Common use of Physical File Characteristics Clause in Contracts

Physical File Characteristics. 6.2.1 The Optional Daily Usage File will be distributed to Lightyear via an agreed medium with CONNECT:Direct being the preferred transport method. The ODUF feed will be a variable block format (2476) with an LRECL of 2472. The data on the ODUF feed will be in a non-compacted EMI format (175 byte format plus modules). It will be created on a daily basis (Monday through Friday except holidays). Details such as dataset name and delivery schedule will be addressed during negotiations of the distribution medium. There will be a maximum of one dataset per workday per OCN. 6.2.2 Data circuits (private line or dial-up) will be required between BellSouth and Lightyear for the purpose of data transmission. Where a dedicated line is required, Lightyear will be responsible for ordering the circuit, overseeing its installation and coordinating the installation with BellSouth. Lightyear will also be responsible for any charges associated with this line. Equipment required on the BellSouth end to attach the line to the mainframe computer and to transmit successfully ongoing will be negotiated on an individual case basis. Where a dial-up facility is required, dial circuits will be installed in the BellSouth data center by BellSouth and the associated charges assessed to Lightyear. Additionally, all message toll charges associated with the use of the dial circuit by Lightyear will be the responsibility of Lightyear. Associated equipment on the BellSouth end, including a modem, will be negotiated on an individual case basis between the Parties. All equipment, including modems and software, that is required on Lightyear end for the purpose of data transmission will be the responsibility of Lightyear.

Appears in 3 contracts

Samples: Clec Agreement, Clec Agreement, Clec Agreement

AutoNDA by SimpleDocs

Physical File Characteristics. 6.2.1 The Optional Daily Usage File will be distributed to Lightyear Starlink via an agreed medium with CONNECT:Direct being the preferred transport method. The ODUF feed will be a variable block format (2476) with an LRECL of 2472. The data on the ODUF feed will be in a non-compacted EMI format (175 byte format plus modules). It will be created on a daily basis (Monday through Friday except holidays). Details such as dataset name and delivery schedule will be addressed during negotiations of the distribution medium. There will be a maximum of one dataset per workday per OCN. 6.2.2 Data circuits (private line or dial-up) will be required between BellSouth and Lightyear Starlink for the purpose of data transmission. Where a dedicated line is required, Lightyear Starlink will be responsible for ordering the circuit, overseeing its installation and coordinating the installation with BellSouth. Lightyear Starlink will also be responsible for any charges associated with this line. Equipment required on the BellSouth end to attach the line to the mainframe computer and to transmit successfully ongoing will be negotiated on an individual case basis. Where a dial-up facility is required, dial circuits will be installed in the BellSouth data center by BellSouth and the associated charges assessed to LightyearStarlink . Additionally, all message toll charges associated with the use of the dial circuit by Lightyear Starlink will be the responsibility of LightyearStarlink . Associated equipment on the BellSouth end, including a modem, will be negotiated on an individual case basis between the Parties. All equipment, including modems and software, that is required on Lightyear Starlink end for the purpose of data transmission will be the responsibility of LightyearStarlink .

Appears in 1 contract

Samples: Clec Agreement

Physical File Characteristics. 6.2.1 The Optional Daily Usage File will be distributed to Lightyear Local Line via an agreed medium with CONNECT:Direct being the preferred transport method. The ODUF feed will be a variable block format (2476) with an LRECL of 2472. The data on the ODUF feed will be in a non-compacted EMI format (175 byte format plus modules). It will be created on a daily basis (Monday through Friday except holidays). Details such as dataset name and delivery schedule will be addressed during negotiations of the distribution medium. There will be a maximum of one dataset per workday per OCN. 6.2.2 Data circuits (private line or dial-up) will be required between BellSouth and Lightyear Local Line for the purpose of data transmission. Where a dedicated line is required, Lightyear Local Line will be responsible for ordering the circuit, overseeing its installation and coordinating the installation with BellSouth. Lightyear Local Line will also be responsible for any charges associated with this line. Equipment required on the BellSouth end to attach the line to the mainframe computer and to transmit successfully ongoing will be negotiated on an individual case basis. Where a dial-up facility is required, dial circuits will be installed in the BellSouth data center by BellSouth and the associated charges assessed to LightyearLocal Line. Additionally, all message toll charges associated with the use of the dial circuit by Lightyear Local Line will be the responsibility of LightyearLocal Line. Associated equipment on the BellSouth end, including a modem, will be negotiated on an individual case basis between the Parties. All equipment, including modems and software, that is required on Lightyear Local Line end for the purpose of data transmission will be the responsibility of LightyearLocal Line.

Appears in 1 contract

Samples: Clec Agreement

Physical File Characteristics. 6.2.1 The Optional Daily Usage File will be distributed to Lightyear Navigator via an agreed medium with CONNECT:Direct being the preferred transport method. The ODUF feed will be a variable block format (2476) with an LRECL of 2472. The data on the ODUF feed will be in a non-compacted EMI format (175 byte format plus modules). It will be created on a daily basis (Monday through Friday except holidays). Details such as dataset name and delivery schedule will be addressed during negotiations of the distribution medium. There will be a maximum of one dataset per workday per OCN. 6.2.2 Data circuits (private line or dial-up) will be required between BellSouth and Lightyear Navigator for the purpose of data transmission. Where a dedicated line is required, Lightyear Navigator will be responsible for ordering the circuit, overseeing its installation and coordinating the installation with BellSouth. Lightyear Navigator will also be responsible for any charges associated with this line. Equipment required on the BellSouth end to attach the line to the mainframe computer and to transmit successfully ongoing will be negotiated on an individual case basis. Where a dial-up facility is required, dial circuits will be installed in the BellSouth data center by BellSouth and the associated charges assessed to LightyearNavigator. Additionally, all message toll charges associated with the use of the dial circuit by Lightyear Navigator will be the responsibility of LightyearNavigator. Associated equipment on the BellSouth end, including a modem, will be negotiated on an individual case basis between the Parties. All equipment, including modems and software, that is required on Lightyear Navigator end for the purpose of data transmission will be the responsibility of LightyearNavigator.

Appears in 1 contract

Samples: Telecommunications

Physical File Characteristics. 6.2.1 The Optional Daily Usage File will be distributed to Lightyear ACI via an agreed medium with CONNECT:Direct being the preferred transport method. The ODUF feed will be a variable block format (2476) with an LRECL of 2472. The data on the ODUF feed will be in a non-compacted EMI format (175 byte format plus modules). It will be created on a daily basis (Monday through Friday except holidays). Details such as dataset name and delivery schedule will be addressed during negotiations of the distribution medium. There will be a maximum of one dataset per workday per OCN. 6.2.2 Data circuits (private line or dial-up) will be required between BellSouth and Lightyear ACI for the purpose of data transmission. Where a dedicated line is required, Lightyear ACI will be responsible for ordering the circuit, overseeing its installation and coordinating the installation with BellSouth. Lightyear ACI will also be responsible for any charges associated with this line. Equipment required on the BellSouth end to attach the line to the mainframe computer and to transmit successfully ongoing will be negotiated on an individual case basis. Where a dial-up facility is required, dial circuits will be installed in the BellSouth data center by BellSouth and the associated charges assessed to LightyearACI. Additionally, all message toll charges associated with the use of the dial circuit by Lightyear ACI will be the responsibility of LightyearACI. Associated equipment on the BellSouth end, including a modem, will be negotiated on an individual case basis between the Parties. All equipment, including modems and software, that is required on Lightyear ACI end for the purpose of data transmission will be the responsibility of LightyearACI.

Appears in 1 contract

Samples: Clec Agreement

AutoNDA by SimpleDocs

Physical File Characteristics. 6.2.1 The Optional Daily Usage File will be distributed to Lightyear BasicPhone via an agreed medium with CONNECT:Direct being the preferred transport method. The ODUF feed will be a variable block format (2476) with an LRECL of 2472. The data on the ODUF feed will be in a non-compacted EMI format (175 byte format plus modules). It will be created on a daily basis (Monday through Friday except holidays). Details such as dataset name and delivery schedule will be addressed during negotiations of the distribution medium. There will be a maximum of one dataset per workday per OCN. 6.2.2 Data circuits (private line or dial-up) will be required between BellSouth and Lightyear BasicPhone for the purpose of data transmission. Where a dedicated line is required, Lightyear BasicPhone will be responsible for ordering the circuit, overseeing its installation and coordinating the installation with BellSouth. Lightyear BasicPhone will also be responsible for any charges associated with this line. Equipment required on the BellSouth end to attach the line to the mainframe computer and to transmit successfully ongoing will be negotiated on an individual case basis. Where a dial-up facility is required, dial circuits will be installed in the BellSouth data center by BellSouth and the associated charges assessed to LightyearBasicPhone. Additionally, all message toll charges associated with the use of the dial circuit by Lightyear BasicPhone will be the responsibility of LightyearBasicPhone. Associated equipment on the BellSouth end, including a modem, will be negotiated on an individual case basis between the Parties. All equipment, including modems and software, that is required on Lightyear BasicPhone end for the purpose of data transmission will be the responsibility of LightyearBasicPhone.

Appears in 1 contract

Samples: Clec Agreement

Physical File Characteristics. 6.2.1 The Optional Daily Usage File will be distributed to Lightyear Actel via an agreed medium with CONNECT:Direct being the preferred transport method. The ODUF feed will be a variable block format (2476) with an LRECL of 2472. The data on the ODUF feed will be in a non-compacted EMI format (175 byte format plus modules). It will be created on a daily basis (Monday through Friday except holidays). Details such as dataset name and delivery schedule will be addressed during negotiations of the distribution medium. There will be a maximum of one dataset per workday per OCN. 6.2.2 Data circuits (private line or dial-up) will be required between BellSouth and Lightyear Actel for the purpose of data transmission. Where a dedicated line is required, Lightyear Actel will be responsible for ordering the circuit, overseeing its installation and coordinating the installation with BellSouth. Lightyear Actel will also be responsible for any charges associated with this line. Equipment required on the BellSouth end to attach the line to the mainframe computer and to transmit successfully ongoing will be negotiated on an individual case basis. Where a dial-up facility is required, dial circuits will be installed in the BellSouth data center by BellSouth and the associated charges assessed to LightyearActel. Additionally, all message toll charges associated with the use of the dial circuit by Lightyear Actel will be the responsibility of LightyearActel. Associated equipment on the BellSouth end, including a modem, will be negotiated on an individual case basis between the Parties. All equipment, including modems and software, that is required on Lightyear Actel end for the purpose of data transmission will be the responsibility of LightyearActel.

Appears in 1 contract

Samples: Interconnection Agreement

Physical File Characteristics. 6.2.1 The Optional Daily Usage File ODUF will be distributed to Lightyear via an agreed medium with CONNECT:Direct being the preferred transport method. The ODUF feed Daily Usage Feed will be a variable block format (2476) with an LRECL of 2472. The data on the ODUF feed Daily Usage Feed will be in a non-compacted EMI format (175 byte format plus modules). It will be created on a daily basis (Monday through Friday except holidays). Details such as dataset name and delivery schedule will be addressed during negotiations of the distribution medium. There will be a maximum of one dataset per workday per OCN. 6.2.2 Data circuits (private line or dial-up) will may be required between BellSouth and Lightyear for the purpose of data transmission. Where a dedicated line is required, Lightyear will be responsible for ordering the circuit, overseeing its installation and coordinating the installation with BellSouth. Lightyear Xxxxxxxxx will also be responsible for any charges associated with this line. Equipment required on the BellSouth end to attach the line to the mainframe computer and to transmit successfully ongoing will be negotiated on an individual a case by case basis. Where a dial-up facility is required, dial circuits will be installed in the BellSouth data center by BellSouth and the associated charges assessed to Lightyear. Additionally, all message toll charges associated with the use of the dial circuit by Lightyear will be the responsibility of Lightyear. Associated equipment on the BellSouth end, including a modem, will be negotiated on an individual a case by case basis between the Partiesparties. All equipment, including modems and software, that is required on Lightyear Lightyear’s end for the purpose of data transmission will be the responsibility of Lightyear.

Appears in 1 contract

Samples: Terms and Conditions Agreement

Draft better contracts in just 5 minutes Get the weekly Law Insider newsletter packed with expert videos, webinars, ebooks, and more!