Record Drawings and Final Documents. The Design Professional shall, upon final completion of the Project, revise the Bidding Documents based upon documents incorporated by Change Orders, additional sketches, field changes, answered RFI’s issued by the Design Professional, and marked-up documents provided by the Contractor to show the Project “as built.” The Design Professional shall furnish and deliver the Record Drawings to the Owner after the entire work is completed and not later than sixty calendar days after execution of its Certificate of Final Completion. Record Drawings and Final Documents shall reflect all changes caused by addenda, field changes, Change Orders, or observed changes by the Design Professional, the Contractor, or Subcontractors. The Design Professional shall furnish the Owner, at no additional cost, three bound sets of specifications, complete with all addenda and authorized Change Orders, and the following sets of Contract Drawings: (a) One set of full-size reproducible documents; (b) Three sets of full-size blue or black line prints; and (c) Electronic media (CD-ROM including CADD) files in PDF format, Autodesk DWF format, or other electronic media approved by the Owner. Based upon additional information provided by the Contractor, the Record Drawings and Final Documents shall show the Design Professional’s understanding of the locations of all utility lines and shall be altered to conform to all changes made in the building during its construction. The Design Professional shall furnish additional copies of the aforesaid documents or reproducible documents as requested by Owner, for which the Owner shall pay the actual cost of reproduction.
Appears in 9 contracts
Samples: Design Professional Contract, Design Professional Contract, Design Professional Contract
Record Drawings and Final Documents. The Design Professional shall, upon final completion of the Project, revise the Bidding Documents based upon documents incorporated by Change Orders, additional sketches, field changes, answered RFI’s issued by the Design Professional, and marked-up documents provided by the Contractor to show the Project “as built.” The Design Professional shall furnish and deliver the Record Drawings to the Owner after the entire work is completed and not later than sixty calendar days after execution of its Certificate of Final Completion. Record Drawings and Final Documents shall reflect all changes caused by addenda, field changes, Change Orders, or observed changes by the Design Professional, the Contractor, or Subcontractors. The Design Professional shall furnish the Owner, at no additional cost, three two (2) bound sets of specifications, complete with all addenda and authorized Change Orders, and the following sets of Contract Drawings:
(a) One (1) set of full-size reproducible documentsand two (2) one half (1/2) blue or black line prints;
(b) Three sets One (1) set of full-size blue or black line prints; and
(c) Electronic electronic media (CD-ROM including CADD) files in PDF format, Autodesk DWF DWG format, or other electronic media approved by the Owner. Based upon additional information provided by the Contractor, the Record Drawings and Final Documents shall show the Design Professional’s understanding of the locations of all utility lines and shall be altered to conform to all changes made in the building during its construction. The Design Professional shall furnish additional copies of the aforesaid documents or reproducible documents as requested by Owner, for which the Owner shall pay the actual cost of reproduction.
Appears in 7 contracts
Samples: Design Professional Contract, Design Professional Contract, Design Professional Contract
Record Drawings and Final Documents. The Design Professional shall, upon final completion of the Project, revise the Bidding Documents original drawings and specifications based upon documents incorporated by Change Orders, additional sketches, field changes, answered RFI’s issued by the Design Professional, and marked-marked up documents provided by the Contractor CM/GC to show the Project project “as built.” ”. The Design Professional shall furnish and deliver the Record Drawings to the Owner after the entire work is completed completed, and not later than sixty (60) calendar days after execution of its Certificate of Final Completion, the Record Drawings. (Record Drawings and Final Documents shall reflect all changes caused by addenda, field changes, Change Orders, change orders or observed changes by the Design Professional, the Contractor, CM/GC or Subcontractorsthe subcontractor(s) to the extend such CM/GC or Subcontractor observations are communicated in writing to the Design Professional. The Design Professional shall furnish the Owner, at no additional cost, three bound sets of specifications, complete with all addenda and authorized Change Orders, Orders and the following sets of Contract Drawings:
(a) : One set of full-size reproducible documents;
(b) , Three sets of full-size blue or black line prints; and
(c) , and Electronic media (CD-ROM including CADD) files in PDF format, Autodesk DWF format, Format or Autoview Format or AutoCAD) or other electronic media approved by the Owner. equal Based upon additional information provided by the ContractorCM/GC, the Record Drawings and Final Documents shall show the Design Professional’s understanding of the locations of all utility lines and shall be altered to conform to all changes made in the building during its construction. The Design Professional shall furnish additional copies of the aforesaid documents or reproducible documents as requested by Owner, for which the Owner shall pay the actual cost of reproduction.
Appears in 7 contracts
Samples: Design Professional Services Contract, Design Professional Services Contract, Design Professional Services Contract
Record Drawings and Final Documents. The Design Professional shall, upon final completion of the Project, revise the Bidding Documents original drawings and specifications based upon documents incorporated by Change Orders, additional sketches, field changes, answered RFI’s issued by the Design Professional, and marked-marked up documents provided by the Contractor CM/GC to show the Project project “as built.” ”. The Design Professional shall furnish and deliver the Record Drawings to the Owner after the entire work is completed completed, and not later than sixty (60) calendar days after execution of its Certificate of Final Completion, the Record Drawings. (Record Drawings and Final Documents shall reflect all changes caused by addenda, field changes, Change Orders, change orders or observed changes by the Design Professional, the Contractor, CM/GC or Subcontractorsthe subcontractor(s) to the extend such CM/GC or Subcontractor observations are communicated in writing to the Design Professional. The Design Professional shall furnish the Owner, at no additional cost, three bound sets of specifications, complete with all addenda and authorized Change Orders, Orders and the following sets of Contract Drawings:
(a) : One set of full-size reproducible documents;
(b) , Three sets of full-size blue or black line prints; and
(c) Electronic , and Digital media (CD-ROM including CADD) CADD files in PDF formatFormat, Autodesk DWF formatAutoCad, Autoview or other electronic media approved by the Owner. equal Based upon additional information provided by the ContractorCM/GC, the Record Drawings and Final Documents shall show the Design Professional’s understanding of the locations of all utility lines and shall be altered to conform to all changes made in the building during its construction. The Design Professional shall furnish additional copies of the aforesaid documents or reproducible documents as requested by Owner, for which the Owner shall pay the actual cost of reproduction.
Appears in 6 contracts
Samples: Design Professional Services Contract, Design Professional Services Contract, Design Professional Services Contract
Record Drawings and Final Documents. The Design Professional shall, upon final completion of the Project, revise the Bidding Documents based upon documents incorporated by Change Orders, additional sketches, field changes, answered RFI’s issued by the Design Professional, and marked-up documents provided by the Contractor to show the Project “as built.” The Design Professional shall furnish and deliver the Record Drawings to the Owner after the entire work is completed and not later than sixty calendar days after execution of its Certificate of Final Completion. Record Drawings and Final Documents shall reflect all changes caused by addenda, field changes, Change Orders, or observed changes by the Design Professional, the Contractor, or Subcontractors. The Design Professional shall furnish the Owner, at no additional cost, three bound sets of specifications, complete with all addenda and authorized Change Orders, and the following sets of Contract Drawings:
(a) : One set of full-size reproducible documents;
(b) ; Three sets of full-size blue or black line prints; and
(c) Electronic and Digital media (CD-ROM including CADD) CADD files in PDF formatFormat, Autodesk DWF formatAutoCad, Autoview or other electronic media approved by the Owner. equal Based upon additional information provided by the Contractor, the Record Drawings and Final Documents shall show the Design Professional’s understanding of the locations of all utility lines and shall be altered to conform to all changes made in the building during its construction. The Design Professional shall furnish additional copies of the aforesaid documents or reproducible documents as requested by Owner, for which the Owner shall pay the actual cost of reproduction.
Appears in 6 contracts
Samples: Design Professional Contract, Design Professional Contract, Design Professional Contract
Record Drawings and Final Documents. The Design Professional shall, upon final completion of the Project, revise the Bidding Documents based upon documents incorporated by Change Orders, additional sketches, field changes, answered RFI’s issued by the Design Professional, and marked-up documents provided by the Contractor to show the Project “as built.” The Design Professional shall furnish and deliver the Record Drawings to the Owner after the entire work is completed and not later than sixty calendar days after execution of its Certificate of Final Completion. Record Drawings and Final Documents shall reflect all changes caused by addenda, field changes, Change Orders, or observed changes by the Design Professional, the Contractor, or Subcontractors. The Design Professional shall furnish the Owner, at no additional cost, three bound sets of specifications, complete with all addenda and authorized Change Orders, and the following sets of Contract Drawings:
(a) : One set of full-size reproducible documents;
(b) ; Three sets of full-size blue or black line prints; and
(c) and Electronic media (CD-ROM including CADD) files in PDF format, Autodesk DWF format, or other electronic media approved by the Owner. Based upon additional information provided by the Contractor, the Record Drawings and Final Documents shall show the Design Professional’s understanding of the locations of all utility lines and shall be altered to conform to all changes made in the building during its construction. The Design Professional shall furnish additional copies of the aforesaid documents or reproducible documents as requested by Owner, for which the Owner shall pay the actual cost of reproduction.
Appears in 4 contracts
Samples: Design Professional Contract, Design Professional Contract, Design Professional Contract
Record Drawings and Final Documents. The Design Professional shall, upon final completion of the Project, revise the Bidding Documents original drawings and specifications based upon documents incorporated by Change Orders, additional sketches, field changes, answered RFI’s issued by the Design Professional, and marked-marked up documents provided by the Contractor Design-Builder to show the Project project “as built.” ”. The Design Professional shall furnish and deliver the Record Drawings to the Owner after the entire work is completed completed, and not later than sixty (60) calendar days after execution of its Certificate of Final Completion, the Record Drawings. (Record Drawings and Final Documents shall reflect all changes caused by addenda, field changes, Change Orders, change orders or observed changes by the Design Professional, the Contractor, Design-Builder or Subcontractorsthe subcontractor(s). The Design Professional shall furnish the Owner, at no additional cost, three bound sets of specifications, complete with all addenda and authorized Change Orders, Orders and the following sets of Contract Drawings:
(a) One set of full-size reproducible documents;,
(b) Three sets of full-size blue or black line prints; , and
(c) Electronic media (CD-ROM including CADD) files in PDF format, Autodesk DWF format, Format or Autoview Format or Autocad) or other electronic media approved by the Owner. equal Based upon additional information provided by the ContractorDesign-Builder, the Record Drawings and Final Documents shall show the Design Professional’s understanding of the locations of all utility lines and shall be altered to conform to all changes made in the building during its construction. The Design Professional shall furnish additional copies of the aforesaid documents or reproducible documents as requested by Owner, for which the Owner shall pay the actual cost of reproduction.
Appears in 2 contracts
Samples: Design Build Contract, Construction Contract
Record Drawings and Final Documents. The Design Professional shall, upon final completion of the Project, revise the Bidding Documents based upon documents incorporated by Change Orders, additional sketches, field changes, answered RFI’s issued by the Design Professional, and marked-up documents provided by the Contractor to show the Project “as built.” The Design Professional shall furnish and deliver the Record Drawings to the Owner after the entire work is completed and not later than sixty calendar days after execution of its Certificate of Final Completion. Record Drawings and Final Documents shall reflect all changes caused by addenda, field changes, Change Orders, or observed changes by the Design Professional, the Contractor, or Subcontractors. The Design Professional shall furnish the Owner, at no additional cost, three bound sets of specifications, complete with all addenda and authorized Change Orders, and the following sets of Contract Drawings:
(a) One set of full-size reproducible documents;
(b) Three sets of full-size blue or black line prints; and
(c) Electronic media (CD-ROM including CADD) files in PDF format, Autodesk DWF format, or other electronic media approved by the Owner. Based upon additional information provided by the Contractor, the Record Drawings and Final Documents shall show the Design Professional’s understanding of the locations of all utility lines and shall be altered to conform to all changes made in the building during its construction. The Design Professional shall furnish additional copies of the aforesaid documents or reproducible documents as requested by Owner, for which the Owner shall pay the actual cost of reproduction. (See Para. 4g, Contract, page Contract-2.)
Appears in 1 contract
Samples: Design Professional Contract