit shall be deemed Information covered by Section 7, Proprietary and Confidential Information in General Terms and Conditions.
ORDERING PROCEDURE Orders placed against this contract may be in the form of an agency issued purchase order on an as-required basis. Or an agency may also use the Arkansas State Purchasing Card (P- Card) to purchase furniture.
Ordering Services a) By submitting an Order to Megaport: 1. Customer warrants that the information Customer provides to Megaport in an Order is true and correct and that Megaport may rely upon it; and 2. Customer is making a binding offer to acquire the Services described in the Order on the terms set out in this Agreement, which Megaport may accept at its discretion. An agreement to supply a Service is formed on the date Megaport provisions that Service and charges apply from the Billing Commencement Date.
Forecasting Manager and Sprint PCS will work cooperatively to generate mutually acceptable forecasts of important business metrics including traffic volumes, handset sales, subscribers and Collected Revenues for the Sprint PCS Products and Services. The forecasts are for planning purposes only and do not constitute Manager's obligation to meet the quantities forecast.
Approval Process Tenant shall notify Landlord whether it approves of the submitted working drawings within three business days after Landlord’s submission thereof. If Tenant disapproves of such working drawings, then Tenant shall notify Landlord thereof specifying in reasonable detail the reasons for such disapproval, in which case Landlord shall, within five business days after such notice, revise such working drawings in accordance with Tenant’s objections and submit the revised working drawings to Tenant for its review and approval. Tenant shall notify Landlord in writing whether it approves of the resubmitted working drawings within one business day after its receipt thereof. This process shall be repeated until the working drawings have been finally approved by Landlord and Tenant. If Tenant fails to notify Landlord that it disapproves of the initial working drawings within three business days (or, in the case of resubmitted working drawings, within one business day) after the submission thereof, then Tenant shall be deemed to have approved the working drawings in question. Any delay caused by Tenant’s unreasonable withholding of its consent or delay in giving its written approval as to such working drawings shall constitute a Tenant Delay Day (defined below). If the working drawings are not fully approved (or deemed approved) by both Landlord and Tenant by the 15th business day after the delivery of the initial draft thereof to Tenant, then each day after such time period that such working drawings are not fully approved (or deemed approved) by both Landlord and Tenant shall constitute a Tenant Delay Day.
Validation To validate the notice requirements outlined in Section 5.3, the Assuming Institution shall provide the Receiver (i) an Affidavit of Publication to meet the publication requirements outlined in Section 5.3(a) and (ii) the Assuming Institution will prepare an Affidavit of Mailing in a form substantially similar to Exhibit 2.3B after mailing the seven (7) day Notice to Depositors as required under Section 5.3(b).