Plug-In Sample Clauses

Plug-In. Effective with the March 2006 pick, Rail Operators will be required to report fifteen (15) minutes before their LRV is scheduled to pull-out of the garage and shall be paid for such time. If an operator is required to work a relief, the Operator will be paid twelve (12) minutes.
AutoNDA by SimpleDocs

Related to Plug-In

  • Power Factor Design Criteria (Reactive Power A wind generating plant shall maintain a power factor within the range of 0.95 leading to 0.95 lagging, measured at the Point of Interconnection as defined in this LGIA, if the ISO’s System Reliability Impact Study shows that such a requirement is necessary to ensure safety or reliability. The power factor range standards can be met using, for example without limitation, power electronics designed to supply this level of reactive capability (taking into account any limitations due to voltage level, real power output, etc.) or fixed and switched capacitors if agreed to by the Connecting Transmission Owner for the Transmission District to which the wind generating plant will be interconnected, or a combination of the two. The Developer shall not disable power factor equipment while the wind plant is in operation. Wind plants shall also be able to provide sufficient dynamic voltage support in lieu of the power system stabilizer and automatic voltage regulation at the generator excitation system if the System Reliability Impact Study shows this to be required for system safety or reliability.

  • Loop Provisioning Involving IDLC 2.16.1 Where TWTC has requested an Unbundled Loop and AT&T uses IDLC systems to provide the local service to the customer and AT&T has a suitable alternate facility available, AT&T will make such alternative facilities available to TWTC. If a suitable alternative facility is not available, then to the extent it is technically feasible, AT&T will implement one of the following alternative arrangements for TWTC (e.g., hairpinning):

  • Drug and Alcohol Testing Permitted Testing is permitted where the Employer has reasonable suspicion to believe.

  • Reactive Power 1.8.1 The Interconnection Customer shall design its Small Generating Facility to maintain a composite power delivery at continuous rated power output at the Point of Interconnection at a power factor within the range established by the Connecting Transmission Owner on a comparable basis, until NYISO has established different requirements that apply to all similarly situated generators in the New York Control Area on a comparable basis.

  • Payment for Reactive Power NYISO shall pay Developer for reactive power or voltage support service that Developer provides from the Large Generating Facility in accordance with the provisions of Rate Schedule 2 of the NYISO Services Tariff.

  • ROAD GRADE AND ALIGNMENT STANDARDS Purchaser shall follow these standards for road grade and alignment except as designed:  Grade and alignment must have smooth continuity, without abrupt changes in direction.  Maximum grades may not exceed 18 percent favorable and 12 percent adverse.  Minimum curve radius is 60 feet at centerline.  Maximum grade change for sag vertical curves is 5% in 100 feet.  Maximum grade change for crest vertical curves is 4% in 100 feet.

  • Loop Provisioning Involving Integrated Digital Loop Carriers 2.6.1 Where InterGlobe has requested an Unbundled Loop and BellSouth uses IDLC systems to provide the local service to the End User and BellSouth has a suitable alternate facility available, BellSouth will make such alternative facilities available to InterGlobe. If a suitable alternative facility is not available, then to the extent it is technically feasible, BellSouth will implement one of the following alternative arrangements for InterGlobe (e.g. hairpinning):

  • Scope and Application This Appendix will apply to all work undertaken within the Employer’s Workshop(s) by employees mainly engaged at the Workshop.

  • Copper Subloops Sprint will make available access to copper subloops on an unbundled basis. A copper subloop is a portion of a Copper Loop, or Hybrid Loop, and is comprised entirely of copper wire or copper cable that acts as a transmission facility between any accessible terminal in Sprint’s outside plant, including inside wire owned or controlled by Sprint, and the end-user customer premises. A copper subloop can also include intermediate devices, such as repeaters, used to establish the transmission path. Copper subloops can be used by CLEC to provide voice-grade services as well as digital subscriber line services. Access to copper subloops is subject to the collocation provisions of this Agreement. Copper subloop consists of the distribution portion of the copper loop. Sprint is not obligated to offer feeder loop plant as a stand-alone UNE.

  • Consent to Emails and Automated Text Messages By participating as a User, you represent that you are the owner of the email address, mobile phone number, and/or other alias you enrolled, or that you have the delegated legal authority to act on behalf of the owner of such email address, mobile phone number and/or other alias to send or receive money as described in this Agreement. You consent to the receipt of emails or text messages from us, from Zelle, from other Users that are sending you money or requesting money from you, and from other Network Banks or their agents regarding the Services or related transfers between Network Banks and you. You agree that we may, Zelle may or either of our agents may use automatic telephone dialing systems in connection with text messages sent to any mobile phone number you enroll. You further acknowledge and agree: