Loop Provisioning Involving Integrated Digital Loop Carriers 2.6.1 Where Xxxx has requested an Unbundled Loop and BellSouth uses IDLC systems to provide the local service to the End User and BellSouth has a suitable alternate facility available, BellSouth will make such alternative facilities available to Xxxx. If a suitable alternative facility is not available, then to the extent it is technically feasible, BellSouth will implement one of the following alternative arrangements for Xxxx (e.g. hairpinning): 1. Roll the circuit(s) from the IDLC to any spare copper that exists to the customer premises. 2. Roll the circuit(s) from the IDLC to an existing DLC that is not integrated. 3. If capacity exists, provide "side-door" porting through the switch. 4. If capacity exists, provide "Digital Access Cross Connect System (DACS)- door" porting (if the IDLC routes through a DACS prior to integration into the switch). 2.6.2 Arrangements 3 and 4 above require the use of a designed circuit. Therefore, non- designed Loops such as the SL1 voice grade and UCL-ND may not be ordered in these cases. 2.6.3 If no alternate facility is available, and upon request from Xxxx, and if agreed to by both Parties, BellSouth may utilize its Special Construction (SC) process to determine the additional costs required to provision facilities. Xxxx will then have the option of paying the one-time SC rates to place the Loop.
Unbundled Digital Loops 2.3.1 BellSouth will offer Unbundled Digital Loops (UDL). UDLs are service specific, will be designed, will be provisioned with test points (where appropriate), and will come standard with OC and a DLR. The various UDLs are intended to support a specific digital transmission scheme or service. 2.3.2 BellSouth shall make available the following UDLs, subject to restrictions set forth herein:
Computer Tape The computer tape regarding the Receivables made available by the Seller to the Depositor is complete and accurate in all respects as of the Transfer Date.
Computer Equipment Recycling Program If this Contract is for the purchase or lease of computer equipment, then Contractor certifies that it is in compliance with Subchapter Y, Chapter 361 of the Texas Health and Safety Code related to the Computer Equipment Recycling Program and the Texas Commission on Environmental Quality rules in 30 TAC Chapter 328.
Wire Unbundled DS1 Digital Loop This is a designed 4-wire Loop that is provisioned according to industry standards for DS1 or Primary Rate ISDN services and will come standard with a test point, OC, and a DLR. A DS1 Loop may be provisioned over a variety of loop transmission technologies including copper, HDSL-based technology or fiber optic transport systems. It will include a 4-Wire DS1 Network Interface at the End User’s location.
BILLING ERRORS In case of errors or questions about electronic fund transfers from your share and share draft accounts or if you need more information about a transfer on the statement or receipt, telephone us at the following number or send us a written notice to the following address as soon as you can. We must hear from you no later than 60 days after we sent the FIRST statement on which the problem appears. Call us at:
Provisional Interconnection Service Upon the request of Interconnection Customer, and prior to completion of requisite Interconnection Facilities, Network Upgrades, Local Upgrades, or system protection facilities Interconnection Customer may request limited Interconnection Service at the discretion of Transmission Provider based upon an evaluation that will consider the results of available studies, which terms shall be memorialized in the Interconnection Service Agreement. Consistent with Tariff, Part VI, Subpart B, section 212.4, Interconnection Customer may execute the Interconnection Service Agreement, request dispute resolution or request that the Interconnection Service Agreement be filed unexecuted with the Commission. Transmission Provider shall determine, through available studies or additional studies as necessary, whether stability, short circuit, thermal, and/or voltage issues would arise if Interconnection Customer interconnects without modifications to the Generating Facility or the Transmission System. Transmission Provider shall determine whether any Interconnection Facilities, Network Upgrades, Local Upgrades, or system protection facilities that are necessary to meet the requirements of NERC, or any applicable Regional Entity for the interconnection of a new, modified and/or expanded Generating Facility are in place prior to the commencement of Interconnection Service from the Generating Facility. Where available studies indicate that such Interconnection Facilities, Network Upgrades, Local Upgrades, and/or system protection facilities that are required for the interconnection of a new, modified and/or expanded Generating Facility are not currently in place, Transmission Provider will perform a study, at the Interconnection Customer’s expense, to confirm the facilities that are required for Provisional Interconnection Service. The maximum permissible output of the Generating Facility shall be studied and updated annually and at the Interconnection Customer’s expense. The results will be communicated to the Interconnection Customer in writing upon completion of the study. Interconnection Customer assumes all risk and liabilities with respect to the Provisional Interconnection Service, including changes in output limits and Interconnection Facilities, Network Upgrades, Local Upgrades, and/or system protection facilities cost responsibilities.
Assets Not Purchased by Assuming Institution The Assuming Institution does not purchase, acquire or assume, or (except as otherwise expressly provided in this Agreement) obtain an option to purchase, acquire or assume under this Agreement: (a) any financial institution bonds, banker's blanket bonds, or public liability, fire, extended coverage insurance policy, bank owned life insurance or any other insurance policy of the Failed Bank, or premium refund, unearned premium derived from cancellation, or any proceeds payable with respect to any of the foregoing; (b) any interest, right, action, claim, or judgment against (i) any officer, director, employee, accountant, attorney, or any other Person employed or retained by the Failed Bank or any Subsidiary of the Failed Bank on or prior to Bank Closing arising out of any act or omission of such Person in such capacity, (ii) any underwriter of financial institution bonds, banker's blanket bonds or any other insurance policy of the Failed Bank, (iii) any shareholder or holding company of the Failed Bank, or (iv) any other Person whose action or inaction may be related to any loss (exclusive of any loss resulting from such Person's failure to pay on a Loan made by the Failed Bank) incurred by the Failed Bank; provided, that for the purposes hereof, the acts, omissions or other events giving rise to any such claim shall have occurred on or before Bank Closing, regardless of when any such claim is discovered and regardless of whether any such claim is made with respect to a financial institution bond, banker's blanket bond, or any other insurance policy of the Failed Bank in force as of Bank Closing; (c) prepaid regulatory assessments of the Failed Bank, if any; (d) legal or equitable interests in tax receivables of the Failed Bank, if any, including any claims arising as a result of the Failed Bank having entered into any agreement or otherwise being joined with another Person with respect to the filing of tax returns or the payment of taxes; (e) amounts reflected on the Accounting Records of the Failed Bank as of Bank Closing as a general or specific loss reserve or contingency account, if any; (f) leased or owned Bank Premises and leased or owned Furniture and Equipment and Fixtures and data processing equipment (including hardware and software) located on leased or owned Bank Premises, if any; provided, that the Assuming Institution does obtain an option under Section 4.6, Section 4.7 or Section 4.8, as the case may be, with respect thereto; (g) owned Bank Premises which the Receiver, in its discretion, determines may contain environmentally hazardous substances; (h) any "goodwill," as such term is defined in the instructions to the report of condition prepared by banks examined by the Corporation in accordance with 12 C.F.R. Section 304.3, and other intangibles; (i) any criminal restitution or forfeiture orders issued in favor of the Failed Bank; (j) reserved; (k) assets essential to the Receiver in accordance with Section 3.6; (l) the securities listed on the attached Schedule 3.5(l); and (m) prepaid accounts associated with any contract or agreement that the Assuming Institution either does not directly assume pursuant to the terms of this Agreement nor has an option to assume under Section 4.8.
Mail Order Catalog Warnings In the event that, the Settling Entity prints new catalogs and sells units of the Products via mail order through such catalogs to California consumers or through its customers, the Settling Entity shall provide a warning for each unit of such Product both on the label in accordance with subsection 2.4 above, and in the catalog in a manner that clearly associates the warning with the specific Product being purchased. Any warning provided in a mail order catalog shall be in the same type size or larger than other consumer information conveyed for such Product within the catalog and shall be located on the same display page of the item. The catalog warning may use the Short-Form Warning content described in subsection 2.3(b) if the language provided on the Product label also uses the Short-Form Warning.
COMPUTER GRAPHICS FILES The Engineer agrees to comply with Attachment G, Computer Graphics Files for Document and Information Exchange, if determined by the State to be applicable to this contract.