Suspended Ceiling. System Standard 2’ x 4’ Grid, 2’ x 4’ Second Look Tile by Xxxxxxxxx Xxxxxxx, White Tiles Throughout U.O.N.
Suspended Ceiling. Acoustical tile and metal grid system to be white and per building standard grid size and style. All discolored or damaged tiles to be replaced prior to tenant occupancy. Provide fire rated ceiling assemblies as required.
Suspended Ceiling. The acoustical panels are used in the suspended ceiling of the control room, office areas, canteen corridors, changing room and toilet areas. The panels are on mineral wool base. The suspended ceiling in changing room and toilet areas are moisture resistive. Other Ceiling of other areas are unpainted.
Suspended Ceiling. Acoustical Ceiling 2'x4'- Auratone except Chemical Room. 2.5 Doors: Solid Core Wood Doors with Stain and Xxxxxxx Chemical Room with Hollow Metal Door.
Suspended Ceiling. Suspension system shall be 2’ x 4’ exposed T-bar grid supported from roof structure. Ceiling tile shall be non- directional, fissured mineral fiberboard with standard white finish at all offices (Xxxxxxxxx #733 “Second Look”) at 9’0” above finished floor. Suspension system is included. Floor Coverings: Office Carpet: Style: Xxxx Design Services V (5A032) or equivalent Gauge: 1/10 Stitches Per Inch: 9.5 Production Yarn Weight: 30 oz./SY Finished Pile Thickness: 201 inches Average Density: 5,373 oz./CY Warranty: 10 year Commercial Ltd. Sheet Vinyl: Type: Classic Corlon Sheet Vinyl Flooring Width: 6 Feet Style: Seagate Reference Specification: Grade 1, Class A backing Gauge: 2.16 mm overall/1.27 mm wear/layer Load Limit: 500 psi Manufacturer: Xxxxxxxxx “Seagate” · Sheet vinyl (Xxxxxxxxx “Seagate”) in Janitors closet. · Vinyl cove base; 4” in carpeted areas; 4” in sheet vinyl and VCT areas. Painting/Finishing: · Interior drywall paint shall be a two coat, one color application; wood doors to be pre-finished maple quarter sawn veneer with clear lacquer. Miscellaneous metals receive an enamel finish. Window Coverings: · Xxxxxx Xxxxxxx color 724 Crème de la crème (pearl) Blinds on any interior relites are not included. Plumbing: · Complete and code approved domestic water and sanitary sewer systems shall be provided. · Plumbing fixtures shall be Kohler (or equal); including toilet, lavs (in countertops); faucets . Water heater; capacity as required. Drinking fountain as required by code. All fixtures to meet all applicable ADA requirements. Fire Protection: · Office areas shall have semi-recessed heads with chrome escutcheons complete per code.
Suspended Ceiling. To install "T" bar ceiling with acoustical tiles. To install insulation blanket over ceiling of: executive area boardroom cafeteria
Suspended Ceiling. Standard 2' x 4' white ceiling tile with 5/8" white T-Bar grid. Ceiling at height of ten (10) feet.
Suspended Ceiling. Suspended ceiling shall be Armstrong or equal expoxxx xxxxe T-Bar grid with 2' x 4' white fissured non-directional lay-in mineral acoustic tile.
Suspended Ceiling ceiling forming a void which may accommodate services such as electrical and data cables, fire services, airconditioning services, plumbing, or form a plenum for air delivery or return.
Suspended Ceiling. (Code: H03) Size 600 x 600 x 0,5mm thick including black Soundtex(R) acoustic fleece infill material bonded to tiles with four shallow tegular edges and OWA white powder coated finish laid on OWAconstruct, Cliq System S33 exposed demountable T24 tee suspension system including galvanised main tees and cross tees, all suspended with galvanised hangers at centres not exceeding 1200mm and all installed to manufacturer's specification. Ceiling perimeter to be finished with prepainted OWAconstruct Shadowline W-trim. OWAtecta(R) Tegular Lay-in metal ceiling tiles with perforation type Rg0701, with security mesh over grid. 3 Ceilings suspended not exceeding 1m below wooden roof trusses m2 22 4 Ceilings suspended exceeding 1m and not exceeding 2m below wooden roof trusses m2 13 (Code: H05) Flush plaster gypsum or Magna Board ceiling fixed to concealed suspended tee system skimmed and prepared to receive 2 coats quality PVA paint, with security mesh over grid. 5 Ceilings suspended not exceeding 1m below wooden roof trusses m2 48 (Code: H06) Remove any mould release agent using clean water. Surface to be dry, sound and clean and cured for a minimum of 28 days, with a moisture content of 5% or less. Prime with one coat Plascon Professional Plaster Primer (PP 700) or Dulux TRade Plaster Primer (T1011) with an overcoating time of 18 hours and finish with two coats Plascon Professional Superior Low Sheen (PEM 1000) or Dulux Pearlglo Water Clean-Up (D40) with 4 hours drying time between coats.