Review of Synchronization Tests Sample Clauses

Review of Synchronization Tests. No less than forty-five (45) Days prior to the commercial operation date of the Facility, Generator shall provide Georgia Power copies of all applicable excitation system field test results (including chart recordings and actual data points in electronic form) and field settings, including (if applicable) Power System Stabilizer test results and settings in a format that conforms to the models previously submitted with the original application data. These tests include but are not limited to excitation system open circuit step in voltage tests, and (if applicable) Power System Stabilizer gain margin and phase compensation tests. Excitation system open circuit step in voltage test response chart recordings shall be provided showing generator terminal voltage, field voltage, and field current (exciter field voltage and current for brushless excitation systems) with sufficient resolution such that the change in voltages and currents are clearly distinguishable. The excitation system open circuit step in voltage test data points corresponding to the chart recordings should also be submitted in electronic form. Georgia Power may require that Generator perform more detailed tests if there are significant differences between the excitation system open circuit step in voltage test response and the step response predicted through dynamic simulation of model data. Any problems identified as a result of changes from application data to actual field settings of the excitation system including (if applicable) Power System Stabilizers must be addressed and resolved as soon as practicable by the Generator in order for the Generator to continue to deliver power to the Interconnection Point.
AutoNDA by SimpleDocs
Review of Synchronization Tests. No less than forty-five (45) Days prior to the commercial operation date of the Facility, Generator shall provide Alabama Power copies of all applicable excitation system field test results (including chart recordings and actual data points in electronic form) and field settings, including (if applicable) Power System Stabilizer test results and settings in a format that conforms to the models previously submitted with the original application data. These tests include but are not limited to excitation system open circuit step in voltage tests, and (if applicable) Power System Stabilizer gain margin and phase compensation tests. Excitation system open circuit step in voltage test response chart recordings shall be provided showing generator terminal voltage, field voltage, and field current (exciter field voltage and current for brushless excitation systems) with sufficient resolution such that the change in voltages and currents are clearly distinguishable. The excitation system open circuit step in voltage test data points corresponding to the chart recordings should also be submitted in electronic form. Alabama Power may require that Generator perform more detailed tests if there are significant differences between the excitation system open circuit step in voltage test response and the step response predicted through dynamic simulation of model data. Any problems identified as a result of changes from application data to actual field settings of the excitation system including (if applicable) Power System Stabilizers must be addressed and resolved as soon as practicable by the Generator in order for the Generator to continue to deliver power to the Interconnection Point.
Review of Synchronization Tests. 20 SECTION 9: ADMINISTRATION CHARGE.................................................................................20
Review of Synchronization Tests after the Initial Synchronization Date, Generator shall provide Alabama Power copies of all applicable excitation system field test results (including chart recordings and actual data points in electronic form) and field settings, including (if applicable) Power System Stabilizer test results and settings in a format that conforms to the models previously submitted with the original application data. These tests include but are not limited to excitation system open circuit step in voltage tests, and (if applicable) Power System Stabilizer gain margin and phase compensation tests. Excitation system open circuit step in voltage test response chart recordings shall be provided showing generator terminal voltage, field voltage, and field current (exciter field voltage and current for brushless excitation systems) with sufficient resolution such that the change in voltages and currents are clearly distinguishable. The excitation system open circuit step in voltage test data points corresponding to the chart recordings should also be submitted in electronic form. Alabama Power may require that Generator perform more detailed tests if there are significant differences between the excitation system open circuit step in voltage test response and the step response predicted through dynamic simulation of model data. Any problems identified as a result of changes from application data to actual field settings of the excitation system including (if applicable) Power System Stabilizers must be addressed and resolved immediately by Generator in order for Generator to continue to deliver power to the Interconnection Point.
Review of Synchronization Tests. 20 SECTION 9: ADMINISTRATION CHARGE.........................................................................20

Related to Review of Synchronization Tests

  • Performance Tests Contractor shall perform Performance Tests in accordance with Section 11.2 of the Agreement and Attachment S.

  • Acceptance Testing At the time of installation of a LIS trunk group, and at no additional charge, acceptance tests will be performed to ensure that the service is operational and meets the applicable technical parameters.

  • Stability Testing Patheon may be requested to conduct stability testing on the Products in accordance with the protocols set out in the Specifications for the separate fees and during the time periods set out in Schedule C to a Product Agreement. Patheon will not make any changes to these testing protocols without prior written approval from Client. If a confirmed stability test failure occurs, Patheon will notify Client within one Business Day, after which Patheon and Client will jointly determine the proceedings and methods to be undertaken to investigate the cause of the failure, including which party will bear the cost of the investigation. Patheon will not be liable for these costs unless it has failed to perform the Manufacturing Services in accordance with the Specifications, cGMPs, and Applicable Laws. Patheon will give Client ail stability test data and results at Client’s request.

  • Review Scope The parties confirm that the Asset Representations Review is not responsible for (a) reviewing the Receivables for compliance with the representations and warranties under the Transaction Documents, except as described in this Agreement or (b) determining whether noncompliance with the representations and warranties constitutes a breach of the Eligibility Representations. For the avoidance of doubt, the parties confirm that the review is not designed to determine why an Obligor is delinquent or the creditworthiness of the Obligor, either at the time of any Asset Review or at the time of origination of the related Receivable. Further, the Asset Review is not designed to establish cause, materiality or recourse for any Test Fail (as defined in Section 3.05).

  • Testing Landlord shall have the right to conduct annual tests of the Premises to determine whether any contamination of the Premises or the Project has occurred as a result of Tenant’s use. Tenant shall be required to pay the cost of such annual test of the Premises; provided, however, that if Tenant conducts its own tests of the Premises using third party contractors and test procedures acceptable to Landlord which tests are certified to Landlord, Landlord shall accept such tests in lieu of the annual tests to be paid for by Tenant. In addition, at any time, and from time to time, prior to the expiration or earlier termination of the Term, Landlord shall have the right to conduct appropriate tests of the Premises and the Project to determine if contamination has occurred as a result of Tenant’s use of the Premises. In connection with such testing, upon the request of Landlord, Tenant shall deliver to Landlord or its consultant such non-proprietary information concerning the use of Hazardous Materials in or about the Premises by Tenant or any Tenant Party. If contamination has occurred for which Tenant is liable under this Section 30, Tenant shall pay all costs to conduct such tests. If no such contamination is found, Landlord shall pay the costs of such tests (which shall not constitute an Operating Expense). Landlord shall provide Tenant with a copy of all third party, non-confidential reports and tests of the Premises made by or on behalf of Landlord during the Term without representation or warranty and subject to a confidentiality agreement. Tenant shall, at its sole cost and expense, promptly and satisfactorily remediate any environmental conditions identified by such testing in accordance with all Environmental Requirements. Landlord’s receipt of or satisfaction with any environmental assessment in no way waives any rights which Landlord may have against Tenant.

  • Inspection and Testing Each Constructing Entity shall cause inspection and testing of the Interconnection Facilities that it constructs in accordance with the provisions of this section. The Construction Parties acknowledge and agree that inspection and testing of facilities may be undertaken as facilities are completed and need not await completion of all of the facilities that a Constructing Entity is building.

  • Commissioning Commissioning tests of the Interconnection Customer's installed equipment shall be performed pursuant to applicable codes and standards. If the Interconnection Customer is not proceeding under Section 2.3.2, the Utility must be given at least ten (10) Business Days written notice, or as otherwise mutually agreed to by the Parties, of the tests and may be present to witness the commissioning tests.