Patient Positioning System Sample Clauses

Patient Positioning System. The Patient Positioning System is the component of the PERFEXION™ system that the patient reclines on for treatment and is positioned relative the point of focus in the radiation unit. The following section describes selected components within the Patient Positioning System. All components are chosen from well-recognized suppliers to secure reliability and to optimize the performance of Leksell Gamma Knife PERFEXION. Couch framework with X/Y/Z drive Framework 20 mm zinc chromated steel Motors DC motors with 2000 line encoders. Gear X/Y-axis Planetary gear 30:1 Z-axis Planetary gear 4:1 Ball screws Bearing houses Support bearings X/Z -axis. Screw jxxx Y-axis: Integrated safety nut. Linear guides Linear guide blocks Caged ball technology. Solenoid Y-axis: Photo-micro sensor. Linear encoders Absolute Linear encoders. Accuracy grade +/- 0.005mm. Servo Controllers High precision, fully digital servo drive, with embedded intelligence. Frame fixation Hardened stainless steel Comfort system Mattress support Sandwich structure with aluminum honeycomb core and steel sheets Actuator DC actuator Ball bearing Stainless steel.
AutoNDA by SimpleDocs

Related to Patient Positioning System

  • Review Systems; Personnel It will maintain business process management and/or other systems necessary to ensure that it can perform each Test and, on execution of this Agreement, will load each Test into these systems. The Asset Representations Reviewer will ensure that these systems allow for each Review Receivable and the related Review Materials to be individually tracked and stored as contemplated by this Agreement. The Asset Representations Reviewer will maintain adequate staff that is properly trained to conduct Reviews as required by this Agreement.

  • Metering The Interconnection Customer shall be responsible for the Connecting Transmission Owner’s reasonable and necessary cost for the purchase, installation, operation, maintenance, testing, repair, and replacement of metering and data acquisition equipment specified in Attachments 2 and 3 of this Agreement. The Interconnection Customer’s metering (and data acquisition, as required) equipment shall conform to applicable industry rules and Operating Requirements.

  • Infrastructure (a) The Borrower has and will maintain a sufficient infrastructure to conduct its business as presently conducted and as contemplated to be conducted following its execution of this Agreement.

  • Monitoring System In each case in which the Custodian has exercised delegated authority to place Assets with a Foreign Custodian, the Custodian shall establish a system, to re-assess or re-evaluate selected Foreign Custodians, at least annually in accordance with Rule 17f-5(c)(3).

  • Service Locations X.X. Xxxxxx maintains various operational/service centers and locations through the United States and foreign jurisdictions. The services provided under this Agreement may be provided from one or more such locations. X.X. Xxxxxx may change the operational/service centers and locations as it deems necessary or appropriate for its business concerns.

  • Temperature Where low temperature and/or self-service cases are used for any of such merchandise coming under the jurisdiction of the Union, such cases shall be served only by employees covered by this Agreement.

  • Building Systems The term “Building Systems” shall mean collectively the mechanical, electrical, plumbing, sanitary, sprinkler, heating, ventilation and air conditioning, security, life safety, elevator and other service systems or facilities of the Building and the finished ceiling and Building standard lighting fixtures in the Leased Premises, that are excluding any Premises Fixtures.

  • Utility Services Company agrees to pay the full cost and expense associated with its use of all utilities, including but not limited to water, sanitary sewer, electric, storm drainage, and telecommunication services.

Time is Money Join Law Insider Premium to draft better contracts faster.